Characteristics

Type
climatic
Controlled parameter
temperature, humidity
Applications
laboratory
Configuration
mobile
Number of doors
2-door
Capacity

749 l
(197.9 gal)

Temperature range

Max.: 60 °C
(140 °F)

Min.: -10 °C
(14 °F)

Description

Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP – GCCP. Temperature Setting temperature range: -10 to +60 °C Working temperature range: from -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over) Working temperature range: from +10°C up to +60°C with humidity and/or light Setting accuracy temperature: 0.1 °C Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Humidity Humidity: humidity supply with distilled water from external tank by self-priming pump Humidification: humidification by hot steam generator Humidity: active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity - resolution of display 0.1 %, setting accuracy 0.5 % Control technology ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. adjustable parameters: temperature (Celsius or Fahrenheit), fan speed, relative humidity, programme time, time zones, summertime/wintertime Language setting: German, English, Spanish, French, Polish, Czech, Hungarian Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT: the process time does not start until the set temperature is reached Calibration: three freely selectable values each, temperature/humidity, for two freely selectable values CO2

Exhibitions

Meet this supplier at the following exhibition(s):

ANALYTICA 2024
ANALYTICA 2024

9-12 Apr 2024 München (Germany) Hall B2.105 - Stand Vide

  • More information
    ACHEMA 2024
    ACHEMA 2024

    10-14 Jun 2024 Frankfurt (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.