- Medical & Pharmaceutical industry >
- Pharmaceutical industry >
- Integrity tester
Integrity testers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
With the KHD 3000 wireless glove testing system, Syntegon offers the first test method in the world that can be completely integrated into the production line in accordance with ISO specifications for RABS and isolators. The test parameters can be adapted ...
glove integrity testerGIT-WLAN02
Analysis duration: 3 min - 6 min
Weight: 3 kg
... methodology; aligns with FDA guidance for routine physical
integrity testing of aseptically processed sterile products.
Applications
Intended for glove/sleeve
integrity testing on isolators and ...
Tailin
Analysis duration: max 6.0 min
Weight: max 3.0 kg
... Product Introduction
The GIT-WLAN03 is a portable glove
integrity
tester designed for leak testing gloves mounted on isolators or RABS. It uses wireless communication, RFID identification and intelligent ...
Tailin
Analysis duration: 5 min - 8 min
Weight: 12.5 kg
Width: 245 mm
... for in-situ testing of glove integrity on isolators and RABS. The device uses a pressure-decay method in accordance with ISO14644-7 to detect leaks in glove, sleeve and port assemblies, supporting routine and periodic integrity ...
Tailin
... <b>Overview</b><br>The glove tester enables rapid and reliable detection of perforations using a traceable, reproducible method that complies with current regulations, in particular Annex 1 of GMP. The system can be ...
... AGLTS 2 is the brand new fully automatic GMP compliant glove integrity testing system for isolators and RABS in the pharmaceutical industry, developed referring to the Positive Pressure Decay Method which follows the ...
... BPT has been conceived as a specific instrument to perform the filter integrity test, fully compliant to GMP normatives. It is an extremely versatile device, which is connectable to any filter to be tested (synthesis module, dispenser, ...
Weight: 8 kg
Width: 20 cm
Height: 21.5 cm
... accordance with YY/T 0698.5-2009 (Section 5). It determines the combined seal and coil joint strength and evaluates seal integrity before and after sterilization to verify compliance with required strength criteria and regulatory test ...
... Product overview
- Desktop medical insulation detector designed to inspect insulation integrity of medical devices and sterile packaging for quality control and production processes.
Applications
- Used
... Overview
The SEEG 100 is an EEG performance
tester engineered for regulatory verification, R&D and production-line validation. It supports IEC 60601-2-26:2012, GB 9706.226-2021 and related standards and delivers sub-microvolt ...
... rejection ratio (CMRR) test verifies whether the device under test (DUT) suppresses common-mode interference to preserve signal integrity and diagnostic accuracy. CMRR 3.0E uses double-layer circuit shielding and a dedicated external ...
... Pa. On the face of the tester there is an ergonomic, antibacterial handle and a quick coupler for a compressed air supply by hose either directly from the output of the isolator or an external source. This tester ...
The standards of quality for flexible packaging continue to be a challenge for manufacturers. PTI’s VeriPac FLEX systems have been established globally as a technology proven to reduce production waste and cost while improving package quality assurance ...
... Integrity test of Planova BioEX is conducted to ensure the integrity of the filter when used in filtration process. The following qualities allow for a simple user integrity test required to be conducted ...
Asahi Kasei Medical
... control. In the ever-changing world of production, real-time and permanent monitoring is crucial to protect your products’ integrity. The SUTO S601 monitors contaminants, giving businesses piece of mind that its products and customers ...
... The FZ-GTS 4.0 with the latest software technology offers an extremely flexible and fully integrable solution for glove testing as part of glove management. Characteristics: Server-Client-Solution Active Directory OPC UA/ SCADA Multiple testing ...
... developing smart products that bolster quality, reduce risk and provide a second to none customer experience, the AccuFlux® integrity test system is engineered to combine the highest levels of instrument accuracy, robustness, and ease ...
... pressure is measured over a certain time. This variation is an accurate reflection of the level of integrity of the container. This deterministic integrity test method is recommended by the FDA as a replacement for traditional ...
ASC Instrument
glove integrity testing systemGST® - Gloves Sleeves Tester
... calibrated; simple verification of instrument performance with a filter set Continuous monitoring of sample flow assures integrity of measured data Your benefits Straight forward instrument set-up and qualification allows rapid ...
... A filter Integrity Test System is available. In-situ integrity testing of aseptic system filters can be performed on the air and product filters installed on the machine. The test circuits are set up automatically for ...
... The BC Biomedical Model SA-2600 -AUS is a fully automated microprocessor-based Electrical Safety Analyzer with built in Patient Simulator and Bluetooth technology. The SA-2600-AUS has fully customizable autosequence allowing for a full ...
BC Group
... The Mobile Glove Testing System GTS for automatic integrity testing of the gloves is equipped with 6 test covers. Each test cover has an RFID (Radio Frequency Identification) reading head which is responsible for the ...
Metall + Plastic
... determine the concentration of each individual compound: CO ppm V GfX infrared gas analyzer CO2 ppm v GfX infrared gas analyzer O2 Vol% Pm paramagnetic gas analyzer (with atmospheric pressure ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.