Control tester DFS360
signalfor external defibrillators

Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators
Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators
Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators - image - 2
Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators - image - 3
Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators - image - 4
Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators - image - 5
Control tester - DFS360 - WhaleTeq Co., Ltd - signal / for external defibrillators - image - 6
Add to favorites
Compare this product

Characteristics

Tested parameter
control, signal
Applications
for external defibrillators
Weight

0.7 kg
(1.5 lb)

Width

12.5 cm
(4.9 in)

Height

6 cm
(2.4 in)

Description

Overview
Designed for engineers and test laboratories at AED/defibrillator manufacturers, the DFS360 combines a defibrillation analyzer, external load simulation and oscilloscope functions in one compact tester. Dedicated software displays and automatically saves shock waveform, energy (J), parameters and characteristic points to create a searchable and traceable test history. The built-in 50 Ω impedance meets common regulatory and performance test requirements. The DFS360 supports Repeatability & Reproducibility (R&R) analysis and provides an SDK for automated test sequences and PC/API integration.

Functions
  • ECG Signal Output: outputs shockable and non-shockable rhythms for AED interpretation testing (VF coarse/fine, VT, AF, asystole, NSR).
  • Shock Waveform & Energy Measurement: captures and displays shock waveform, energy (J), parameters and characteristic points; sampling interval 4 μs; adjustable cursors for detailed analysis.
  • Basic Waveform Output: generates sine, square and triangle waveforms with configurable BPM, frequency and amplitude; adjustable ECG waveform voltage and timing parameters.
  • Built-in 50 Ω Impedance: simulates average human load without external accessories, suitable for standard performance verification.
  • Raw Data Playback: plays ECG databases and user-defined or clinically recorded waveforms for repeatable verification and development.
  • Simple Automated Testing: Auto Sequence function stores frequently used test items for automated execution.
  • Shock Waveform Analysis: R&R analysis compares multiple shock records and calculates mean and standard deviation of energy to quantify consistency.


Highlights
  • Single device integrates multiple test functions, reducing setup complexity and inter-device noise.
  • Dedicated software for fast parameter setup and automatic saving of test results to build a searchable history.
  • SDK available to develop custom automated test software and control the device via PC/API.


Package (standard)
  • DFS360 unit
  • Open-ended AED cable (Banana Male, 0.5 m, Black) ×1
  • Open-ended AED cable (Banana Male, 0.5 m, Red) ×1
  • Compact splicing connector ×2
  • USB transfer cable Type-A to Type-C (Male to Male, 1.8 m) ×1
  • RCA to BNC cable (73.8 cm) ×1


Technical specifications
  • Energy measurement: Maximum energy up to 600 J. Accuracy: ±1% of reading ±1 J for up to 360 J; ±1% of reading ±1 J (typ.) for 360–600 J. Voltage range up to ±3000 V (accuracy ±(1% of reading +1 V) for 450–3000 V and −450 to −3000 V; ±(1% of reading +2 V) for −450 V to 450 V). Current range 1.2–100.0 A (accuracy ±(1% of reading +0.1 A)). Load resistance 50 Ω. Energy accuracy at 50 Ω: ±1% of reading ±0.1 J up to 360 J; ±1% of reading ±0.1 J (typ.) for 360–600 J. Pulse trigger level 60 V. Pulse width 1.0–60.0 ms (accuracy ±0.05 ms). Sample rate 250 kHz (4 μs sample). Maximum average power 12 W (equivalent to one 360 J pulse every 30 s).
  • ECG signal: VF (coarse) Vpp = 3 mV; VF (fine) Vpp = 0.5 mV; VT (~180 BPM) Vpp = 3 mV; VT plus (~234 BPM) Vpp = 3 mV; AF Vpp = 1.2 mV; Asystole Vpp = 0.03 mV. NSR 20–360 BPM (1 BPM steps): Vpp 0.25–5.0 mV (step 0.5 mV). User-defined patterns: up to 5 kHz sample rate; load custom waveform capacity up to 1000 s total; direct playback from PC (no file size limit). RCA output amplitude range and accuracy: 1:880, ±5% Vpp.
  • ECG waveform parameters (selected): Sine/triangle/square frequency 1–10 Hz; amplitude 0.25–5.0 mV. ECG frequency 0.33–6 Hz. P amplitude 0–2 mV. R amplitude 0–5 mV. T amplitude 0–4.37 mV. PR interval 0–200 ms. QRS duration 5–200 ms. QT interval 100–900 ms. P duration 50–100 ms.
  • General: Operating temperature 0°C–50°C; storage −20°C–+60°C. Humidity 10%–90% non-condensing. Communications: USB Type-C. Operation modes: Remote via PC software using API/SDK. Power: USB 3.0 bus power. Mechanical: ABS housing; Size (L×W×H) 19.0 × 12.5 × 6.0 cm. Weight 665 g.
  • Compliance: Safety CE IEC/EN 61010-1:2010 + A1:2016; pollution degree 2; 61010-2-030:2017. EMC CE EN61326-1; FCC EMC P15B.
  • Optional/add-ons: R&R analysis software add-on, barcode scanner license and accessories (docking base, receiving plate, paddle box set, optional cables/transfer leads), calibration service and warranty extensions.