Automatic cell imaging system CellScan/Cytoimage
laboratoryfor researchfor cell culture

Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 2
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 3
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 4
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 5
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 6
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 7
Automatic cell imaging system - CellScan/Cytoimage - Tailin - laboratory / for research / for cell culture - image - 8
Add to favorites
Compare this product

Characteristics

Operation
automatic
Applications
laboratory, for research, for cell culture, for bioprocess
Observation technique
phase contrast
Other characteristics
high-resolution, high-content, with incubator, with integrated camera, wireless

Description

Product introduction
CellScan (mobile/area-scan version) and Cytoimage (single-point version) are incubator-compatible live cell imaging systems for continuous, label-free monitoring and quantitative analysis of cell cultures. Designed for GMP environments and research labs, both systems enable remote observation, automated data capture and cloud-based storage to reduce cleanroom entries and support process control.

Features
  • Designed for sterile environments: Smooth surfaces and no dead angles, compatible with vaporized hydrogen peroxide, UV and alcohol disinfection.
  • Closed incubator operation: Devices operate inside the incubator to minimize temperature and medium disturbances and reduce contamination risk.
  • Label-free imaging: No staining required, allowing repeated observation without affecting cell viability.
  • Phase-contrast reflective illumination: Optimized light source and algorithms deliver high-contrast cell images.
  • Supports multiple container types: Same-side reflective imaging accommodates dishes, well plates, flasks and multilayer culture vessels without height limits.
  • Automated AI counting and confluence measurement: Consistent, objective cell number and confluence data to reduce operator variability (CellScan provides area statistics).
  • Cloud control and monitoring: Remote access via smartphone or tablet for real-time status and secure data backup.
  • Area scanning (CellScan only): Multi-point and full-area scanning for standard plates and custom modules to capture representative growth data.


Specifications (comparison)
  • Operating environment: Temperature 37±0.3℃; Humidity 0–99% — both models
  • Dimensions: CellScan W370×D440×H84 mm — Cytoimage W210×D225×H80 mm
  • Weight: CellScan approx. 12.25 kg — Cytoimage approx. 3.25 kg
  • Compatible containers: 90/100 mm dishes; 6-,12-,24-,48-,96-well plates; T-series flasks; multi-layer flasks — both models
  • Illumination wavelength/method: λ = 630 nm; phase-contrast reflective illumination — both models
  • Magnification: 10X — both models
  • Capture/field size: CellScan capture 100×100 mm; field 7.2×5.2 mm — Cytoimage capture 7.2×5.2 mm; field 7.2×5.2 mm
  • Image size: 2880×2064 pixels — both models
  • Sterilization resistance: Compatible with vaporized hydrogen peroxide, UV and alcohol disinfection — both models
  • Cell analysis & data: Cell confluence and automated counting, growth and doubling-time curves, image/video/CSV export (CellScan provides expanded analytics)


Applications
  • Cell therapy manufacturing and process monitoring
  • GMP sterile laboratories and cleanrooms
  • Clinical research centers and cell biology labs


Technical specifications
  • Operating environment: Temperature 37±0.3℃; Humidity 0–99%
  • Dimensions: CellScan W370×D440×H84 mm; Cytoimage W210×D225×H80 mm
  • Weight: CellScan approx. 12.25 kg; Cytoimage approx. 3.25 kg
  • Compatible containers: 90/100 mm dishes; 6-,12-,24-,48-,96-well plates; T-series culture flasks; multi-layer flasks
  • Illumination wavelength: 630 nm
  • Illumination method: Phase-contrast reflective illumination
  • Magnification: 10X
  • Capture size: CellScan 100×100 mm; Cytoimage 7.2×5.2 mm
  • Field of view: 7.2×5.2 mm
  • Image size: 2880×2064 pixels
  • Sterilization resistance: Compatible with vaporized hydrogen peroxide, UV and alcohol disinfection
  • Cell analysis: Confluence measurement and automated cell counting (CellScan)
  • Data statistics: Growth curve and doubling time curve (CellScan)
  • Data export: Image files, video files, CSV files

Exhibitions

Meet this supplier at the following exhibition(s):

CPHI China
CPHI China

16-18 Jun 2026 Shanghai (China) Hall N3 - Stand B56

  • More information
    FILTECH
    FILTECH

    30 Jun - 02 Jul 2026 Cologne (Germany) Hall 7 - Stand N21

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.