- Secondary care >
- Orthopedic surgery >
- Acetabular prosthesis
Acetabular prostheses
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Spec. - A Liner Spec. 38 - 38/22 40 - 40/22 42 - 42/28-8D 44 - 44/28-8D 46 - 46/28-8D 48 - 48/28-8D 50 - 50/28-8D 52 - 52/28-8D 54 - ...
Size - Femoral Canal Broach - Changeable Femoral Head Ф40/28 - 40 - Ф28 Ф42/28 - 42 - Ф28 Ф44/28 ...
Plasmafit® Acetabular Cup System Your solution within the Plasmafit® Family Feel the grip. Get the fit. The Plasmafit® acetabular system features and combines several important elements for cementless ...
Aesculap®
Plasmacup® Acetabular Cup System High primary stability and a low friction bearing surface The Plasmacup® acetabular cup system features and combines several important elements for cementless orthopaedic ...
Aesculap®
Screw Cup SC® Acetabular Cup System Cementless screw cup system with polyethylene or ceramic inserts Thin thread flanks and large pitches give more solid bone lamellae. Especially the combination of large thread distances ...
Aesculap®
ESCALADE® ACETABULAR SHELL The Escalade Acetabular Shell was designed to maximize range of motion capabilites. The enhanced instrument offering accommodates less invasive surgical approaches. Designed ...
LEGEND® ACETABULAR SHELL The Legend Acetabular Shell is Ortho Development’s newest acetabular solution featuring a comprehensive range of sizes and options. The 3D porous coating structure, ...
Acetabular cup diameter: 42 mm - 64 mm
Femoral head diameter: 22 mm - 40 mm
Over the years hip arthroplasty has had to adapt to patients living longer and a greater variety of needs. Stability, load, stress distribution and respect for anatomic structures are critical to the success of any press-fit cup implantation. The ...
Medacta
Acetabular cup diameter: 46 mm - 64 mm
Femoral head diameter: 22 mm - 28 mm
The Versafitcup Double Mobility is based on the original Dual Mobility design developed by Prof. Bousquet and the Medical School of St. Etienne, France, back in 1976.With more than 30 years of successful clinical history this concept ...
Medacta
Acetabular cup diameter: 42 mm - 76 mm
Mpact System is a comprehensive hemispherical cup platform featuring different shell and liner designs and materials allowing for efficiently treating the majority of the clinical cases from primary to revision surgeries, according to ...
Medacta
Acetabular cup diameter: 28 mm - 36 mm
... ceramic ; the plate does not rest on the liner. Since the impaction plate is smaller than the cup's diameter, the edge of the implant is still visible intraoperatively. Fixation on rim of cup. Material: Polycarbonate. The ...
Amplitude Surgical
Femoral stem length: 42, 64 mm
Femoral head diameter: 22.2 mm - 28 mm
Range of cylindrico-spherical dual mobility cups. Dual mobility concept implies that the liner moves within the metal cup and the femoral head moves within the liner; this increases the joint's stability and reduces wear. It keeps fundamental ...
Amplitude Surgical
Femoral head diameter: 22.2 mm - 28 mm
Dual mobility implies that the liner moves within the metal cup and the femoral head moves within the liner; this increases the joint's stability and reduces wear. In clinical use since 2000. Cementless hemispherical cup with flattened ...
Amplitude Surgical
Acetabular cup diameter: 46 mm - 68 mm
Dual Mobility implants are designed to provide greater security against luxation and can help ensure optimum patient care. The Dual Mobility BioBall® MaxiMotion™ Cup is the perfect addition to the BioBall® Systems. In combination with ...
Acetabular cup diameter: 44 mm - 70 mm
... acetabulum has an enlarged surface to ensure additional bone contact and thus anchor in the acetabulum more effectively. EpiCup® acetabular cups are combined with Standard or High Wall XPE inlays, which are anchored into ...
Acetabular cup diameter: 44 mm - 62 mm
... When the cup is implanted, the cutting teeth create a female thread in the surrounding bone tissue and thus ensure a secure implant fit. A polar threaded bore provides access to the natural acetabulum, thus allowing the ...
Acetabular cup diameter: 38 mm - 52 mm
Femoral head diameter: 44 mm - 62 mm
1. Hemispherical in shape with an exterior of Titanium alloy material. 2. Cluster hole design for the insertion of acetabular screws. 3. Coatings available both in HA and TPS to enhance bony impaction. 4. Scallop design ...
• All implants are coated with a titanium plasma+HA coating. • Polished inner surface to minimize backside wear. • Three hole hemispherical shell. • Enhanced scratch-fit feel and enhanced initial fixation.
• Cross linked polyethylene (XLPE) material. • Double locking mechanism. • Liner ears prevent rotation.
Acetabular Cup Poros Coated (Cementless) used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Acetabular Screw Acetabular Liner (10°) Cement ...
Femoral stem length: 13.5, 7.5 mm
Acetabular cup diameter: 42 mm - 62 mm
Femoral head diameter: 22 mm - 28 mm
Acetabular Cup (Cemented) (10°) used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Femoral Stem Dual Coated (Cementless) Femoral Stem (Cemented) Calcar Replacement ...
Acetabular cup diameter: 42 mm - 66 mm
... cemented, tripod and reconstruction. details FIXE version • Hemispherical acetabular cup range made of Titanium and dual coating: Titanium spray and HAP • Acetabular cups featuring 3 screw holes ...
Acetabular cup diameter: 42 mm - 68 mm
... reduce soft tissue irritation that can lead to patient dissatisfaction. Dynacup™ One-C Dynacup One-C is a cementless acetabular shell with pre-assembled ceramic liner designed for stability, performance and versatility ...
Corin
... versatility. Flexibility in screw orientation to allow for personalised screw placement. Preassembled occluders prevent implant to bone fluid pathways.
Corin
The MobiliT Cup has been designed for dislocation avoidance and shell stability. The MobiliT Cup includes a stainless steel shell, a dual mobility poly insert and either a CoCr or Ceramic head. Shell and insert design The featured ...
Corin
Acetabular cup diameter: 44 mm - 74 mm
Enhanced 60' ROM resists the impingement to the UHMWPE locking ring. Acetabular Component of Bencox Hip System is coated using plasma spray method. The microporous pure titanium coating with more than 30% porosity leads ...
Corentec
Acetabular cup diameter: 38 mm - 50 mm
Femoral head diameter: 22 mm - 28 mm
Enhanced 60' ROM resists the impingement to the UHMWPE locking ring. Proportional Eccentricity Multipolarity is achieved via multiple offsets within the system as cup sizes increase, the amount of eccentricity increases. Provides ...
Corentec
Enhanced Stability Enhanced Technology Secure Locking Mechanism The patented locking mechanism allows for secure fixation of the cup and liner with excellent resistance to push-out, rotation and tilting. Cup and ceramic insert ...
Corentec
Acetabular cup diameter: 40 mm - 68 mm
Femoral head diameter: 22 mm - 40 mm
QUARTER® is a new and comprehensive anthropometric acetabular system compatible with total hip replacement and a wide range of circumduction consisting of the following elements: Quarter Cup Material: Titanium Alloy ...
Acetabular cup diameter: 44 mm - 58 mm
... maximum preservation of bone stock and guarantees uniform load distribution to the bone thanks to the close contact with the acetabular bone of less than 0.5 mm. These are cemented cups, meaning that the convex external ...
Acetabular cup diameter: 41 mm - 63 mm
The Zimmer Biomet Trabecular Metal Acetabular Revision System (TMARS) combines clinically proven Trabecular Metal Technology with the ability to tailor individualised solutions for each patient. From simple to complex ...
The R3◊ Acetabular System combined with our portfolio of hip stems provides an advanced hip replacement system with: Wide range of advanced bearing options Excellent primary stability Flexible instrumentation Address ...
... distance, and reduce the risk of dislocation. The large diameter mobile liner is 6 mm smaller than the outer diameter of the acetabular cup Range of Motion The dynamic mechanism of a 3rd bearing allows the activation ...
Depuy Synthes
... been demonstrated to significantly reduce oxidation and long-term wear LARGEST EFFECTIVE HEAD FORAGIVEN CUPSIZE EMPOWR Acetabular™ cups share fewer mner diameters as their sizes progress, allowing for larger assembled ...
Djo Surgical
Acetabular Shell Systems Feel confident you can meet the needs of each patient with the versatility of the Trident Acetabular Shell offerings, all of which can be used with Stryker’s advanced bearing ...
Femoral head diameter: 28 mm - 44 mm
... between wear reduction and material strength. Lower wear means less chance for particle-induced osteolysis and subsequent implant loosening. Melt-annealed for consistent material properties over time. If not removed, ...
Enovis™
Seamlessly integrated with the Alteon® Platform system, the Alteon Cup is beauty refined. This acetabular system provides multiple cup implant configurations and bearing options which can be used for ...
Exactech
Acetabular cup diameter: 44 mm - 60 mm
Femoral head diameter: 29.5 mm - 41 mm
Acetabular Cup System
Acetabular cup diameter: 36 mm - 50 mm
... successful implant systems and a range of fixation concepts, together with state-of-the-art material and coating technologies, have gone into the development of this new acetabular cup system. The result ...
Waldemar Link
Acetabular cup diameter: 22 mm - 44 mm
MicroPort Orthopedics acetabular cup systems have established clinical heritage built on over 25 years of clinical presence. The Prime acetabular cup system is the next step in the evolution of the ...
Acetabular cup diameter: 28 mm - 40 mm
Femoral head diameter: 44 mm - 70 mm
... ’ for initial stability. Multiple liner and head options The universal locking mechanism design allows for multiple acetabular liner options including XPE (Highly Crosslinked Polyethylene) and E-XPE (Vitamin E ...
... binding strength between the prosthesis and cement; 2.Imported ultra-high molecular weight polyethylene material with strong anti-wear ability; 3.The acetabulum indicating ring makes it easier to observe the prosthesis ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining