Membrane ultrafilter Vivacon® 500 ETO
for liquidsfor protein solutionslaboratory

Membrane ultrafilter - Vivacon® 500 ETO - Vivaproducts, Inc. - for liquids / for protein solutions / laboratory
Membrane ultrafilter - Vivacon® 500 ETO - Vivaproducts, Inc. - for liquids / for protein solutions / laboratory
Add to favorites
Compare this product

Characteristics

Filter type
membrane
Fluid
for liquids, for protein solutions
Applications
laboratory, centrifuge, for protein concentration, for protein purification
Material
cellulose triacetate, polycarbonate, polypropylene, silicone, regenerated cellulose
Other characteristics
sterile, single-use
Connecting diameter

11 mm
(0.43 in)

Description

Product overview
Vivacon® 500 ETO centrifugal concentrators enable rapid concentration of nucleic acids and removal of PCR primers from samples with a 0.5 ml starting volume. Concentration factors up to 50x using low‑binding Hydrosart® regenerated cellulose horizontal membranes. Compatible with microcentrifuges having fixed‑angle rotors that accept 1.5 / 2.2 ml (11 mm) conical bottom tubes (95 mm depth). Reverse spin function simplifies sample recovery. Dual‑cycle ethylene oxide (ETO) sterilization to SAL 10⁻⁶; tested free of detectable human genomic DNA by qPCR (55 cycles; detection limit 2 pg).

Applications
  • DNA rebuffering of organic extraction samples prior to sequencing.
  • Dye removal after sequencing reactions.
  • Primer removal from PCR products.
  • Plasmid concentration and clean‑up.


Performance — Vivacon® 500 for DNA
  • 2,000 MWCO — Sample size (bp): 10 — Time to concentrate up to 30x: 60 min at 20°C — Concentrate recovery: 93% — g‑force: 7,500 xg
  • 10,000 MWCO — Sample size (bp): 30 — Time: 25 min at 20°C — Recovery: 94% — g‑force: 7,500 xg
  • 30,000 MWCO — Sample size (bp): 50 — Time: 18 min at 20°C — Recovery: 88% — g‑force: 5,000 xg
  • 50,000 MWCO — Sample size (bp): 300 — Time: 18 min at 20°C — Recovery: 91% — g‑force: 3,000 xg
  • 100,000 MWCO — Sample size (bp): 600 — Time: 10 min at 20°C — Recovery: 87% — g‑force: 3,000 xg
  • 125,000 MWCO — Sample size (bp): 650 — Time: 12 min at 20°C — Recovery: 85% — g‑force: 2,000 xg
  • 125,000 MWCO — Sample size (bp): 900 — Time: 9 min at 20°C — Recovery: 94% — g‑force: 3,000 xg


Performance — Vivacon® 500 for proteins
  • 2,000 MWCO — 0.25 mg/ml cytochrome c — Time to concentrate up to 30x: 30 min at 20°C — Recovery: 95% — g‑force: 14,000 xg
  • 10,000 MWCO — 0.25 mg/ml cytochrome c — Time: 15 min at 20°C — Recovery: 92% — g‑force: 14,000 xg
  • 30,000 MWCO — 1.0 mg/ml BSA — Time: 10 min at 20°C — Recovery: 95% — g‑force: 14,000 xg
  • 50,000 MWCO — 1.0 mg/ml BSA — Time: 10 min at 20°C — Recovery: 92% — g‑force: 14,000 xg
  • 100,000 MWCO — 1.0 mg/ml bovine IgG — Time: 11 min at 20°C — Recovery: 90% — g‑force: 8,000 xg
  • 100,000 MWCO — 0.02 mg/ml porcine hematin — Time: 10 min at 20°C — Recovery: 88% — g‑force: 2,500 xg
  • 125,000 MWCO — 1.0 mg/ml bovine IgG — Time: 10 min at 20°C — Recovery: 81% — g‑force: 8,000 xg
  • 125,000 MWCO — 0.02 mg/ml porcine hematin — Time: 10 min at 20°C — Recovery: 11% — g‑force: 2,500 xg


Conversion table
  • Hydrosart® — 2 kDa — Double‑stranded nucleotide cut‑off (bp): >10
  • Hydrosart® — 10 kDa — Cut‑off: >30 bp
  • Hydrosart® — 30 kDa — Cut‑off: >50 bp
  • Hydrosart® — 50 kDa — Cut‑off: >300 bp
  • Hydrosart® — 100 kDa — Cut‑off: >600 bp
  • Cellulose Triacetate — 125 kDa — Cut‑off: >650 bp


Ordering / available variants
  • VN01H22ETO — PCR Grade, 30,000 MWCO, Hydrosart membrane, 100 per pack — $636.00
  • VN01H23ETO — PCR Grade, 30,000 MWCO, Hydrosart membrane, 500 per pack — Discontinued (order VN01H22ETO instead)
  • VN01H42ETO — PCR Grade, 100,000 MWCO, Hydrosart membrane, 100 per pack — $636.00
  • VN01H43ETO — PCR Grade, 100,000 MWCO, Hydrosart membrane, 500 per pack — Discontinued (order VN01H42ETO instead)


Technical specifications
  • Concentrator capacity (fixed angle rotor): 0.5 ml
  • Total length (concentration): 45 mm
  • Total length (backspin): 47.5 mm
  • Width: 12.4 mm
  • Active membrane area: 0.32 cm²
  • Hold‑up volume (membrane and support): <5 µl
  • Dead stop volume: 5 µl (40° rotor)
  • Body material: Polycarbonate
  • Filtrate vessel: Polypropylene
  • Back spin vial: Polypropylene
  • O‑ring: Silicone
  • Membrane (except 125,000 MWCO): Hydrosart® (regenerated cellulose)
  • Membrane (125,000 MWCO): Cellulose Triacetate
  • Required rotor type: Fixed angle (minimum rotor angle 40°)
  • Rotor cavity: Fits 1.5 / 2.2 ml (11 mm) conical bottom tubes (95 mm depth)
  • Maximum recommended speed: 5,000 xg (may be increased in some cases; see manual)
  • Sterilization / contamination control: Dual‑cycle ETO sterilization to SAL 10⁻⁶; tested for absence of detectable human genomic DNA by qPCR (55 cycles; detection limit 2 pg)