- Secondary care >
- Orthopedic surgery >
- Cementless femoral stem >
- Amplitude
Amplitude cementless femoral stems
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Femoral stem length: 171, 91 mm
... available. Extra-medullary part evolves with stem’s size: Lateralization and CCD angle are larger on larger sizes. High Offset option collarless — 8 sizes available. Collar starting in the internal axis of the stem: ...
Amplitude Surgical
Femoral stem length: 98, 134 mm
CCD angle: 137, 129 °
... Standard stem corresponds to a modular ACOR® stem with A/R neck and regular anteversion/retroversion values. The joint centre of the Lateralised stem corresponds to a modular ACOR® stem ...
Amplitude Surgical
Femoral stem length: 134, 98 mm
CCD angle: 137, 140, 129 °
... connection. Threaded hole at bottom of cavity for extraction tool. Impaction point at top of stem is offset to ensure impaction is in line with shaft axis. Stem–neck combination: titanium–titanium. Range ...
Amplitude Surgical
CCD angle: 137 °
... Oval impaction hole on top of stem Threaded hole used for extraction Femur stem option within a product line based on the same concept: - INTEGRALE®: fully coated, straight femoral ...
Amplitude Surgical
Femoral stem length: 87, 116 mm
CCD angle: 135, 127 °
... divided into 3 families of 3 stems Collar has the same antero-posterior width as the stem : Good visibilty of intra-medullary part of impaction Bone conserving in caseof extraction Collar dimension ...
Amplitude Surgical
Femoral stem length: 194, 164 mm
CCD angle: 135 °
... INTEGRALE® primary femoral stem in proximal segment: -Neck was lengthened to preserve height of femoral head centre. Oval impaction hole on top of stem. Threaded ...
Amplitude Surgical
Femoral stem length: 200, 250 mm
... Impaction point at top of stem is offset to ensure impaction is in line with shaft axis. Locking threaded pin Ø 4.7 mm. Threaded area below head: Ø 6.5 mm cortical thread. Rounded screw head. Material: titanium. Femur ...
Amplitude Surgical
Femoral stem length: 250, 200 mm
... revision and reconstruction: -GENERIC® Revision: cemented straight femoral stem. -INTEGRALE® Revision: cementless straight femoral stem. -OPTIMAL: ...
Amplitude Surgical
Femoral stem length: 250, 400 mm
Product line consists of 4 metaphyseal sizes, 6 nail diameters and 4 lengths. Partial HAP coating. Material: titanium. Impaction limit corresponds to HAP boundary Ovoid shape and grooves increase the contact area for secondary fixation. Nail ...
Amplitude Surgical
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining