- Cervical vertebra arthrodesis plate
Cervical vertebra arthrodesis plates
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Length: 22, 72 mm
System Pre-bended plates with locking system Self-tapping and self-drilling screws 4 different screw sizes and 2 diameters Advantages Locking system in the plate Intuitive instrumentation Fixation ...
Length: 21, 80 mm
Number of holes: 8, 4 unit
Anterior Cervical Locking Fixation System (VI) Application: For anterior cervical internal fixation
... level of the patient’s cervical spine individually is possible. Advantages - Comprehensive plating System - Two plates and three screw styles offer distinct implant combinations - ...
CASPARevolution Anterior Cervical Plating Systen The semi-rigid plate and screw interface is the basic priniciple of the CASPAR Cervical Plating System which has been used world-wide ...
... Self-locking screws - Oversized revision screws - Plate marking for easier plate size selection and placement - E-Plate (Extension to the existing ABC plate) - Corpectomy ...
Length: 22, 30, 32, 50, 71 mm
Thickness: 1.8 mm
Number of holes: 4, 6, 8 unit
Anterior Cervical Plate-II System - Low profile design, plate thickness is 1.8mm - Unique observing window on the plate, helps checking the implant status - Screws ...
Number of holes: 4, 8, 6 unit
... spondylolisthesis caused by fusion failure. -Non limiting system;large viewport; visible endplate; self-taooing screw; low profile plate with locking device; screw guide system. (You could see all spine products in ...
The Mecta-C family of Cervical Interbody Fusion Cages and Anterior Plates represent a complete system to fuse and mechanically support the cervical spine in case of degenerative ...
Length: 85, 20 mm
Number of holes: 4, 8 unit
... peripheral tissues, we must ensure the plate to be stabilized firmly, without the screw migration in the long term of activity. Therefore, an antimigration mechanism must be added into cervical plate ...
... Pre-Lordosed Plate Round-edge, low profile plate and construct(2.0mm) Small stature width and profile. Optimized geometry for fit and performance(Durabilty &Fatigue strength) Surgical Versatility Semi ...
The system is indicated for use in cervical fusion procedures with or without tasarimmed cervical cage systems in skeletally mature patients with degenerative disc disease (DDD) from the C2 to C7 disc. Features: Anatomical ...
• Provide high strength with low thickness • Provide effective and simple use • Low profile (totally 2 mm) • Flexible blocking system securely to the screw
Thickness: 2 mm
Inion S-1™ anterior cervical fusion system for graft containment includes biodegradable single and double-level plates and screws with radio-opaque markers. Inion S-1™ is a CE-marked medical device (Class ...
Anterior Cervical Plate System The FlexWing Anterior Cervical Plate System is intended for anterior vertebral screw fixation of the cervical ...
Anterior Cervical Plate-MERCURY Anatomic design-the lordotic are accod with cervical physiological structure. Ultra-low profile design-imitation to anterior vertebral ...
S33 Spine Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery and it offers a wide range of plates and screw sizes. Low ...
Number of holes: 6 unit
Can be used for one or more segments Quite thin plate No height on the plate
Anterior Cervical Plate System PROCTOPUS™ Prodorth Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery ...
Length: 65, 25 mm
Number of holes: 8, 4, 6 unit
SOFEMED efficient, and mechanical tested systems for spine surgery according to European medical devices testing center.
... Description Anterior Cervical Plate I, 4 Holes, 19mm Anterior Cervical Plate I, 4 Holes, 21mm Anterior Cervical Plate I, 4 Holes, ...
... anterior cervical plate has become widely accepted when anterior spinal fusion is performed to stabilize the spine for tumor, trauma, deformity, degenerative disc disease and other forms of cervical ...
The Pyrenees Constrained Cervical Plate System offers a low-profile design. Featuring SMARTLock Technology, the system does not require an additional locking mechanism, as each screw head forms an autogenic ...
Stryker
Streamlined instrumentation accommodates the needs of the patients and surgeons. CAM locking mechanism ensures locking of screws for optimal angles Audible, tactile and visual confirmations of locking mechanism provide confidence ...
Life Spine
1.Degenerative disc disease 2.Trauma 3.Tumors 4.Deformity (defined as kyphosis, lordosis, or scoliosis) 5.Pseudarthrosis 6.Failed previous fusions A variety of implants and instrument systems are available to meet surgeons' needs ...
Double Medical Technology
anterior cervical plate that requires only one step for inserting and locking screws into place. The ASSURE®-T translational plate adopts these core benefits while allowing for graft ...
Anterior cervical discectomy and fusion (ACDF) is a type of cervical spine surgery from the front (anterior) of the neck (cervical) that often successfully addresses ...
Aspect® Anterior Cervical Plate System The Aspect® System is a simple, yet versatile anterior cervical plate system designed to meet the varying clinical needs of surgeons ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining