Membrane hemofilter OCI-HF series
hemodialysispolyethersulfonepolycarbonate

Membrane hemofilter - OCI-HF series - Lepu Medical - hemodialysis / polyethersulfone / polycarbonate
Membrane hemofilter - OCI-HF series - Lepu Medical - hemodialysis / polyethersulfone / polycarbonate
Add to favorites
Compare this product

Characteristics

Filter type
membrane
Applications
hemodialysis
Material
polypropylene, polyethersulfone, polycarbonate

Description

Product Description
Suitable for use in hemodiafiltration/hemodiafiltration treatment of patients with acute or chronic renal failure. Designed for clinical renal replacement therapy where middle- and large-molecule clearance is required.

Available Surface Areas
OCI-HF series available in the following models and effective membrane surface areas: OCI-HF160 = 1.6 m2; OCI-HF170 = 1.7 m2; OCI-HF180 = 1.8 m2; OCI-HF200 = 2.0 m2; OCI-HF210 = 2.1 m2; OCI-HF220 = 2.2 m2; OCI-HF230 = 2.3 m2; OCI-HF240 = 2.4 m2; OCI-HF250 = 2.5 m2.

Product Features
  • Effective clearance of middle and large molecules
  • Safety-grade polycarbonate housing material
  • Demonstrated phosphate clearance performance
  • Optimized membrane wall design to enhance diffusive transport


Product Structure
Hollow-fiber hemodiafilter; detailed illustrative image available on the product page.

Specifications
  • Series name: HF series
  • Models: OCI-HF160, OCI-HF170, OCI-HF180, OCI-HF200, OCI-HF210, OCI-HF220, OCI-HF230, OCI-HF240, OCI-HF250
  • Surface areas (m2): 1.6 / 1.7 / 1.8 / 2.0 / 2.1 / 2.2 / 2.3 / 2.4 / 2.5
  • Ultrafiltration coefficient (mL/h·mmHg): 71 / 72 / 73 / 80 / 83 / 85 / 87 / 89 / 91 (corresponding to models above)
  • Chamber volume (mL): 100 / 107 / 112 / 123 / 126 / 130 / 133 / 135 / 141 (corresponding to models above)
  • Membrane material: Polyethersulfone (PES)
  • Housing material: Polycarbonate (PP)
  • Potting compound: Polyurethane (PU)
  • Clearance test condition: QD = 500 mL/min; clearance values provided at QB = 200 / 300 / 400 mL/min
  • Clearance — Urea (mL/min) by model: 197/280/330 · 198/282/335 · 198/285/340 · 199/288/345 · 195/288/347 · 196/289/347 · 199/290/348 · 199/291/349 · 199/292/350 (models OCI-HF160 → OCI-HF250)
  • Clearance — Creatinine (mL/min) by model: 195/262/310 · 195/266/316 · 196/269/320 · 197/273/330 · 198/273/332 · 198/275/334 · 198/280/336 · 199/282/338 · 200/283/340
  • Clearance — Phosphate (mL/min) by model: 185/245/281 · 187/250/291 · 189/255/296 · 192/260/308 · 193/262/310 · 193/264/312 · 194/266/315 · 195/268/318 · 196/272/322
  • Clearance — Vitamin B12 (mL/min) by model: 152/183/201 · 156/189/210 · 159/194/215 · 164/202/223 · 165/206/226 · 167/209/228 · 169/211/232 · 172/215/236 · 174/220/244
  • Screening coefficients: Albumin ≤ 0.01; β2‑MG = 0.85 ± 0.2; Inulin = 1.0 ± 0.1
  • Maximum TMP: 66.5 kPa / 500 mmHg
  • Operating blood flow range: 200–400 mL/min
  • Dialysate flow range: 500–800 mL/min
  • Sterilization / Shelf life: Irradiation sterilization; shelf life 3 years
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.