Indirect digital X-ray system NKX343
DRdigitalwith mobile table

Indirect digital X-ray system - NKX343 - Shandong Newheek Image Equipment - DR / digital / with mobile table
Indirect digital X-ray system - NKX343 - Shandong Newheek Image Equipment - DR / digital / with mobile table
Add to favorites
Compare this product

Characteristics

Technology
digital, DR, indirect digital
Features
with mobile table, without table

Description

Product Overview
NKX343 and NKX543 are UC-arm digital DR radiography systems designed for general radiographic imaging in hospitals, clinics and imaging centers. The UC-shaped bending frame provides flexible multi-angle adjustment for standing, sitting and supine examinations. Two configurations are available: a vertical standalone UC-arm for upright radiography, and a UC-arm paired with a mobile radiographic table for both recumbent and standing patients. The system integrates a high-frequency X-ray generator and a 17×17" amorphous silicon CsI flat-panel detector to deliver fast, high-definition digital images.

Main Technical Parameters
  • 1. X-ray high-frequency generator
    Supply voltage: 380V ±10%, three-phase five-wire; frequency: 50Hz ±1Hz; generator capacitance: ≥50kVA; internal resistance: ≤0.3Ω.
    Radiography ranges:
    Tube voltage: 40–125 kV (optional 150 kV), 1 kV step.
    Tube current: 10–640 mA; mA accuracy ≤±10%.
    Exposure time: 1–10000 ms.
    mAs range: 0.1–640 mAs; mAs accuracy ≤±(5%+0.2 mAs).
    APR storage: 24000 datasets.
    Auxiliary outputs: 24 VDC 300 mA, 220 VAC 5 A.
  • 2. X-ray tube assembly
    30 kW (optional 50 kW) / 125 kV (optional 150 kV); dual focus 0.6 mm / 1.2 mm; anode heat capacity: 140 kJ.
  • 3. Manual collimator
    Maximum irradiation field: 440 mm × 440 mm (SID = 100 cm).
    Light field brightness: >160 lux; illumination contrast: >4:1; lamp: 24 V / 150 W; single lighting time: 30 s.
    Focus-to-tabletop distance: 60 mm (adjustable); inherent filtration (75 kV): 1 mm Al.
  • 4. Flat panel detector
    Type: amorphous silicon with CsI scintillator.
    Imaging size: 17×17"; spatial resolution: 3.6 lp/mm; dimensions: 460 × 460 × 5 mm; panel housing: carbon fiber + engineering plastic; frame: aluminum alloy.
    A/D: 16 bit; data interface: Gigabit Ethernet; full image acquisition time: ≤3 s; detector weight: 3.2 kg; average panel weight: 300 g.
  • 5. UC-arm stand frame
    Vertical travel: 1200 mm ±20 mm; minimum ground clearance: 480 mm ±20 mm; UC-arm rotation: 0°–90°; detector rotation: -45° to +45°; SID adjustable: 1000–1800 mm.
  • 6. Mobile radiography table
    Dimensions (L×W×H): 2020 mm × 800 mm × 690 mm.
    Optional tabletop materials: density board / carbon fiber / acrylic.


Product Advantages
  • UC bending frame enables multi-position imaging for standing, sitting and supine patients.
  • High-frequency generator ensures stable output and precise exposure control for consistent radiographic results.
  • 17×17" CsI amorphous silicon detector provides rapid acquisition and high-resolution digital X-ray images.
  • Wide SID range, detector rotation and vertical travel adapt to diverse patient sizes and clinical workflows.
  • Two configuration options (standalone UC-arm or UC-arm with mobile table) suit different department layouts.
  • User-programmable APR storage (24000 datasets) improves throughput and standardizes exam protocols.


Technical Specifications
  • Model designation: NKX343 / NKX543 UC-arm Digital DR System
  • Power supply: 380V ±10%, three-phase five-wire; 50 Hz ±1 Hz
  • Generator capacitance: ≥50 kVA; internal resistance: ≤0.3 Ω
  • Tube voltage: 40–125 kV (optional 150 kV), 1 kV step
  • Tube current: 10–640 mA; accuracy ≤±10%
  • Exposure time: 1–10000 ms
  • mAs range: 0.1–640 mAs; accuracy ≤±(5%+0.2 mAs)
  • APR storage: 24000 datasets
  • X-ray tube: 30 kW (optional 50 kW) / 125 kV (optional 150 kV); dual focus 0.6 mm / 1.2 mm; anode heat capacity 140 kJ
  • Collimator field: 440 mm × 440 mm (at SID = 100 cm); light field brightness >160 lux
  • Detector: 17×17" amorphous silicon with CsI scintillator; spatial resolution 3.6 lp/mm; 16-bit A/D; Gigabit Ethernet; full acquisition ≤3 s
  • UC-arm travel: vertical 1200 mm ±20 mm; rotation 0°–90°; detector rotation -45°–+45°; SID adjustable 1000–1800 mm
  • Mobile table size: 2020 mm × 800 mm × 690 mm; tabletop options: density board / carbon fiber / acrylic
  • Auxiliary outputs: 24 VDC 300 mA, 220 VAC 5 A
  • Configuration options: standalone vertical UC-arm or UC-arm with mobile radiographic table

Catalogs

No catalogs are available for this product.

See all of Shandong Newheek Image Equipment‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.