Length: 22, 72 mm
System Pre-bended plates with locking system Self-tapping and self-drilling screws 4 different screw sizes and 2 diameters Advantages Locking system in the plate Intuitive instrumentation Fixation ...
Length: 94, 122 mm
Number of holes: 6, 8 unit
For fracture of clavicle Matching Screw: b3.5 Self-tapping Locking Screw; 3.5 Cortical Screw; 3.5 Cancellous Screw;4.0 Cancellous Screw
Lepu Medical Technology
Length: 135, 69 mm
Number of holes: 3, 8 unit
For fracture of the lateral clavicle and dislocations of the acromioclavicular joint Matching screw: Head: 2.4/2.7 Self-tapping Locking Screw Shaft: 3.5 Self-tapping Locking Screw; 3.5 Cortical screw; 3.5 Cancellous Screw; 4.0 Cancellous Screw
Lepu Medical Technology
Length: 106, 82 mm
Number of holes: 8, 6 unit
For the reduction and fixation of the clavicle fracture; Matching Screw: 3.5 Self-tapping Locking Screw; 3.5 Cortical screw; 3.5 Cancellous Screw; 4.0 Cancellous Screw
Lepu Medical Technology
... individually is possible. Advantages - Comprehensive plating System - Two plates and three screw styles offer distinct implant combinations - One intuitive instrument set - Thin 2 mm plate design - ...
Aesculap®
... cervical plating system. Advantages - Extremely flat plate design - Special screw design reduces the likelihood of screw "Back-Out" - Fast screw insertion due to selftapping profile - Prebent lordotic plate ...
Aesculap®
... Features - Self-locking screws - Oversized revision screws - Plate marking for easier plate size selection and placement - E-Plate (Extension to the existing ABC plate) - ...
Aesculap®
Rib Fixation System Pure titanium plate, light and biocompatible, no iron ions Minimally invasive implantation Easy to fix with special clamps designed for different parts No need to remove after surgery ▪ Applied ...
Waston medical
Number of holes: 4, 8, 6 unit
... low profile plate with locking device; screw guide system. (You could see all spine products in our new website http://spine.waston-global.com/) Advantage -Choose ficed structure according to operation needs; -Easy ...
Waston medical
Indication: Immediate lamina supporting in surgery, best maintain the canal plasty expanded; The lower dentate supporting plate provides a more stable supporting force; Arc openings provide better inclusion; Has certain ...
Waston medical
... imaging . LARGE CENTRAL WINDOW The large central window of the Mecta-C Plate: enhances the graft visibility allows proper positioning of the plate facilitates the bone growth assessment
... maintain and support the bone during wedge consolidation. The screws and plates have mechanical properties that allow rapid rehabilitation and an early restoration of support. SBM provides several ...
Length: 106, 274 mm
Thickness: 3.5 mm
Number of holes: 3, 15 unit
Distal Medial Tibial LCP (L&R) The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon ...
SurgTech
Length: 113, 373 mm
Thickness: 5.6 mm
Number of holes: 2, 3, 15 unit
Proximal Femoral Serpentine LCP (L&R) The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based ...
SurgTech
Length: 60, 147 mm
Thickness: 3.2 mm
Number of holes: 5, 12 unit
The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon the anatomical fixation required. TC20: ...
SurgTech
Basic and simple clavicle plates for Clavicle fracture. Have 3 types of the plate: - 3.5mm Locking Clavicle plate (for mid-shaft fracture) - 3.5mm Locking Clavicle plate, ...
TDM
... Clavicle Locking Plate and Screw) System offers multiple fixation options in a variety of configurations, including anterior plates. NewCla System has a 4 types of the plate: - ...
TDM
VA Rib Locking Plate System are designed anatomically to fit a rib shape, which minimizes intraoperative bending. VA Rib System has 4 types of the plate: - Variable Locking Rib Plate ...
TDM
Length: 118, 102 mm
Thickness: 3.5 mm
345.1330340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Short,Left 345.2330340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Short,Right 345.1330440.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Long,Left 345.2330440.15 ...
Health-Joy Medical
Length: 102, 118 mm
Thickness: 3.5 mm
345.1200340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion VA-LCP(PA-TTC),Short Left 345.2200340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion VA-LCP(PA-TTC),Short Right 345.1200440.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion ...
Health-Joy Medical
... .5 Anterolateral Tibiotalar Fusion VA-LOC Plate 345.1320835.15 - Ø4.5/Ø5.5 Anterolateral Tibiotalar Fusion VA-LOC Plate(ALA-TT),Long,Left 345.2320835.15 - Ø4.5/Ø5.5 Anterolateral Tibiotalar Fusion VA-LOC ...
Health-Joy Medical
... chamfering of bone plate, lower notch, reduce soft tissue irritation 2. Compression hole design, convenient for intraoperative compression fixation and adjustment of the position of the bone ...
Wuxi Betta Medical Technology
1. anatomical design, in line with the anatomical curvature of the bone 2. low notch design, reduce the irritation of soft tissue 3. The arc design of the distal end of the bone plate ...
Wuxi Betta Medical Technology
... curvature of the bone 2. Low notch design to reduce irritation of soft tissue 3. The distal end is convenient for minimally invasive insertion and can be temporarily fixed with Kirschner wire 4. Long slotted hole, ...
Wuxi Betta Medical Technology
Hole diameter: 3.5, 2.7 mm
Number of holes: 11, 3 unit
... compression holes in the same plate (LIVTrauma). The Distal Fibula Plates are indicated for fractures, osteotomies and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially ...
Astrolabe
Hole diameter: 3.5 mm
Number of holes: 5, 8, 10, 6 unit
The Astrolabe’s Malleolus 3,5 is indicated for distal and lateral fractures of the malleolus bone.
Astrolabe
Hole diameter: 4.5, 3.5 mm
Number of holes: 6, 20 unit
... Metaphyseal 3,5/4,5mm combines the strong fixation of fixed angle construct with the compression holes in the same plate (LIVTrauma). The Metaphyseal Plates are indicated for fractures in the metaphyseal ...
Astrolabe
Thickness: 1 mm
Number of holes: 3, 14 unit
... diseases and congenital anomalies of the hands. SPECIFICATIONS • 1.0 mm thick plates and self taping screws. • The plates are bended according to the bone’s natural shapes.
Aleda
Thickness: 1.2 mm
• The plates are bended according to the bone’s natural shapes.
Aleda
Thickness: 1.5 mm
• The plates are bended according to the bone’s natural shapes.
Aleda
Thickness: 0.8, 1.2 mm
... and variety of shapes corresponding the bone anatomy. Thickness difference and their profiles that match the anatomy allow to manage a wide range of fractures within the hand. The bevelled edges of the plates ...
ChM
Length: 49, 192 mm
... the system offers 6 types of plates: -lateralTT-Tibiotalar andTTC-Tibiotalocalcaneal plates -anterolateral TT plates - posterior TT and TTC plates -anterior minimally ...
ChM
ACJ plate is intended for stabilization of the acromioclavicular joint in fresh injuries that occurred 7 up to 10 days before. The plate may be used as an alternative, in particular, for tension band ...
ChM
The system is indicated for use in cervical fusion procedures with or without tasarimmed cervical cage systems in skeletally mature patients with degenerative disc disease (DDD) from the C2 to C7 disc. Features: Anatomical shape Wide ...
• Provide high strength with low thickness • Provide effective and simple use • Low profile (totally 2 mm) • Flexible blocking system securely to the screw
NORMMED Medical Devices
• Increase canal space • Easy-release screwdriver • Tab allows for secure positioning on the lamina • 5 plate sizes and two types of screw (Self drilling and rescue screw)
NORMMED Medical Devices
• Straight Plate ,self-locking screws, nuts and washers create a rigid fixation
NORMMED Medical Devices
Hole diameter: 2.7, 3.5 mm
... Compression Plates (LCPs) JY/WX Tibia Fibula LCPs WX 2.7mm Forefoot Midfoot Locking Fusion Plates WX 2.5mm Micro Locking Plates Cannulated Screws, Self-tapping/Headless/Countersink Kirschner ...
Suzhou Kangli Orthopaedics Instrument
Length: 22, 30, 32, 50, 71 mm
Thickness: 1.8 mm
Number of holes: 4, 6, 8 unit
Anterior Cervical Plate-II System - Low profile design, plate thickness is 1.8mm - Unique observing window on the plate, helps checking the implant status - Screws on the coronal ...
Suzhou Kangli Orthopaedics Instrument
Number of holes: 5 unit
Usage: Fixation of lower cervical and upper thoracic spine. - - SKU - Name T6584 - KLP Laminoplasty (Single Eagle) T6583 - KLP Laminoplasty (Double Eagle) 52305 - KLP Cervical Screw 52306 - KLP Cervical Fixed Screw
Suzhou Kangli Orthopaedics Instrument
... from 1.3dia to 2.0dia while plates have various thickness of 0.4, 0.5, 0.7, 0.8 and 1.0t. Special designed plates for orthognathics surgery can be very helpful for surgeons. -All srews are compatible ...
OSTEONIC
... surgery and orthognathic surgrey. There are 2.0 Lock/Unlock, 2.4 lock and unlock in the system. Each block has various kinds of plates to cover with mandibular surgery. And, each system can be used independantly for ...
OSTEONIC
... surgery and orthognathic surgrey. There are 2.0 Lock/Unlock, 2.4 lock and unlock in the system. Each block has various kinds of plates to cover with mandibular surgery. And, each system can be used independantly for ...
OSTEONIC
Length: 100 mm
... fracture fixation system Customisable plate for every patient by thermo forming and cutting to shape Ability to be tailored during the operation to meet the challenging anatomies Low inventory quantities of plates ...
Inion
... CPS™ is our bioabsorbable answer for cranio-maxillofacial surgery. The fixation system contains a selection of resorbable plates, meshes and screws in different shapes and sizes. The Inion CPS™ product family includes ...
Inion
Thickness: 2 mm
... double-level plates and screws with radio-opaque markers. Inion S-1™ is a CE-marked medical device (Class III), manufactured by Inion Oy. The conformity assessment was conducted by BSI The Netherlands (CE 2797). The ...
Inion
Length: 167, 87 mm
Hole diameter: 3.5, 4 mm
Number of holes: 10, 12, 14, 8 unit
... joint replacement, hip prosthesis, knee prosthesis, orthopedic implants, orthopedic prosthesis, fragment plate system, plate system, proximal locking plate, femural nail, proxim It ...
Zimed Medical
Length: 6, 14 mm
Hole diameter: 5, 6.5 mm
Open wedge ostéotomies of the medial proximal tibia are indicated for idiopathic or post-traumatic varus deformities of the proximal tibia. It is used with (2O52)05mm locking screw and (2182)06.5 Locking Cancellous screw.
Zimed Medical
Number of holes: 8, 10, 12, 14, 16 unit
Locking Proximal Medial Tibial Plate Ø 5.0 - Ø 4.5 mm screw
Zimed Medical
... Non-locking Screws Available - Anatomically Pre-contoured Plate Design - Off-set screw holes • 1.5mm, 1.8mm, 2.0mm and 2.3mm screw sizes • 0.6mm, 1.0mm, and 1.3mm plate thicknesses • Comprehensive ...
Jeil Medical Corporation
... radius fractures, providing optimal fit for all radius bones with anatomically designed low-profile plates. Design based on the actual 3D radius bone scan data, to provide the perfect ...
Jeil Medical Corporation
ARIX Clavicle Plate System The ARIX Clavicle System is indicated for the fixation of single, segmental and comminuted fractures, osteotomies, mal-unions, and non-unions of the clavicle. The ARIX Clavicle System is a ...
Jeil Medical Corporation
Length: 10, 22 mm
Number of holes: 4 unit
E.2S cervical plate offers an anatomic geometry adapted to short and long assemblies. It possesses a patented anti-migration system enabling 1.85 low profile. Its butterfly shape eases the intraoperative viewing. Details • ...
Number of holes: 8, 9, 6, 7, 10 unit
S-Clavicle Locking Compression Plate II - Used for clavicle shaft fracture. - Screw: 11.107.51 3.5 Locking Screw 11.105.03 3.5 Cortical Screw 11.105.20 4.0 Cancellous Screw - Instrument Set: 15001888 Samll Bone ...
Changzhou Zener Medtec
Anterior Cervical Plate-MERCURY Anatomic design-the lordotic are accod with cervical physiological structure. Ultra-low profile design-imitation to anterior vertebral tissues. Visibility window design-easier observation ...
Changzhou Zener Medtec
Number of holes: 4 unit
Laminoplasty Plate-VENUS In the posterior cervical open-door operation, it can achieve real-time lamina support function, and maximum maintain spinal canal enlarging state in laminoplasty The support piece specially ...
Changzhou Zener Medtec
Length: 90, 230 mm
Number of holes: 3, 12 unit
TRUE LOCK Proximal Humerus Anatomic Plates are indicated for fractures and fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly for patients with osteopenic bone. Proximal ...
Truemed Medical
Length: 95, 110, 125, 140 mm
Number of holes: 6, 8, 10, 12 unit
... (%5). The clavicle is the first ossified bone and the ossification center closes last. It is in the form of “S” and convex to the medial anterior and concave to the lateral anterior. Anatomical plate; ...
Truemed Medical
Length: 60, 80, 100, 120 mm
Number of holes: 6, 8, 10, 12 unit
... all fractures and approximately one third of humerus fractures Anatomical plate; right & left 4 hole option between 6-12 TRUE LOCK Distal Humerus Lateral Anatomic Plates are made of Ti6Al4V ELI ...
Truemed Medical
Shortening Healing Time Less Hospital Stays Faster Sternum Recovery Time Alleviate Patient Nociception and Other Syndromes Lower Risk of Causing Sternum Dehiscence and Facture Reliable Rigid Fixation High-end Titanium ...
Number of holes: 6 unit
Can be used for one or more segments Quite thin plate No height on the plate
... The double bended mini plates fit the anatomy of the dorsally elevated lamina The plates are low profile and they prevent tissue irritation Provides secure grasp of the implant Intraoperative conformity ...
Your suggestions for improvement:
A bone plate is generally a metal plate attached to a severely fractured bone by means of screws.
ApplicationsThese devices compress the two parts of the fractured bone together, stabilizing them and accelerating the knitting process. Each compression plate is designed for a specific bone: clavicle, calcaneus, femur, humerus, metacarpals, tibia, etc.
How to chooseChoice will of course depend on the bone requiring treatment.
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining