video corpo
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Electrical safety tester DFS400
loadvoltagefor external defibrillators

Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators
Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators
Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators - image - 2
Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators - image - 3
Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators - image - 4
Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators - image - 5
Electrical safety tester - DFS400 - WhaleTeq Co., Ltd - load / voltage / for external defibrillators - image - 6
Add to favorites
Compare this product

Characteristics

Tested parameter
electrical safety, load, voltage
Applications
for external defibrillators
Operating mode
automatic
Configuration
portable, benchtop, tabletop
Other characteristics
digital, USB
Weight

1.6 kg
(3.5 lb)

Width

24 cm
(9.4 in)

Height

6 cm
(2.4 in)

Description

Overview
Designed for engineers at AED/defibrillator manufacturers, the DFS400 from WhaleTeq integrates multiple testing instruments and functions into a single device. Dedicated software displays and automatically saves test data (shock waveform, energy in J, parameters and characteristic points) to build a traceable test history. The unit includes switchable built-in impedance loads to evaluate shock performance under various conditions and offers Repeatability & Reproducibility (R&R) analysis to compare multiple shock waveforms for consistency (R&R module optional).

Functions
  • Outputs shockable and non-shockable ECG signals (VF coarse/fine, VT, AF, Asystole, Normal Sinus Rhythm).
  • Measures shock waveform and energy: displays waveform, Joules, parameters and characteristic points with 4 μs sampling resolution; voltage and time cursors for detailed inspection.
  • Basic waveform output: generates Sine, Square, Triangle waveforms with adjustable BPM, frequency and amplitude; configurable ECG waveforms for basic verification.
  • Switchable loads: built-in resistances (25, 50, 75, 100, 125, 150, 175, 200 Ω) selectable via software to simulate physiological conditions.
  • Raw data playback: supports playback of ECG databases and reproduction of clinically recorded or user-defined waveforms for repeated verification.
  • Simple automated testing: 'Auto Sequence' organizes and stores frequently used test items for automated runs.
  • Shock waveform and energy analysis: R&R analysis compares multiple waveforms and computes energy mean and standard deviation for quality confirmation (optional add-on).
  • SDK available to develop custom automated test software and integrate with production test workflows.


Highlights
  • Single device replaces multiple instruments (defibrillation analyzer, external load box, oscilloscope), reducing setup complexity and inter-device interference.
  • Quick parameter setup via dedicated software with pass/fail criteria for adult/child modes per impedance value.
  • Automatic raw data storage: complete shock waveform data saved for a traceable test history.
  • R&R analysis capability supports endurance and consistency testing (separate purchase for R&R module).
  • SDK provided for flexible automation and to reduce repetitive operator tasks.


Energy Measurement Specifications
Maximum Energy: up to 600 J; Accuracy: ±1% of reading ±1 J up to 360 J; ±1% of reading ±1 J (typical) for 360–600 J. Voltage: up to ±3000 V; Accuracy: ±(1% of reading +1 V) for |450–3000 V|; ±(1% of reading +2 V) for -450 V – 450 V. Current: 1.2 – 100.0 A; Accuracy: ±(1% of reading +0.1 A). Load Resistance: 25, 50, 75, 100, 125, 150, 175, 200 Ω. Energy Accuracy: For 50 Ω: ±1% of reading ±0.1 J up to 360 J; ±1% of reading ±0.1 J (typical) for 360–600 J. For other resistances: ±2% of reading ±0.1 J up to 360 J; ±2% of reading ±0.1 J (typical) for 360–600 J. Pulse Trigger Level: 60 V. Pulse Width: 1.0 – 60.0 ms; Accuracy ±0.05 ms. Sample Rate: 250 kHz (4 μs sample). Maximum Average Power: 24 W (equivalent to 1 defibrillation pulse of 360 J every 15 seconds).

ECG Signal Specifications
Ventricular Fibrillation - Coarse: Vp-p = 3 mV. Ventricular Fibrillation - Fine: Vp-p = 0.5 mV. Ventricular Tachycardia (≈180 BPM): Vp-p = 3 mV. Ventricular Tachycardia Plus (≈234 BPM): Vp-p = 3 mV. Atrial Fibrillation: Vp-p = 1.2 mV. Asystole: Vp-p = 0.03 mV. Normal Sinus Rhythm (NSR) 20–360 BPM (1 BPM step): Vp-p 0.25 – 5.0 mV, step 0.5 mV. User-defined Pattern (max. 5 kHz sample rate): load up to 1000 seconds total of raw data files to device memory; Play Data supports direct playback of raw files from a computer with no file size limit. RCA Output Amplitude Range: 1:875. RCA Output Amplitude Accuracy: <7.5% Vpp, typical ±5% Vpp.

ECG Performance Waveform Parameters (selection)
Sine/Triangle/Square Frequency: 1–10 Hz; Amplitude: 0.25–5.0 mV. ECG Frequency: 0.33–6 Hz (step 1 Hz); P Amplitude 0–2 mV; R Amplitude 0–5 mV; T Amplitude 0–4.37 mV; PR Interval 0–200 ms; QRS Duration 5–200 ms; QT Interval 100–900 ms; P Duration 50–100 ms.

General Specifications
Operating Temperature: 0°C – 50°C (32°F – 122°F). Storage Temperature: -20°C – +60°C (-4°F – +140°F). Humidity: 10% – 90% non-condensing. Communications: USB Type-C; Operation Modes: Remote (PC Software via API and SDK). Power: DC 12 V power adaptor. Mechanical: Housing ABS plastic; Size (L x W x H): 24.0 x 24.0 x 6.0 cm; Weight: 1.6 kg.

Compliance Specifications
Safety Standards: CE: IEC/EN 61010-1:2010 + A1:2016; Pollution degree 2; 61010-2-030:2017. EMC Standards: CE EN61326-1; FCC: EMC P15B.

Package Contents (standard)
  • DFS400 x 1
  • DC12V power adaptor x 1
  • Open-ended AED cable (Banana Male, 0.5 m, Black) x 1
  • Open-ended AED cable (Banana Male, 0.5 m, Red) x 1
  • Compact splicing connector x 2
  • USB transfer cable: Type-A to Type-C (Male to Male, 1.8 m) x 1
  • RCA to BNC cable (73.8 cm) x 1


Optional Accessories & Add-ons
  • Optional paddle box set and docking base (various part numbers).
  • Optional accessories: additional DC12V adaptor, RCA-to-BNC cable, open-ended AED cables, compact splicing connector, USB transfer cable.
  • Optional software add-ons: Repeatability & Reproducibility Analysis module (optional purchase), Barcode Scanner License.
  • Optional calibration service and warranty extension options (3-year calibration coverage, warranty extension to 3 years).


Technical Specifications
  • Model: DFS400
  • Brand: WhaleTeq
  • Maximum Energy: up to 600 J; accuracy ±1% reading ±1 J (up to 360 J), typical ±1% (360–600 J).
  • Voltage Range: up to ±3000 V; Current Range: 1.2–100.0 A.
  • Built-in switchable loads: 25 / 50 / 75 / 100 / 125 / 150 / 175 / 200 Ω.
  • Energy accuracy (50 Ω): ±1% reading ±0.1 J (up to 360 J).
  • Sampling: 250 kHz (4 μs).
  • Pulse width: 1.0–60.0 ms; trigger level 60 V.
  • Max avg power: 24 W (360 J pulse every 15 s equivalent).
  • ECG outputs: multiple arrhythmia waveforms and user-defined waveform playback (up to 5 kHz sample for user-defined).
  • Communications: USB Type-C; SDK and API support for automation.
  • Power supply: DC12V adaptor.
  • Dimensions & Weight: 24.0 x 24.0 x 6.0 cm; 1.6 kg.
  • Safety & EMC: IEC/EN 61010-1, 61010-2-030; EN61326-1; FCC EMC P15B.