- Secondary care >
- Orthopedic surgery >
- Cervical arthrodesis plates
Cervical arthrodesis plates
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... Quintex® Hybrid All-In-One Anterior Cervical Plating System The Quintex® cervical plating system offers four distinct implant combinations. Constructs may be "dynaminized" or "hybridized" to accommodate patient-specific clinical and anatomical considerations. ...
... ABC2 Anterior Cervical Plating System ABC's dynamic load sharing plate design revolutionized cervical spine treatment. ABC facilitates earlier and more substantial graft incorporation, because the ABC screw can slide in the plate and adapt to graft ...
... The Pyrenees Constrained Cervical Plate System offers a low-profile design. Featuring SMARTLock Technology, the system does not require an additional locking mechanism, as each screw head forms an autogenic lock to the plate upon insertion. Features ...
Anterior cervical discectomy and fusion (ACDF) is a type of cervical spine surgery from the front (anterior) of the neck (cervical) that often successfully addresses spinal symptoms. ACDF surgery is a very common procedure relative to overall spine surgeries ...
Number of holes: 4, 8, 6 unit
... Indication: -Trauma,degenerative diseases, tumor, spinal canal stenosis and instability & spondylolisthesis caused by fusion failure. -Non limiting system;large viewport; visible endplate; self-taooing screw; low profile plate with locking device; screw ...
Length: 25 mm - 65 mm
Number of holes: 6, 8, 4 unit
SOFEMED efficient, and mechanical tested systems for spine surgery according to European medical devices testing center.
CanACE is designed to stabilize the cervical spine during surgical procedures. The system features a one-step locking mechanism that enhances stability, reducing the need for contouring. The pre-lordosis plates are designed to reduce the need for contouring, ...
Thickness: 2 mm
The CanACP is a cutting-edge anterior cervical plate used in spinal surgeries to provide support and stability to the cervical spine. One of its most notable features is its low-profile design, which is only 2mm thick. This thin profile reduces the amount ...
... Category: Cervical Plate Color: Black, Gray - Product Type: Cervical Plate - Available Colors: Black, Gray Technical Specifications / Features: - Category: Cervical Plate - Color options: Black, Gray ...
Length: 14 mm - 101 mm
... • Degenerative dise disease (Defined as discogenic pain with degeneration of the dise confirmed by history and radiographie) • Trauma (Including fracture) • Tumours • Post-traumatic kyhposis or lordosis • Revision operations neccessitated by failed ...
Length: 22, 30, 32, 50, 71 mm
Thickness: 1.8 mm
Number of holes: 4, 6, 8 unit
... Anterior Cervical Plate-II System - Low profile design, plate thickness is 1.8mm - Unique observing window on the plate, helps checking the implant status - Screws on the coronal plane can be adjusted within 12°, and within 10° on the sagittal plane Indications: ...
... • Provide high strength with low thickness • Provide effective and simple use • Low profile (totally 2 mm) • Flexible blocking system securely to the screw ...
... It can be used for anterior fixation of cervical spine in operations such as cervical degenerative disease, cervical trauma, dislocation, and removal of cervical tumor focus.
Product Portfolio
※Screw
• Large angle design ...
... Titanium cervical spinal plate Use titanium cortical screws, 3.5 mm Ø ...
... The system is indicated for use in cervical fusion procedures with or without tasarimmed cervical cage systems in skeletally mature patients with degenerative disc disease (DDD) from the C2 to C7 disc. Features: Anatomical shape Wide range of sizes Simple ...
Length: 85, 20 mm
Number of holes: 4, 8 unit
Anterior cervical plate has been used for the operative treatment of disc degeneration and trauma for several years. With its extensive application, this kind of plate is required to be on a higher level of lower profile and narrower width, in order to ...
... The FlexWing Anterior Cervical Plate System is intended for anterior vertebral screw fixation of the cervical spine at levels C2-T1. The System is indicated for temporary stabilization of the anterior spine during the development of cervical spine ...
Number of holes: 6 unit
... Can be used for one or more segments Quite thin plate No height on the plate ...
Length: 20, 100 mm
Thickness: 2 mm
Number of holes: 4, 6, 8, 10 unit
... Prodorth Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery and it offers a wide range of plates and screw sizes. Low profile pre-bended plates Single driver to place screws and secure the locking mechanism Different ...
Length: 17, 90 mm
Number of holes: 10, 4, 8 unit
... Five different length options with two different diameters High degree of titanium alloy screw angulation Streamlined instrumentation ...
... 1.Degenerative disc disease 2.Trauma 3.Tumors 4.Deformity (defined as kyphosis, lordosis, or scoliosis) 5.Pseudarthrosis 6.Failed previous fusions A variety of implants and instrument systems are available to meet surgeons' needs and personal ...
Double Medical Technology
Length: 22, 72 mm
... The Origin anterior plate serves to stabilize the cervical spine. Its locking system is particularly impressive, enabling two placed screws to be locked with one twist. -Pre-curved plate with locking system -Fixation holes for anchoring screws in ...
The Mecta-C family of Cervical Interbody Fusion Cages and Anterior Plates represent a complete system to fuse and mechanically support the cervical spine in case of degenerative disease, trauma, tumors and deformity. The Mecta-C Cage System consists of ...
... anterior cervical plate that requires only one step for inserting and locking screws into place. The ASSURE®-T translational plate adopts these core benefits while allowing for graft settling at every level to help promote fusion. Features and Benefits One-Step ...
... Streamlined instrumentation accommodates the needs of the patients and surgeons. CAM locking mechanism ensures locking of screws for optimal angles Audible, tactile and visual confirmations of locking mechanism provide confidence in preventing screw ...
Life Spine
... Aspect® Anterior Cervical Plate System The Aspect® System is a simple, yet versatile anterior cervical plate system designed to meet the varying clinical needs of surgeons performing anterior cervical discectomy and fusion (ACDF) procedures. The system ...
Length: 23, 25, 27, 19, 21 mm
Thickness: 1.8 mm
Number of holes: 4, 6 unit
... Thickness: 1.8mm Material: Ti-6Al-4V Bone: Cervical Part: Anterior Series: Anterior Cervical Plate System Screws: 3.5mm/4.0mm Variable Angle Locking Screw Instrument: Anterior Cervical Plate Instrument Set Description Anterior Cervical Plate ...
Length: 105, 10 mm
Thickness: 1.9 mm
The Ambassador® Anterior Cervical Plate system is a versatile system of implants and instruments with a variety of sizes to provide optimal anatomic compatibility. The integrated cam-locking mechanism is designed to prevent screw backout. Ambassador features ...
ChoiceSpine
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group