- Laboratory >
- Hematology >
- Flow cytometry hematology analyzer >
- Sysmex
Sysmex flow cytometry hematology analyzers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Throughput: 120, 60 p/h
Sample volume: 0.11 ml
Width: 87, 91 cm
... The Atellica HEMA 570 and 580 Analyzers are fully automated, high-volume hematology analyzers. They provide: Adaptive, scalable solutions Flexible automation connectivity is expected ...
Siemens Diagnostics
Compact and reliable hematology platform including reticulocytes by fluorescence Product Description 36 parameters, 10 reticulocyte parameters Up to 80 samples / hour Enhance productivity, quality, flexibility Increase ...
Throughput: 80 p/h
Sample volume: 0.02 ml
Weight: 56 kg
... of measurement Impedance method for WBC, RBC, PLT counting; independent Basophil channel Semiconductor-laser-based flow cytometry for white blood cells differential Colorimetric method for Hemoglobin ...
... a 5-part Auto Hematology Analyzer that delivers high productivity, better accuracy and improved patient care, without sacrificing your budget. The analyzer utilizes the power of three ...
Mindray
Reliable and accurate results is the need of time. Mispa Count is a compact 5 part differential hematology analyzer which offers cutting edge technology solutions to perfectly satisfy the quality needs ...
Throughput: 60 p/h
Weight: 26.5 kg
Length: 364 mm
... repeatability and accuracy (CV and background) Independent measurement of basophils Impedance and cyanide-free method for HGB Flow Cytometry + Triple angle laser 50,000 sample memory Dual optical ...
Throughput: 80 p/h
Sample volume: 0.02 ml
Weight: 56 kg
... (CV and background) Independent basophil measurement Impedance method for WBC, RBC and PLT, cyanide-free for HGB Flow Cytometry + Triple angle laser 1 3D scattergram, 3 2D scattergrams, 3 histograms
Throughput: 60 p/h
Sample volume: 0.02 ml
Weight: 35 kg
... Impedance method for RBC and PLT and cyanide-free colorimetry for HGB Leukocyte count obtained by laser diffraction and flow cytometry Memory for up to 200,000 samples with graphics Aperture diameter ...
Throughput: 60 p/h
Sample volume: 0.02 ml
... SCIENTIFIC® 51 offers 34 parameters, as well as Histograms and dispersograms for 5 differential parts in WBC. It combines Flow Cytometry technology with 4 angles of multidimensional Laser Light for cell ...
ALPHATEC SCIENTIFIC
Throughput: 90 p/h
Sample volume: 0.02 ml
... technological innovation in the hematological field, its design allows it to work in large diagnostic laboratories. It combines Flow Cytometry technology with 4 angles of multidimensional Laser Light ...
ALPHATEC SCIENTIFIC
Throughput: 60 p/h
Sample volume: 0.02 ml
... SCIENTIFIC® 53 offers 34 parameters, as well as Histograms and scatter grams for 5 differential parts in WBC. It combines Flow Cytometry technology with 4 angles of multidimensional Laser Light for cell ...
ALPHATEC SCIENTIFIC
Apply flurescent nucleic acid staining technology Provide accurate results of immature cells Support auto re-inspection function Two units of workstation to improve the inspection efficiency
Shenzhen Dymind Biotechnology Co., LTD
Laser scatter + Chemical dye + Flow cytometry method 5-Part differentiation, 27 parameters, including 23 reportable parameters 3 Sample mode: whole blood, capillary whole blood and pre-diluted modes Up ...
Shenzhen Dymind Biotechnology Co., LTD
One button test, continuous Auto-loading Principles Flow Cytometry (FCM) + Tri-angle laser scatter + Chemical staining + Latex-enhanced Scattering Immunoturbidimetry method 3 sample modes: whole ...
Shenzhen Dymind Biotechnology Co., LTD
Weight: 73 kg
Length: 660 mm
Width: 565 mm
... differential scattergram Eosinophils and Neutrophils scattergram 2 3-D stereograms Principles of operation: WBC/DIFF: Flow Cytometry, Laser light multi-dimensional cell classification WBC Analysis: ...
Spinreact
Throughput: 60 p/h
Sample volume: 0.02 ml
Weight: 35 kg
... Parameters: ALY#, ALY%, LIC#, LIC%, NRBC#. NRBC% 2 Histograms for RBC and PLT Principles of operation WBC/DIFF: Flow Cytometry, Semi-conductor laser light multi-dimensional cell classification Principles ...
Throughput: 60 p/h
Sample volume: 0.02 ml
Weight: 73 kg
... stereograms WBC 5-part: flow cytometry(FCM) + 4 angles laser light scatter WBC analysis: optical and impédance measurements RBC/PLT analysis: impédance method HGB test: cyanide-free reagent colorimetry RETIC ...
Throughput: 110, 100 p/h
Sample volume: 0.16 ml
Weight: 91.5 kg
... operation WBC 5-part: flow cytometry (FCM) + 4 angles laser light scatter WBC analysis: optical and impédance measurements RBC/PLT analysis: impédance method HGB test: cyanide-free reagent colorimetry RETIC ...
Throughput: 60 p/h
Sample volume: 0.016, 0.02 ml
... generation 5-diff, hematology analyzer. It is a product encompassing the latest technology in optics, automation, mechanics and biology. • Storing 100000 samples with all parameters,scattergram and ...
Throughput: 90 p/h
Sample volume: 0.02 ml
Weight: 57.5 kg
... différentiation and pathological sample flag. Advanced Flow Cytometry 2D-Scattergrams Distinct Diff 3D-Scattergrams SPECIFICATIONS Cyanide free colorimetry for HGB test Laser-based flow ...
Throughput: 100 p/h
Sample volume: 0.02, 0.03, 0.035 ml
Weight: 100 kg
... Semi-conductor-based Laser Scattering Technology Fluorescence Method Flow Cytometry SPECIFICATIONS Principles - CBC+DIFF/RET: Semi-conductor Laser scattering & Fluorescent method & Flow ...
Throughput: 100, 110 p/h
Sample volume: 0.16 ml
Weight: 70 kg
PKL PPC 1100H Auto Hematology Analyzer uses helium- neon laser for the flow cytometry system. Through calculations of different angles via laser scatters, the instrument ...
Throughput: 60 p/h
Sample volume: 0.02 ml
Weight: 73 kg
PKL PPC 1200H uses semi-conductor laser for the flow cytometry system. Through calculations of different angles via laser scatters, the instrument provides complete analysis including cell size,granularity ...
Throughput: 100 p/h
Sample volume: 0.088 ml
... compromise on turnaround time. Reagent management is simple too – if you want we can integrate your reagents in the optional analyser wagon. The XN-1000 can be equipped with all the available diagnostic applications. ...
Sysmex Europe
Throughput: 150 p/h
Flow cytometry + Nucleic acid fluorescence staining technology Outperforming ,6-Part-Diff, hematology analyzer 44 reportable parameters and 59 research parameters New ...
Guilin Urit Electronic Group Co.,Ltd
Throughput: 51 p/h - 60 p/h
Sample volume: 0.02 ml - 0.33 ml
Weight: 60 kg
... Complete hematology solution Main features: Easy maintenance Ability to adjust the sensitivity of abnormal cell alarms Smart alarms User friendly Technical specifications Sistema de medición Methodology Flow ...
Throughput: 60 p/h
Sample volume: 0.038 ml
Weight: 9.4 kg
... differential hematology analyzer that sets new standards in terms of features, functions, and style. This iconic laboratory device combines cutting edge technology with a fresh and elegant design. The ...
Throughput: 60 p/h
Sample volume: 0.015 ml
Weight: 21 kg
BHA 5000 Automatic Hematology Analyzer uses Laser based flow cytometry to count white blood cells in blood sample, uses electrical impedance to count red blood cells ...
Microfluidic technology - Compact design: small size and processed a large 10'' full-color LCD touchscreen - Only 3 reagents: diluent, lyse and cleaner - Minimal maintenance - Low processed simple volumen: 2 x 1.2 uL whole blood - ...
Throughput: 90, 80 p/h
Support vein whole blood,peripheral whole blood and pre-dilute blood. Patent flow cytometry détection liquid road system and Flow Cytometry method. Provide 3 histograms, ...
Throughput: 60 p/h
Sample volume: 0.02 ml
Weight: 35 kg
... from Neomedica in the field of hematology which has gained great attention from the date of its launching and which has already found its way on many markets. As one of the closed systems currently in our offer, this ...
Throughput: 60 p/h
Sample volume: 0.02, 0.01 ml
WBC, RBC, HGB, MCHC, MCH, MCV, HCT RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR,P-LCC, LYM#, MlD#, GRA#, LYM%, MID%, GRA%, 3 Histograms for WBC, RBC and PLT Technical Specification Calibration Method Manual QC graph L-J Graph Carryover ...
B&E SCIENTIFIC INSTRUMENT CO.,LTD.
Throughput: 60 p/h
Weight: 35 kg
Length: 580 mm
... gram Eosinophils and Neutrophils scatter gram Principle of operation : WBC 5-part : Flow Cytometry,Semi-conductor laser light multi-dimensional cell classification WBC ...
Throughput: 60 p/h - 60 p/h
1. Shallow OEM: Customized logo/Neutral packing 2. Mid Level OEM: Customized startup interface/Customized labels/Customized language 3. Deep OEM: Customized packing Customized software interface: Different color match the front ...
Throughput: 60 p/h
Sample volume: 0.01 ml - 0.02 ml
Weight: 53 kg
This 5-part auto hematology analyzer is applicable for detecting the parameters of WBC, RBC, PLT, HGB, etc. (see Section 3.2. Parameters for details) in anticoagulated venous whole blood or capillary ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining