OverviewClass III microbiological safety cabinets provide a fully enclosed workspace separating the operator from the work by a physical barrier with mechanically attached gloves. Filtered air is supplied continuously and exhaust air is treated to prevent release of micro-organisms. Envair’s Bio 3+ range are compact, high-performance cabinets intended for total operator protection when handling biological agents up to ACDP Hazard Group 4 (subject to correct installation, operation and maintenance). The cabinets deliver internal air cleanliness to ISO 5 and EC GMP Grade A (non-unidirectional airflow) and are available in multiple sizes, configurations and fumigation options. The Bio 3/1+ model can be converted between Class III mode (for ACDP Hazard Group 4) and Class I mode (for Hazard Group 3) where required.
Key Features- Stainless steel outer construction with white polyester coated panels and polished stainless-steel work base
- Radiused internal corners and smooth surfaces for easy cleaning
- PLC-based controls for setup, operation and maintenance
- Gauntlet/glove ports with sealing covers and mechanically attached gloves
- Toughened glass hinged visor with gas struts
- Type B pass-through hatch for secure sample transfer
- Prefilter stage to extend HEPA filter life
- Integral HEPA filtration providing ISO 5 / EC GMP Grade A internal air cleanliness
- Anti-blowback damper for connection to client ducting and remote exhaust fan
- Fully alarmed systems with safety interlocks
- Built-in BMS signal outputs and auto-damper output
- Variable-speed controlled fan for optimised performance and filter life
Caractéristiques / spécifications techniques- Protection level: suitable for handling biological agents up to ACDP Hazard Group 4 (when installed and maintained correctly)
- Internal air cleanliness: ISO 5 and EC GMP Grade A (non-unidirectional airflow)
- Construction: stainless steel outer panels with white polyester coating; polished stainless-steel work base
- Filtration: integral HEPA filtration with prefilter stage
- Controls: PLC-based control system
- Operator interface: fully alarmed and safety interlocked systems
- Ports: gauntlet/glove ports with sealing covers and mechanically attached gloves
- Visor: toughened glass hinged visor with gas struts
- Pass-through: Type B pass-through hatch included
- Exhaust interface: anti-blowback damper for ducted connection to customer exhaust and remote fan
- BMS: built-in Building Management System signal outputs and auto-damper output signal
- Fan: variable-speed controlled fan for optimised performance and filter life
- Serviceability: smooth internal surfaces and radiused corners for cleaning; available fumigation options