- Orthopedic surgery >
- Traumatology >
- Osteotomy plate
Osteotomy plates
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

ContourLock HTO Plate, Straight Wedge, Left, 3 mm - AR-13710-03.0 Arthrex offers a variety of stainless steel and titanium plate and screw systems including the revolutionary iBalance HTO PEEK implant ...

OTIS-C-PLUS plates have been designed for Opening Wedge High Tibial Osteotomies (OWHTO). Concept OTIS-C-PLUS plates are low-profile locking osteosynthesis, paticularly well suited for ...

OTIS-F plates have been designed for distal femoral osteotomies. Concept Versatile, OTIS-F is suitable for opening as well as closing osteotomies, within a medial or lateral approach. ...

... supramalleolar. • One plate type for both left and right. Anterior SMO Plate • The anterior SMO plate is used for the anterior approach of supramalleolar osteotomy. • ...

ARIX Wrist System - 2.8 Ulna Osteotomy Locking Plate Characteristics Application: for fractures and osteotomies, in particular for the ulna. Strength : Minimal Soft Tissue Irritation : ...

... Cannulated Screw & Cannulated Headless Screw System - 4.5/6.0 Cannulated Screw System ARIX FOOT Locking Plate System - 2.8/3.5 Locking Plate System


Locking Plate, Hallux Valgus 26.26.35.27002 Locking Plate, Hallux Valgus, Small 26.26.35.27003 Locking Plate, Hallux Valgus, Medium 26.26.35.27004 Locking Plate, Hallux ...


Proximal plate, latéral side for tibia for screw 04,5 and 6,5 mm

Features of FlexitSystem implants • Titanium plates for more fatigue resistance and twice as elastic as stainless steel • Limited invasiveness with minimum thickness (3mm), screw heads buried in the plate ...

Features of FlexitSystem implants • Titanium plates for more fatigue resistance and twice as elastic as stainless steel • Limited invasiveness with minimum thickness (3mm), screw heads buried in the plate ...

Features of FlexitSystem implants • Titanium plates for more fatigue resistance and twice as elastic as stainless steel • Limited invasiveness with minimum thickness (3mm), screw heads buried in the plate ...

... anchoring section. An angle-stable spongiosa screw is used to fix the plate to the lateralised metatarsal head. This concept allows stabilisation of the osteotomies of the frontal and transversal plane ...

Key Benefits Simple, efficient proximal osteotomy technique Can achieve powerful correction Resists 1st ray shortening Solid fixed-angle locking plate for strength
Wright Medical Technology

... buttress to prevent redisplacement of a sliding type calcaneal displacement osteotomies. The low profile construct does not violate the the heel pad or disrupt the growth plate.

The ISO™ Plate with PocketLock™ Technology is a unique and creative solution for distal sliding osteotomies of the first metatarsal. The ISO Plate is a partially intraosseous plate ...

... Mini MaxLock Extreme™ MTP Plates are anatomically contoured to fit the 1st ray of smaller patients and can be used with or without PocketLock™ Technology which allows an interfragmentary screw to be utilized through the ...

... done at the place at which it is situated, that is, in the internal tibial metaphyseal region, with an open internal tibial osteotomy.

Mono-axial and polyaxial locking plates for corrective osteotomies (closed wedge) and for the treatment of fractures of the proximal tibia from lateral Indications High tibial osteotomies ...

... for calcaneus Fractures and osteotomies, the Calcaneus System 3.5 is equipped with TriLock screws and plates with the appropriate tools. There is a wide range of screw lengths available for all plates, ...

... include a range of trial implants for both 2.7mm and 3.5mm plates. Features Comprehensive range of colour coded 2.7mm and 3.5mm titanium alloy plates for multiple indications. Plates ...

... profile plates with rounded edges and tapered ends help reduce risk of soft tissue irritation Stable fixation with 2.7 mm locking and cortex screws with T8 StarDrive™ Recess Plate hole configuration allows ...
Depuy Synthes

... mm and 2 blocks allowing the compression of the osteotomy sites using the rack-and-pinion. Three ø3.5 mm screws located on both sides of the osteotomy site. IMPLANTS Symmetrical ulnar shortening plate ...
Newclip Technics

UOL - Ulna Osteotomy Locking Plate specially adapted to the anatomic requirements after shortening osteotomy of the distal ulna Impaction syndrome of the ulnar wrist.
I.T.S.

... A single screwdriver Plates suitable for minor or major reconstruction All screws are compatible with all plates Ancillary equipment specific to the range Colour code for each screw ...

Features Open-wedge and closed-wedge osteotomies of the medial proximal tibia Unicompartmental medial or lateral gonarthrosis with malalignment of the proximal tibia Idiopathic or posttraumatic varus or valgus deformity ...
HankilTech Medical

The pre-shaped LOQTEQ® DFO plate 4.5 is anatomically shaped to match the femoral condyle. The plate and the incorporated LOQTEQ® technology offers the surgeon an option to compress and lock the closed ...

High Tibial Open Wedge Osteotomy is a commanly used surgical method especially for young and active patients who have Medial Osteoarthritis with pain and Varus Deformity on their knees. The aim is the acute correction ...
TST Medical Devices

For intertrochanteric femoral osteotomies

... monoaxial and polyaxial screw options and compression holes in the MTP, Utility and Lapidus Plates. Basal Osteotomy Indication : opening or closing basal osteotomies (Hallux Valgus). ...

Universal Mini Locking Plates are indicated for the treatment of fractures and osteotomies of the phalangeal, metacarpal and metatarsal bones. The plates are pre-shaped and provide excellent ...

NEE - TIBIAL OSTEOTOMY PLATES - OPENING TIBIAL OSTEOTOMY PLATES OsTfix® High tibial osteotomy plate
Your suggestions for improvement:
Receive monthly updates on this section.
Please specify:
Help us improve:
remaining