Inlet pressure: 200 bar
Output pressure: 4 bar
Height: 120 mm
Spencer PRX 05 can be directly fixed to the tank and also has a medical gas connection entrance as required by the European standards. The calibration is fixed. The pressure control of the tank (contents) ...
Flow: 1,100, 4,600 l/min
... Series PRE proportional pressure regulator is equipped with a new technology, CoilVision, which constantly monitors the operation of the solenoids in the regulator to assess their health ...
Camozzi Automation
Flow: 1,100, 4,600 l/min
Inlet pressure: 0.1 bar - 10.3 bar
... G1/8 - G1/4 - G3/8 - 1/4NPTF The Series PME proportional pressure regulator is the ideal solution for industrial applications that require accurate pressure control. This new pressure ...
Camozzi Automation
Regulator and valve ports (Single and Manifold): G1/2 Regulator: with built-in pressure gauge or G1/8 threaded ports Valve: without pressure gauge Series MX-PRO ...
Camozzi Automation
Flow: 0 l/min - 15 l/min
Inlet pressure: 10 bar - 200 bar
Output pressure: 0.5 bar - 6.2 bar
... version, a pressure outlet (G 3/8") is also available. Every Fast pressure reducer has a rotating contents indicator in an upright or space-saving design on the housing. OXYWAY Fix ...
Inlet pressure: 0 bar - 315 bar
Output pressure: 0 bar - 15 bar
Silbermann's General Purpose Pressure Regulator reduces inlet pressure from 200 to 3-12 bars.
Silbermann Technologies
Flow: 0.5 l/min - 25 l/min
Inlet pressure: 200 bar
Silbermann’s portable oxygen regulator is designed for medical use in homes, clinics, hospitals, ambulances, and virtually for all emergency needs. Our pressure regulators ...
Silbermann Technologies
Flow: 0.5 l/min - 25 l/min
Inlet pressure: 200 bar
Silbermann’s portable oxygen regulator is designed for medical use in homes, clinics, hospitals, ambulances, and virtually for all emergency needs. Our pressure regulators ...
Silbermann Technologies
Height: 13 cm
Weight: 2.6 kg
Width: 25 cm
... Simple connections for gas inlet/outlet Filtration of any excess gas Particle counter can remain on, even when gas supply is off Two models to reduce high-pressure ...
Flow: 60 l/min - 100 l/min
Height: 38 cm
Weight: 1.3 lb
... air or gas to a particle counter can defeat its flowmetering system and possibly damage the instrument. High Pressure Diffusers (HPDs) have been developed to address particle counting in compressed ...
Flow: 0 l/min - 15 l/min
Inlet pressure: 3,000 psi
Output pressure: 50 psi
Amcaremed Medical offers flexible and different connecting thread type flowmeter regulators for the cylinder. Product Detail ll of the flowmeter regulators have easily accessible ...
AMCAREMED TECHNOLOGY
Flow: 0 l/min - 15 l/min
Inlet pressure: 3,000 psi
Output pressure: 50 psi
Oxygen regulator is a decompression device for cylinder oxygen, which ensures that the export pressure remains stable when the import pressure and the outlet flow change. Mainly used ...
AMCAREMED TECHNOLOGY
Flow: 0 l/min - 15 l/min
Inlet pressure: 3,000 psi
Amcaremed Medical offer a flexible and different connecting thread type flowmeter regulators for cylinder. All of the flowmeter regulators have easily accessible flow adjustment knobs. ...
AMCAREMED TECHNOLOGY
Input connection: G5/8 RH (F) output: M16*1.5 Pressure output: O.4-0.45Mpa
Input connection: G5/8 RH (F) output: M16*1.5 Pressure output: O.4-0.45Mpa Description O2 Pressure Regulator-Single, 4Mpa, 0.4-0.45MPa-Pro
Flow: 0 l/min - 5 l/min
... negative pressure regulating valve and the negative pressure piping systems Suction plug and medical gas outlet should good compatibility, easy handing, reliable locking, ...
Flow: 0 l/min - 5 l/min
... negative pressure regulating valve and the negative pressure piping systems Suction plug and medical gas outlet should good compatibility, easy handing, reliable locking, ...
Flow: 0 l/min - 25 l/min
Inlet pressure: 34.5 bar - 206.7 bar
Weight: 0.8 g
... reading Flow specifications range from 0-25 lpm Settings of ¼, 1/2,1, 2, 3, 4, 6, 8, 10, 15, and 25 Regulator provides a gas-regulated pressure of 57 psig at 2000 psi Flow accuracy: ...
Ferno International
Flow: 220 m³/h
Inlet pressure: 0 bar - 230 bar
Output pressure: 4 bar - 8 bar
It ensures that the pressure of the medical gases needed in hospital installations is brought to the ideal values and the installation is fed. In general, it acts as a backup of the fully ...
Megasan Medical Gas Systems
Inlet pressure: 0 bar - 10 bar
Output pressure: 0 bar - 10 bar
Weight: 535 g
... these medical device is to regulate the pressure of medical gasses which are coming from gas outlets in order to become useful for other medical devices ...
Megasan Medical Gas Systems
Inlet pressure: 230 bar
Output pressure: 0 bar - 30 bar
Weight: 4.2 kg
Pressure Reducers are medical products that ensure the gas flow from a gas supply which has high pressure gasses. The required medical ...
Megasan Medical Gas Systems
Flow: 1 l/min - 15 l/min
Inlet pressure: 4.5 bar
standard: 93/42/EEC,EN ISO 10079-3:2000 connected adapter:BS/DIN/AFNOR/DISS/OHMEDA/JIS Thread: M12*1.25mm UNF9/16-28'' G3/8-19'' 6mm hose adapter capacity of humidifier: 170ml/200ml accuracy ...
Flow: 1 l/min - 15 l/min
Inlet pressure: 15 MPa
standard: 93/42/EEC,EN ISO 10079-3:2000 connected adapter:G5/8,G3/4,CGA540 capacity of humidifier: 170ml/200ml accuracy of measures: 10% of full scale operating temp: 20°C
Flow: 1 l/min - 25 l/min
Inlet pressure: 0 bar - 200 bar
Weight: 560 g - 830 g
DEHAS QualityREG pressure reducers are intended for use on pressurised gas cylinders for compressed and pressurised dissolved medical gases. They reduce the respective ...
DEHAS tapping point pressure regulators QualityREG INLINE are designed to regulate pressure differences when tapping gases from the central gas supply and maintain the ...
Inlet pressure: 0 bar - 8 bar
Output pressure: 0.1 bar - 6 bar
justable from 0.1 to 6 bar, with pressure gauge. For all non-corrosive gases – available in country-specific standards, DIN / BS / NF (AFNOR) / Carbamed / Scandinavian Standard.
A waste gas interface device must be used to reduce negative pressure (vacuum) if you are using a central medical suction system as a gas scavenger system. A common used ...
Flow: 0.2 l/min - 1 l/min
A waste gas interface device must be used to reduce negative pressure (vacuum) if you are using a central medical suction system as a gas scavenger system. A common used ...
Waste Gas Regulator with inlet and outlet hoses table version Other models are also available for existing system on table
Flow: 35 m³/h - 50 m³/h
Inlet pressure: 8 bar - 10 bar
Output pressure: 3.5 bar - 8 bar
... NIST sockets. There is a backstop under the pressure gauges to remove a damaged or uncalibrated gauge and automatically prevent gas leakage. Reduction units are supplied with pressure ...
DZ Medicale
The socket station is a medium-pressure device with backstop that allows the supply of a 2nd stage reducer, tap, or measuring instrument. It must allow delivery of the intended gas without exceeding the ...
DZ Medicale
... II-stage reducer, mounted with coupling suitable for pure gas intake, enables sensitive and precise adjustment of the pressure value needed by the user. Independently of the pure gas ...
DZ Medicale
The medical gas pressure regulator unit will be equipped at the medical gas branch pipe at each area to ensure the stable flowrate to the patient wards, ...
Output pressure: 3.5 bar - 4 bar
... with ventilator and direct oxygen supply at emergency, ICU and ambulances. GENERAL FEATURE Maximum gas supply pressure : 200 bar Pressure Gauge Range : 0- 315 bar
Inspital Medical Technology
Inlet pressure: 0 bar - 230 bar
• Stainless steel double level • Outlet connection: R 3/8 ” • Adjustable pressure: 0-10 bar Argon 1.5 bar • Stainless steel diaphragm
Inspital Medical Technology
Inlet pressure: 0 bar - 40 bar
• Line groups with body valve • Outlet Connection : R 3/8” • Adjustable Pressure : 0-10 bar & Argon 1,5 bar • Stainles diaphragm
Inspital Medical Technology
Flow: 0 l/min - 25 l/min
Height: 3.5 in
Weight: 2 lb
... oxygen regulators incorporate the most advanced regulator technology to deliver the highest level of safety, reliability, durability, and precision flow, and are backed by an industry leading LIFETIME ...
Meret
Flow: 1 l/min - 15 l/min
Pressure reducing range: 2.0 - 3.0 kg Relief valve pressure range: (3.5 kg ± 0.5 kg)
... other similar products. Two Stage Pressure Reducing Tank is cost-effective, safe and reliable. It is processed with top-quality raw materials. Under such strict production conditions, Secondary Pressure ...
... Under such strict production conditions, Secondary Pressure Relief Box for Medical Treatment is still in stock, and there is no supply chain break, which shows our seriousness. Therefore, Two Stage Pressure ...
Height: 7 cm
Width: 12 cm
... Vacuum Regulator is often used in hospital operating rooms to clean up human waste during surgery. Vacuum Regulator can adjust the pressure, convenient and quick, reduce ...
... are ensured for a long lifetime. The pressure setting is done by an adjusting screw. The use of water can be realized with pressure regulator versions without bleeder ports. These pressure ...
Kendrion Kuhnke Automation
... are ensured for a long lifetime. The pressure setting is done by an adjusting screw. The pressure regulator versions with bleeder ports can be used for pressurized air or neutral gases. ...
Kendrion Kuhnke Automation
... is used to set the pressure level. The pressure regulator versions with bleeder ports can be used for pressurized air or neutral gases. These pressure regulators ...
Kendrion Kuhnke Automation
Flow: 40 m³/h
Inlet pressure: 16 bar
Output pressure: 4.5 bar
... is a pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal ...
GCE Group
Inlet pressure: 15 bar - 200 bar
Output pressure: 4.5 bar - 8 bar
Weight: 700 g
... patient. PURE GAS AT ALL TIMES On the inlet of each model there is a sinter filter, which prevents impurities from entering the Pressure Regulator. To ensure long-term gas ...
MEDICOP medical equipment
Output pressure: 16 bar
Height: 48, 52, 70 cm
Width: 15, 19 cm
Available in simple or duplex versions, NOVAIR Medical pressure reducers come with upstream filtration and all safety and distribution accessories required. Diaphragm regulator Safety ...
Novair Oxyplus Technologies
Inlet pressure: 0 bar - 240 bar
Output pressure: 3 bar - 50 bar
... Specifications Max. inlet pressure 240 bar Outlet Pressure 3/8/10/15/25/50 bar Temperature range -20°C to +65°C Flow capacity (cv) 0.2 Burst pressure* - 300% of operating pressure Proof ...
ROTAREX MEDITEC
... position OPEN / CLOSED respectively gas flow / gas stop safety devices according to DIN EN ISO 5175 against reverse gas flow and flashbacks reduces the risk of accidents by short hose ...
WITT
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining