- Secondary care >
- Orthopedic surgery >
- Bone plate >
- Stryker
Stryker bone plates
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Length: 94, 122 mm
Number of holes: 6, 8 unit
For fracture of clavicle Matching Screw: b3.5 Self-tapping Locking Screw; 3.5 Cortical Screw; 3.5 Cancellous Screw;4.0 Cancellous Screw
Lepu Medical Technology
Length: 135, 69 mm
Number of holes: 3, 8 unit
For fracture of the lateral clavicle and dislocations of the acromioclavicular joint Matching screw: Head: 2.4/2.7 Self-tapping Locking Screw Shaft: 3.5 Self-tapping Locking Screw; 3.5 Cortical screw; 3.5 Cancellous Screw; 4.0 Cancellous Screw
Lepu Medical Technology
Length: 106, 82 mm
Number of holes: 8, 6 unit
For the reduction and fixation of the clavicle fracture; Matching Screw: 3.5 Self-tapping Locking Screw; 3.5 Cortical screw; 3.5 Cancellous Screw; 4.0 Cancellous Screw
Lepu Medical Technology
Length: 22, 72 mm
System Pre-bended plates with locking system Self-tapping and self-drilling screws 4 different screw sizes and 2 diameters Advantages Locking system in the plate Intuitive instrumentation Fixation ...
... many solutions for these injuries, including: Calcaneal Fracture Management System (Includes perimeter and percutaneous plates) 5.0/7.0 mm Compression FT Screws 4.5/6.7 mm LPS Cannulated Screws Trim-It™ Pins ...
... individually is possible. Advantages - Comprehensive plating System - Two plates and three screw styles offer distinct implant combinations - One intuitive instrument set - Thin 2 mm plate design - ...
Aesculap®
... cervical plating system. Advantages - Extremely flat plate design - Special screw design reduces the likelihood of screw "Back-Out" - Fast screw insertion due to selftapping profile - Prebent lordotic plate ...
Aesculap®
... Features - Self-locking screws - Oversized revision screws - Plate marking for easier plate size selection and placement - E-Plate (Extension to the existing ABC plate) - ...
Aesculap®
Hole diameter: 2.7, 3.5 mm
... Compression Plates (LCPs) JY/WX Tibia Fibula LCPs WX 2.7mm Forefoot Midfoot Locking Fusion Plates WX 2.5mm Micro Locking Plates Cannulated Screws, Self-tapping/Headless/Countersink Kirschner ...
Suzhou Kangli Orthopaedics Instrument
Length: 22, 30, 32, 50, 71 mm
Thickness: 1.8 mm
Number of holes: 4, 6, 8 unit
Anterior Cervical Plate-II System - Low profile design, plate thickness is 1.8mm - Unique observing window on the plate, helps checking the implant status - Screws on the coronal ...
Suzhou Kangli Orthopaedics Instrument
Number of holes: 5 unit
Usage: Fixation of lower cervical and upper thoracic spine. - - SKU - Name T6584 - KLP Laminoplasty (Single Eagle) T6583 - KLP Laminoplasty (Double Eagle) 52305 - KLP Cervical Screw 52306 - KLP Cervical Fixed Screw
Suzhou Kangli Orthopaedics Instrument
Rib Fixation System Pure titanium plate, light and biocompatible, no iron ions Minimally invasive implantation Easy to fix with special clamps designed for different parts No need to remove after surgery ▪ Applied ...
Waston medical
Number of holes: 4, 8, 6 unit
... low profile plate with locking device; screw guide system. (You could see all spine products in our new website http://spine.waston-global.com/) Advantage -Choose ficed structure according to operation needs; -Easy ...
Waston medical
Indication: Immediate lamina supporting in surgery, best maintain the canal plasty expanded; The lower dentate supporting plate provides a more stable supporting force; Arc openings provide better inclusion; Has certain ...
Waston medical
Thickness: 2.5, 3.5 mm
Number of holes: 2, 20 unit
... all ITS. plates, this system offers anatomically pre-contoured plates with polyaxial locking capabilities. Should there be a need to adapt the plates to the specific patient anatomy, ...
I.T.S.
Length: 78, 107, 106, 126, 127 mm
Thickness: 3.5, 3 mm
Number of holes: 6, 9, 11 unit
The Universal Forearm Locking Plates System is an osteosynthesis system for various forearm shaft fractures.The special feature of this implant is the free choice of screw placement. The user is able to set any desired ...
I.T.S.
Length: 109, 91, 106, 88 mm
Thickness: 3.5 mm
Number of holes: 6, 4, 8, 10 unit
... locking or non-locking screw (except compression hole). In particular the anatomical plate design as well as the pre-angled plate holes of the lateral plate version provide an optimal ...
I.T.S.
... imaging . LARGE CENTRAL WINDOW The large central window of the Mecta-C Plate: enhances the graft visibility allows proper positioning of the plate facilitates the bone growth assessment
... maintain and support the bone during wedge consolidation. The screws and plates have mechanical properties that allow rapid rehabilitation and an early restoration of support. SBM provides several ...
Length: 118, 102 mm
Thickness: 3.5 mm
345.1330340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Short,Left 345.2330340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Short,Right 345.1330440.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Long,Left 345.2330440.15 ...
Health-Joy Medical
Length: 102, 118 mm
Thickness: 3.5 mm
345.1200340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion VA-LCP(PA-TTC),Short Left 345.2200340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion VA-LCP(PA-TTC),Short Right 345.1200440.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion ...
Health-Joy Medical
... .5 Anterolateral Tibiotalar Fusion VA-LOC Plate 345.1320835.15 - Ø4.5/Ø5.5 Anterolateral Tibiotalar Fusion VA-LOC Plate(ALA-TT),Long,Left 345.2320835.15 - Ø4.5/Ø5.5 Anterolateral Tibiotalar Fusion VA-LOC ...
Health-Joy Medical
... chamfering of bone plate, lower notch, reduce soft tissue irritation 2. Compression hole design, convenient for intraoperative compression fixation and adjustment of the position of the bone ...
Wuxi Betta Medical Technology
1. anatomical design, in line with the anatomical curvature of the bone 2. low notch design, reduce the irritation of soft tissue 3. The arc design of the distal end of the bone plate ...
Wuxi Betta Medical Technology
... curvature of the bone 2. Low notch design to reduce irritation of soft tissue 3. The distal end is convenient for minimally invasive insertion and can be temporarily fixed with Kirschner wire 4. Long slotted hole, ...
Wuxi Betta Medical Technology
Length: 50, 290 mm
Number of holes: 8, 4, 2, 10, 6 unit
... generation system of trochanteric grips and cable-plates utilizes the clinically proven SuperCable® polymer cerclage system, while also providing the unique option for use of either compression or locking bone ...
Polyaxial locking plates for corrective osteotomies, revision surgeries, arthrodeses and interposition arthrodeses of the first metatarsophalangeal joint Characteristics Anatomically pre-formed plate ...
Intercus
From a surgical perspective, the plate allows for an easy posterolateral approach to the upper ankle joint and subtalar joint without affecting any major anatomical structures, less impairment of wound-healing Both joints ...
Intercus
Anatomically pre-formed plate design for right and left side High primary stability thanks to Ø 3.5 mm locking cortical screws Lower failure rate of implants thanks to locking anchoring in the early functional aftertreatment ...
Intercus
Basic and simple clavicle plates for Clavicle fracture. Have 3 types of the plate: - 3.5mm Locking Clavicle plate (for mid-shaft fracture) - 3.5mm Locking Clavicle plate, ...
TDM
... Clavicle Locking Plate and Screw) System offers multiple fixation options in a variety of configurations, including anterior plates. NewCla System has a 4 types of the plate: - ...
TDM
VA Rib Locking Plate System are designed anatomically to fit a rib shape, which minimizes intraoperative bending. VA Rib System has 4 types of the plate: - Variable Locking Rib Plate ...
TDM
Length: 106, 274 mm
Thickness: 3.5 mm
Number of holes: 3, 15 unit
Distal Medial Tibial LCP (L&R) The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon ...
SurgTech
Length: 113, 373 mm
Thickness: 5.6 mm
Number of holes: 2, 3, 15 unit
Proximal Femoral Serpentine LCP (L&R) The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based ...
SurgTech
Length: 60, 147 mm
Thickness: 3.2 mm
Number of holes: 5, 12 unit
The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon the anatomical fixation required. TC20: ...
SurgTech
Hole diameter: 3.5, 2.7 mm
Number of holes: 11, 3 unit
... compression holes in the same plate (LIVTrauma). The Distal Fibula Plates are indicated for fractures, osteotomies and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially ...
Astrolabe
Hole diameter: 3.5 mm
Number of holes: 5, 8, 10, 6 unit
The Astrolabe’s Malleolus 3,5 is indicated for distal and lateral fractures of the malleolus bone.
Astrolabe
Hole diameter: 4.5, 3.5 mm
Number of holes: 6, 20 unit
... Metaphyseal 3,5/4,5mm combines the strong fixation of fixed angle construct with the compression holes in the same plate (LIVTrauma). The Metaphyseal Plates are indicated for fractures in the metaphyseal ...
Astrolabe
Thickness: 1 mm
Number of holes: 3, 14 unit
... diseases and congenital anomalies of the hands. SPECIFICATIONS • 1.0 mm thick plates and self taping screws. • The plates are bended according to the bone’s natural shapes.
Aleda
Thickness: 1.2 mm
• The plates are bended according to the bone’s natural shapes.
Aleda
Thickness: 1.5 mm
• The plates are bended according to the bone’s natural shapes.
Aleda
Thickness: 0.8, 1.2 mm
... and variety of shapes corresponding the bone anatomy. Thickness difference and their profiles that match the anatomy allow to manage a wide range of fractures within the hand. The bevelled edges of the plates ...
ChM
Length: 49, 192 mm
... the system offers 6 types of plates: -lateralTT-Tibiotalar andTTC-Tibiotalocalcaneal plates -anterolateral TT plates - posterior TT and TTC plates -anterior minimally ...
ChM
ACJ plate is intended for stabilization of the acromioclavicular joint in fresh injuries that occurred 7 up to 10 days before. The plate may be used as an alternative, in particular, for tension band ...
ChM
The system is indicated for use in cervical fusion procedures with or without tasarimmed cervical cage systems in skeletally mature patients with degenerative disc disease (DDD) from the C2 to C7 disc. Features: Anatomical shape Wide ...
• Provide high strength with low thickness • Provide effective and simple use • Low profile (totally 2 mm) • Flexible blocking system securely to the screw
NORMMED Medical Devices
• Increase canal space • Easy-release screwdriver • Tab allows for secure positioning on the lamina • 5 plate sizes and two types of screw (Self drilling and rescue screw)
NORMMED Medical Devices
• Straight Plate ,self-locking screws, nuts and washers create a rigid fixation
NORMMED Medical Devices
Length: 140.3, 291.8 mm
Number of holes: 4, 13 unit
1. Nonunions 2. Malunions 3. Comminuted Fractures 4. Fractures in Osteopenic bone
Taeyeon Medical
Length: 106, 322 mm
Number of holes: 4, 16 unit
1. Nonunions 2. Malunions 3. Comminuted Fractures 4. Fractures in Osteopenic bone
Taeyeon Medical
Length: 79, 223, 115, 151, 187 mm
Number of holes: 8, 11, 14, 17, 20 unit
1. Nonunions 2. Malunions 3. Comminuted Fractures 4. Fractures in Osteopenic bone
Taeyeon Medical
... from 1.3dia to 2.0dia while plates have various thickness of 0.4, 0.5, 0.7, 0.8 and 1.0t. Special designed plates for orthognathics surgery can be very helpful for surgeons. -All srews are compatible ...
OSTEONIC
... surgery and orthognathic surgrey. There are 2.0 Lock/Unlock, 2.4 lock and unlock in the system. Each block has various kinds of plates to cover with mandibular surgery. And, each system can be used independantly for ...
OSTEONIC
... surgery and orthognathic surgrey. There are 2.0 Lock/Unlock, 2.4 lock and unlock in the system. Each block has various kinds of plates to cover with mandibular surgery. And, each system can be used independantly for ...
OSTEONIC
Length: 100 mm
... fracture fixation system Customisable plate for every patient by thermo forming and cutting to shape Ability to be tailored during the operation to meet the challenging anatomies Low inventory quantities of plates ...
Inion
... CPS™ is our bioabsorbable answer for cranio-maxillofacial surgery. The fixation system contains a selection of resorbable plates, meshes and screws in different shapes and sizes. The Inion CPS™ product family includes ...
Inion
Thickness: 2 mm
... double-level plates and screws with radio-opaque markers. Inion S-1™ is a CE-marked medical device (Class III), manufactured by Inion Oy. The conformity assessment was conducted by BSI The Netherlands (CE 2797). The ...
Inion
Length: 167, 87 mm
Hole diameter: 3.5, 4 mm
Number of holes: 10, 12, 14, 8 unit
... joint replacement, hip prosthesis, knee prosthesis, orthopedic implants, orthopedic prosthesis, fragment plate system, plate system, proximal locking plate, femural nail, proxim It ...
Zimed Medical
Length: 6, 14 mm
Hole diameter: 5, 6.5 mm
Open wedge ostéotomies of the medial proximal tibia are indicated for idiopathic or post-traumatic varus deformities of the proximal tibia. It is used with (2O52)05mm locking screw and (2182)06.5 Locking Cancellous screw.
Zimed Medical
Number of holes: 8, 10, 12, 14, 16 unit
Locking Proximal Medial Tibial Plate Ø 5.0 - Ø 4.5 mm screw
Zimed Medical
... Non-locking Screws Available - Anatomically Pre-contoured Plate Design - Off-set screw holes • 1.5mm, 1.8mm, 2.0mm and 2.3mm screw sizes • 0.6mm, 1.0mm, and 1.3mm plate thicknesses • Comprehensive ...
Jeil Medical Corporation
... radius fractures, providing optimal fit for all radius bones with anatomically designed low-profile plates. Design based on the actual 3D radius bone scan data, to provide the perfect ...
Jeil Medical Corporation
ARIX Clavicle Plate System The ARIX Clavicle System is indicated for the fixation of single, segmental and comminuted fractures, osteotomies, mal-unions, and non-unions of the clavicle. The ARIX Clavicle System is a ...
Jeil Medical Corporation
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining