Description

Overview
The DxM MicroScan WalkAway system is an automated microbiology ID and antimicrobial susceptibility testing (ID/AST) platform delivering MIC-accurate detection of antimicrobial resistance. Designed for clinical and reference laboratories, the system supports high-throughput and mixed-panel workflows while reducing hands-on time and operational complexity.

ID/AST System Benefits
  • MIC-level accuracy for reliable antimicrobial susceptibility results, including detection of carbapenemase-resistant Enterobacteriaceae (CRE).
  • Enhanced detection of emerging resistance mechanisms such as ESBL, MRSA, VRSA, VISA and VRE.
  • Faster turnaround for rapid and specialty ID/AST panels to support clinical decision-making.
  • Proprietary antibiotic formulations and validated methodologies for consistent performance.
  • Automated detection of atypical results via integrated LabPro Alert EX for prompt recognition and reporting.


Laboratory Workflow and Efficiency
The system enables broad first-time reporting with fewer clinically significant drug–bug limitations, reduced need for offline testing, and configurable data outputs for actionable results. It integrates with upstream automation and identification systems to support optimized high-volume testing and simultaneous processing of conventional, rapid and specialty panels on a single platform, lowering labor and material costs.

Software and Data
LabPro Information Manager software streamlines operations with customizable workflows and reduced technologist interaction. Optional LabPro Connect enables consolidation of data across multiple instruments for epidemiology and surveillance reporting.

Product Variants (examples)
  • B1018-440 — DxM 1040 MicroScan WalkAway Instrument
  • B1018-496 — DxM 1096 MicroScan WalkAway Instrument
  • Multiple reagent caps, reagent kits and system configurations (region-specific voltage/UPS and accessory kits).


Awards & Recognition
The MicroScan WalkAway family has received industry recognition for ID/AST performance and user-reported satisfaction.

Technical specifications
  • Physical: DxM 1040 — 29" H x 38.5" W x 34" D; 376 lbs. DxM 1096 — 37" H x 38.5" W x 34" D; 410 lbs. Color: White with gray trim. Interface connector: RJ-45 carrying RS-232 protocol.
  • Power requirements: Line voltage selectable by internal jumpers: 100/120/220/230/240 VAC. Line frequency: 50/60 Hz ±5%. Line current: 9 A (nominal), 11 A (maximum) for 100/120 VAC; 4.5 A (nominal), 5.5 A (maximum) for 220/230/240 VAC. Power-loss protection with automatic restart. Heat generation: 3,400 BTU/hour.
  • Recommended laboratory environmental conditions: Operating temperature 59°F to 80.6°F. Humidity 30% to 80% RH (no condensation).
  • Safety requirements and standards: Ground impedance ≤0.1 Ω; dielectric withstand voltage: no breakdown at 1,400 VDC for one minute; leakage current <0.5 mA. Removable power cord specifications and interlocks provided. Conforms to IEC/EN/UL/CAN standards listed for laboratory equipment safety.
  • Overcurrent protection: Primary fuses F1 and F2 (IEC 5x20 mm time lag/slow blow), 250 V rated: 12 A for 100/120 V; 6.3 A for 220/230/240 V.
  • Light source (display/illumination): Tungsten-halogen lamp options listed (50 W, 12 V and 15 W variants).
  • Display: 2-line, 20-character alphanumeric vacuum fluorescence display.
  • Temperature control: Set by computer at 35°C ±1°C; incubation temperature stability ±1°C.
  • Bar code: Code 39 standard conformance.
  • Performance: Panel capacity — DxM 1040: 40 MicroScan panels (96 wells each), up to eight panel towers with five panels each; DxM 1096: 96 MicroScan panels (96 wells each), up to eight panel towers with 12 panels each. Reagent type capacity: 10 reagents total. Reagent dispense volume: 15 to 90 µL depending on reagent. Oil dispense volume: 60 to 150 µL. Operator interface: Front-panel controls and PC keyboard/monitor with LabPro software.