Myocardial infarction test kits
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Result display time: 17 min
Sample volume: 0.1 ml
... heparinized whole blood and plasma. The result obtained with the assay is used to assist in the diagnosis of acute myocardial infarction. Creatine kinase (CK) is a key enzyme of energy metabolism in muscle ...
Result display time: 17 min
Sample volume: 0.1 ml
... whole blood and plasma on the PATHFAST™ analyzer. PATHFAST™ hs-cTnI can be used as an aid in the diagnosis of acute myocardial infarction and in the risk stratification of patients presenting with acute ...
Result display time: 17 min
Sample volume: 0.1 ml
... especially in the exclusion of acute myocardial infarction. Myoglobin (Myo) is a low molecular weight, heme-protein found in both cardiac and skeletal muscle. Following myocardial necrosis ...
... onboard centrifugation) Single and ready to use TestPaks No reconstitution No warming to room temperature Reduction in reagent waste Reduction in contamination Heparinized whole blood samples Electronic QC (System ...
Siemens Diagnostics
25 tests/box, 40 tests/box, 100 tests/box Certificates: CE, SGS ISO13485, ISO9001 Matching Equipments: Solid Phase Fluorescence Immunoassay System Manufactured by Guangzhou KOFA ...
Guangzhou KOFA Biotechnology Co.,Ltd.
5 tests/box, 25 tests/box, 40 tests/box, 100 tests/box Certificates: CE, SGS ISO13485, ISO9001 Matching Equipments: Solid Phase Fluorescence Immunoassay System ...
Guangzhou KOFA Biotechnology Co.,Ltd.
5 tests/box, 25 tests/box, 40 tests/box, 100 tests/box Certificates: CE, SGS ISO13485, ISO9001 Matching Equipments: Solid Phase Fluorescence Immunoassay System ...
Guangzhou KOFA Biotechnology Co.,Ltd.
... type (MB) and mitochondrial type (MiMi), among which MB type is mainly present in myocardial cells. In myocardial infarction, creatine kinase increases within 6 hours of onset, peaks ...
... rapid tester tro rapid cardiac markers test ctni troponin rapid tni troponin i test kit Specimen - Whole Blood,Plasma,Serum Method - Colloidal Gold immune chromatographic ...
【Introduction】 Product: H-FABP Rapid test kit Specimen: Whole blood,plasma,serum Components: Individually packed test devices,Disposable pipettes, Buffer, Package insert Sensitivity: ...
hs-cTnI Detection Kit (CLIA) MYO Detection Kit (CLIA) CK-MB Detection Kit (CLIA) NT-pro-BNP Detection Kit ...
Result display time: 15 min
... Troponin I Rapid Test Cassette is a rapid chromatographic immunoassay for the qualitative detection of cardiac Tropnin I (cTnI) and its complex in human whole blood, serum or plasma. It provides an aid in the diagnosis ...
Result display time: 15 min
... CK-MB Rapid Test Cassette is a lateral flow immunoassay for the qualitative detection of creatine kinase MB (CK-MB) and its complex in human whole blood, serum or plasma. It provides an aid in the MB diagnosis of acute ...
... isoenzymes have specificity in the diagnosis of acute myocardial infarction. Combined with myocardial enzyme map, it is helpful for the diagnosis of myocardial infarction. ...
This kit is used to quantitatively detect the activity of α-hydroxybutyrate dehydrogenase in human serum in vitro. Background of Clinical Indications It is used for the auxiliary diagnosis of myocardial ...
This kit is used to quantitatively determine the content of myoglobin in human serum in vitro. Background of Clinical Indications It is used for the auxiliary diagnosis of myocardial ischemia injury, ...
Result display time: 15 min
... , providing longer detection period. Cardiac troponin I (cTnI) has high myocardial specificity and sensitivity, so it has become an ideal marker of myocardial infarction. This kit ...
Sample volume: 0.01, 0.05, 0.02 ml
... stratification of acute myocardial infarction and other diseases with myocardial injury. The main markers of myocardial injury were troponin T, troponin I, CK-MB and ...
The cTnI ELISA is intended for the quantitative determination of cardiac troponin I in human serum.
Result display time: 10 min
... 25 tests/box, 10 tests/box 1) Getein NT-proBNP test card in a sealed pouch with desiccant 2) Disposable pipet 3) Sample diluent 4) User manual:1 piece/box 5) SD card: 1 piece/box 3. ...
Getein Biotech
Result display time: 12 min
... measure blood CK-MB level on a POC level. About Using Reagent Detection Range (3 – 100 ng/ml) (3 – 100 ng/ml) Indication (Acute)myocardial infarction, Primary Coronary Syndrome In ...
Boditech Med Inc.
... diagnosis and monitoring of AIC has been a lot of reports in the literature. Mb negative help eliminate myocardial infarction. 5. Principle This test kit use double ...
Storage Condition: Reagent kits should be stored at 2-8℃ and be used within the expiration date. Thrombin reagents should be stored airtight at 2-8oC after dissolution for up to 7 days. Do not freeze. Clinical ...
Wuhan King Diagnostic Technology Co. Ltd.
Result display time: 20 min
Sample volume: 0.15, 0.1 ml
Specificity: 95, 98 %
cTnI/CK-MB/Myo Assay kit uses colloidal gold immunochromatographic method to detect Cardiac Troponin l, CK-MB and Myoglobin in human serum, plasma or whole blood, which is to diagnose acute myocardial ...
This test kit is suitable for quantitative detec- tion of D-D in human plasma, whole blood sample in vitro, which is mainly used to diag- nose venous thrombosis, disseminated intravascular coagulation, ...
Shenzhen Afkmed
Result display time: 12 min
Sample volume: 0.04 ml
... determination of Creatine Kinase MB (CK-MB) isoenzyme in serum, plasma, and whole blood. The test is used as an aid to diagnose Acute Myocardial infarction (AMI) and Acute Coronary ...
Sugentech, Inc.
CK-MB Test Kit (Dry Fluorescence Immunoassay) is intended for In-vitro quantitative measurement of CK-MB in human serum and plasma. This test is used as an aid in the clinical diagnosis, ...
Lansion Biotechnology Co., Ltd
The MYO test kit is used for clinical in vitro quantitative detection of myoglobin content in human serum, plasma or whole blood. The MB measurement is beneficial to the diagnosis of acute myocardial ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining