Safety enhanced laboratory gas burner with touch free IR-sensor and button function. Innovative technology with graphic display that thinks with you!
VersatileThe LabFlame IR can be operated with the touch-free IR-Sensor, button function or foot pedal*. For all options, different programs exist that have been developed on the basis of practical experience: flexible start-stop functions, continuous application for up to 2 hours or programs for short flame sterilization - exact to the second. When the burner is activated, the display shows the remaining burning time.
More convenience through the graphic displayThe animated and high-contrast graphic display can be easily read under all lighting conditions due to the blue background illumination. The self-explanatory, language-less symbol menu facilitates a rapid selection of all functions. Is the display not in your line of sight? Acoustic signals additionally aid the user.
Cooling time reminder for inoculation loopsThe precisely adjustable, exact to the second, cooling time reminder aids you in exactly complying with the required cooling period of inoculation loops.
Zero-pressure shut offThe zero-pressure shut-down provides additional safety at the end of work. With it the residual pressure is released from the connection hose and the gas hose's service life is increased.
Temperature regulation for heating mediaWith the new temperature regulation system and an optional temperature sensor, the laboratory gas burner becomes a temperature-control station.
Gas consumption displayNo new cartridge at hand? The new gas consumption display reminds you to have a fresh gas cartridge on hand in a timely manner.
Flexible & individual by selecting user accountThe LabFlame IR has to 2 user accounts and saves all safety settings, burning times and other parameters for individual and flexible use.
Graphic installation instructionsGraphic installation and operating instructions at the first switch-on facilitate the initial start-up.
Innovative – The DoubleClick IR-SensorThis safety function ensures that the burner can only be ignited by activating the DoubleClick IR-Sensor twice. As a result, unintentional ignition or ignition due to dropping or falling objects is virtually impossible, increasing safety considerably.
Top-off-the-Line safetyThe Safety Control System SCS© means state-of-the-art safety technology which constantly analyzes potential hazards and, if necessary, initiates safety measures, such as an interruption of the gas supply. In addition to the ignition and flame control functions and the overheating protection, the new safety package also features continuous burner head control (BHC). BHC unfailingly detects burner head clogging by liquids or solid substances and ensures the correct assembly of the burner head.
Exceptional passive safety features: A residual heat display protects against burns. The automatic unit cut-off function prevents unintentional ignition of the flame when the burner has not been ignited for a longer period.
Modern designThe unique shape is eye-catching. The low casing makes convenient working possible; the streamlined design reduces the disturbance of the air current above a clean room workbench to a minimum. The LabFlame IR is extremely space-saving. Measurements: 103 x 49 x 130 mm (w x h x d).
With the DualKnob for adjusting gas and air flow, the flame can be precisely regulated. The removable burner head can simply be dismantled into its individual components for in-depth cleaning. Clogging is no longer a problem. Spilled liquids flow off through an integrated drain, and solid substances can be effortlessly removed by opening the burner shaft.
Environment-consciousExcellent energy efficiency in accordance with the most recent standards reduces gas and power consumption. This increases the burning time when gas cartridges are used.
UniversalThe LabFlame IR Series can be operated with stationary natural gas and propane / butane gas supplies, cartridge gas or gas cylinders.
RobustFabricated entirely of stainless steel, with fireproof controls and a display, protected by heat resistant glass, the LabFlame IR can withstand extreme lab conditions.
Technical specifications- Product No.: LF.8.200.000
- Model: LabFlame IR
- Dimensions (W x H x D): 103 x 49 x 130 mm
- Material: One-piece stainless steel housing, UV resistant
- Display: Animated high-contrast graphic display with blue backlight; language-less symbol menu; acoustic signals
- Operation modes: touch-free IR sensor, button, foot pedal
- Programs: flexible start-stop, continuous operation up to 2 hours, short flame sterilization programs (timed to the second)
- Cooling time reminder: precisely adjustable, exact to the second
- Safety: zero-pressure shut-off; DoubleClick IR sensor (optional); Safety Control System (SCS) with burner-head monitoring (BHC), flame and overtemperature monitoring
- Controls: DualKnob for gas and air flow adjustment; fireproof controls; display protected by heat resistant glass
- Burner head: removable and fully dismantlable for deep cleaning
- Maintenance features: integrated drain for spilled liquids; accessible burner shaft for removal of solids
- Energy efficiency: reduced gas and power consumption; optimized for longer cartridge burning time
- Compatible gas sources: stationary natural gas, propane/butane, cartridge gas, gas cylinders
- Robustness: suitable for cleanroom benches and demanding laboratory conditions
- User accounts: 2 user accounts for saving settings and programs
LabFlame RF - Ideal for use in cleanroom workbenches and laboratories.