- Laboratory >
- Laboratory medicine >
- Gynecology test kit
Gynecology test kits
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Specificity: 85.8 % - 98.9 %
Sensitivity: 84.7 % - 97.3 %
... underlying cause of vaginitis. Our assays: Deliver Objective Results CDC- and ACOG-recommended nucleic acid amplification tests (NAATs) deliver results that are more comprehensive and higher in sensitivity and specificity versus ...
... High purity media with no contaminate leaching Lot-to-lot uniformity for consistency of reproducibility in device formats Wide range of absorbency, thickness and fiber composition Customized cutting, packaging and pretreatment Sample pads offered ...
infectious disease test kitcobas® BV/CV
... by system software.
Kit configuration and packaging
- Kit reference: KIT COBAS 5800/6800/8800 BV/CV 192T IVD (192 tests per kit).
- Product
... infections. The kit is used for in vitro qualitative detection of group B streptococci in genital secretions and rectal secretions samples. It is suitable for pregnant women who are 34 to 37 weeks of gestation. The test ...
Result display time: 70 min
... Brief
This HPV (Type 6 and 11) DNA Fluorescence Diagnostic
Kit S3017E (PCR‑Fluorescence Probing) is an in vitro nucleic acid amplification
test for detection of low‑risk HPV (type 6/11) DNA in reproductive tract ...
Sample volume: 0.025, 0.01 ml
Down's syndrome (DS), also called trisomy 21 syndrome, is a relatively common chromosomal abnormality disease in newborns. Its main symptoms include severe congenital intellectual disability and specific abnormal facial features. The disease has a severe ...
Autobio Diagnostics
Result display time: 3 min
... ·Do not open the test foil pouch until you are ready to start the test. ·The used test should be discarded according to local regulations. [ KIT CONTENTS] · Test ...
Hangzhou Singclean Medical Products
... level in the vaginal fluid, patients can be diagnosed whether have BV. This kit mainly contains bacterial neuraminidase-specific chromogenic substrate solution. When the reagent contacts neuraminidase in the sample, ...
Hangzhou Singclean Medical Products
... the color development on any of the test bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Test strip/ Test cassette/ Test ...
Hangzhou Singclean Medical Products
Sample volume: 0.05 ml
... signal, and the strength of the signal is inversely proportional to the concentration of cProg in the sample. Detailed 【 Test Purpose】 The concentration of Canine Progesterone (cProg) in serum is related to the estrus stage of the ...
Result display time: 10 min
Sample volume: 0.01 ml
This product uses fluorescence immunochromatography to quantitatively detect the content of glycocholic acid (CG) in dog/cat blood. Basic principle: T and C lines are drawn on the nitrocellulose membrane respectively, and the T line is coated with antigen ...
... is easy to interpret visually with no additional equipment required. Test components AMA Venera (cat.number 0502) 1) two-in-one tests in an envelope, 4 pcs / two-in-one tests in an envelope, 8 pcs 2) ...
Result display time: 0 min - 30 min
... based on sialidase activity test | vaginal secretion
... polyamine-based BV test — vaginal secretion
Sample volume: 0.2 ml
... in Thyroid. The kit has been designed for the quantitative determination of TSH Receptor Antibody (TRAb) in human serum. The method can be used for samples over the range of 0.08-30IU/L. Product Description TRAb detection ...
Result display time: 10 min
... is known as a "male" sex hormone,females also have testosterone,but less. This Fluorescencnt Immunoassay testosterone POCT Kit is designed for In Vitro Quantitative Detection in whole blood ,serum and plasma samples. Summary Testosterone ...
Chengdu Vacure Biotechnology Co., Ltd
... deformities, reproductive disorders, etc. are common in children. Using a fetal chromosome aneuploidy (T21, T18, T13) detection kit (semiconductor sequencing), doctors can reliably identify these conditions in unborn ...
CapitalBio Technology
Sample volume: min 18.0 ml
... room temperature. It allows, from a single sample, in addition to cytopathological exams, the processing of other molecular tests for STIs. ...
... 100% Precision: CV <5% Packing Specifications 25 tests/ kit (single tube for single test) - 25 tests/ kit (non-single tube for single test) - ...
... contamination User-friendly workflow Convenient workflow using Seegene’s automated one platform Proper patient care Accurate test results allow to quick and proper treatment Multi-Ct in a single channel Individual Ct value of ...
Result display time: 15 min
... specifications: 25 tests/box, 10 tests/box 1) TSH test card in a sealed pouch with desiccant 2) Disposable pipet 3) User manual: 1 piece/box 4) SD card: 1 piece/box 2. For Getein1600: Package ...
Getein Biotech Inc.
The reproductive system is one of the most fragile in the human body. It needs to be nurtured and protected throughout our lives. Pregnancy and fertility are prevalent factors of reproductive health. YHLO focus on several priority areas such as increasing ...
Chlamydia detection kitTM314 series
... Detection kits for Chlamydia Available in TaqMan format for analysis Professional Tech Support with Senior R&D Scientist Fast and Flexible Ordering Options (online, email, or phone) Volume Discounts Available on ...
Result display time: 5 min
Specificity: 99.9 %
Sensitivity: 99 %
... Rapid screening test for premature rupture of fetal membranes TODA AMNIODIAG 5 cassette ® is an immunochromatographic test on cassette allowing to detect the rupture of fetal membrane by highlighting the protein IGFBP-1 ...
TODA PHARMA
Result display time: 60, 15 min
Sample volume: 0.025 ml
... the CE marked version. The DRG AMH ELISA is a solid phase enzyme linked immunosorbent assay (ELISA) based on the sandwich principle. AMH has been identified as a reliable marker of ovarian reserve that can help predict ...
DRG Instruments GmbH
... The IONA® test: The advanced NIPT solution for clinical laboratories The IONA® test is the first complete CE-IVD product for labs wishing to offer their own in-house non-invasive prenatal testing (NIPT) service. The ...
... and SuperSTaR QF-PCR kits ChromoQuant QF-PCR tests for prenatal diagnostics Detection of aneuploidy in chromosomes 13, 18, 21, X and Y ChromoQuant® is CE marked for IVD use and produced according to ISO13485 IVD ...
CyberGene AB
Result display time: 15 min
... Estradiol ( E2 ) Detection Kit ( Fluorescence Immunoassay) Based on the principle of the immunochromatographic assay, is used to detect the concentration of E2 in human serum or plasma by double antibody sandwich ...
Shenzhen Zijian Biotechnology Co., Ltd.
Result display time: 15 min
Sample volume: 0.1 ml
Prolactin, also known as lactotropin, is a protein best known for its role in enabling females to produce milk. While prolactin is secreted from the anterior pituitary gland in both men and women, women have slightly higher basal level of prolactin than ...
OptiBio Co., Ltd.
Result display time: 60 min - 90 min
Specificity: 97 % - 99 %
Sensitivity: 97 % - 99 %
... This kit is used to qualitatively detect group B streptococcus nucleic acid DNA in vitro rectal swabs, vaginal swabs or rectal/vaginal mixed swabs of pregnant women with high-risk factors around 35 ~37 weeks of pregnancy, and other gestational ...
Jiangsu Macro micro-test Medical Technology
Result display time: 12, 15 min
... This test can help figure out the cause of infertility, problems with ovarian functions, menstrual abnormalities and congenital or acquired gonadotropin development disorder or infertility. About Using Reagent Detection ...
Boditech Med Inc.
Result display time: 5 min
... Technical specifications
- Product name: Carbohydrate Antigen125 (CA125) Test Kit (Homogeneous Chemiluminescence Immunoassay)
- Specification: 25 Tests/Box
- Sample type: Serum,
Poclight
Result display time: 10 min
... TR173 - Category: Rapid tests - Subcategory: Oncology - Gynecology - Pregnancy - Packaging: 20 tests per box Technical specifications / Features: - Qualitative method on feces - Reaction time: 10 minutes - ...
... 50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL Intended use: To quantitatively detect the concentration of Placental Growth Factor in human serum in vitro. Major components: Reagent ...
AUCHEER BIOTECHNOLOGY
Result display time: 3 min
... Simply Test – Pregnancy Early Detection kit detects hCG, the hormone that confirms pregnancy, in the days before your missed period. Detect pregnancy 6 days before your missed period Accurate urine ...
... For in-vitro diagnostic use. RIDA®GENE STI Mycoplasma Panel is a multiplex real-time PCR for the direct, qualitative detection of Mycoplasma hominis, Mycoplasma genitalium and Ureaplasma urealyticum/parvum from human genital swabs and urine. The RIDA®GENE ...
Result display time: 3 min - 5 min
... EASY-ONE Pregnancy Test Kit is an in vitro diagnostic reagent that allows for easy pregnancy determination by measuring hCG(human chorionic gonadotropin) in urine using the immunochromatography method Features - ...
... AT ONCE - COMBO KIT Our ovulation test kit comes with more than just pregnancy tests; it includes ovulation tests as well, so you know your exact fertility cycle without ...
... This kit is used to quantitatively detect the content of magnesium ions in human serum in vitro. Background of Clinical Indications It is used for the auxiliary diagnosis of hypermagnesemia, hypomagnesemia and other diseases; hypomagnesemia ...
... This kit adopts colloidal gold-immunochromatography assay .The test card contains: 1. Colloidal gold-labeled anti HCG monoclonal antibodies and quality control antibody complex. 2. Nitrocellulose membranes immobilized ...
... Storage Condition: Reagent kits should be stored at 2-8℃ and be used within the expiration date. After opening, R1, R2 reagents can be stored airtight at 2-8oC for up to 7 days. Do not freeze. Package Specifications:R1:1×18mL, ...
... Reagent kit is intended for detection of Gardnerella vaginalis DNA in clinical specimens by real-time PCR. The kits contain reagents for real-time PCR only. Introduction “Molgen DNA Gardnerella ...
ADALTIS
... assessment of ovarian reserve function before and after gynecological surgery, and fertility assessment before and after gynecological tumors Application Andrology, Urology, Laboratory, Outpatient, Gynecology, ...
Xiamen Biotime Biotechnology Co., Ltd.
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.