Length: 22, 72 mm
The Origin anterior plate serves to stabilize the cervical spine. Its locking system is particularly impressive, enabling two placed screws to be locked with one twist. -Pre-curved plate ...
Length: 21, 80 mm
Number of holes: 8, 4 unit
Anterior Cervical Locking Fixation System (VI) Application: For anterior cervical internal fixation
... - Comprehensive plating System - Two plates and three screw styles offer distinct implant combinations - One intuitive instrument set - Thin 2 mm plate design - Large graft window - Integrated ...
... .g. no tapping, self-locking) - Faster implant placement - Excellent proven clinical outcome Features - Self-locking screws - Oversized revision screws - Plate marking for easier ...
Length: 39 mm
- Compression technology - Variable angle locking technology - Anatomical and special surgical implant
Number of holes: 4 unit
Anterior Ankle Fusion Plate Product Introduction 1.Anatomic design is good for reduction, and no need to pre-bend the plate duringsurgery to avoid effect on the plate strength when ...
Waston medical
Number of holes: 5, 6 unit
Metatarsophalangeal Joint Fusion Plate I Product Introduction 1.Anatomic design, 9° dorsal flexure, and 11°extorsion, to avoid effect on the plate strength while it is bendedduring surgery. 2.Plate ...
Waston medical
Number of holes: 4 unit
Metatarsophalangeal Joint Fusion Plate II Product Introduction 1.Anatomic design, 9° dorsal flexure, and 11°extorsion, to avoid effect on the plate strength while it is bendedduring surgery. 2.Plate ...
Waston medical
Anterior cervical plate is a semi rigid fixation for anterior interbody fixation of the cervical spine characterized by : Low profile plate. A curved profile to adapt anterior surface of the vertebral ...
Thickness: 1.2 mm
• The plates are bended according to the bone’s natural shapes.
Thickness: 1.5 mm
• The plates are bended according to the bone’s natural shapes.
Thickness: 1.8 mm
• The plates are bended according to the bone’s natural shapes.
Thickness: 5 mm
Number of holes: 6, 7 unit
ARIX CARPAL FUSION PLATE provides a specially designed solution for carpal bone fracture and management. Product Features • Fixing four-corner bones of carpal • Ø2.5mm Srews(locking/non-locking) Easy ...
... • The plate and the screw are fixed to hold the adjusted shape of the distal tibia after the osteotomy • Reduced thickness for less irritation • The Anterior Ankle Fusion Plate is indicated ...
... Product Features • Patented locking system for preventing screw pullout • Low profile • No extra locking • Easy removal of screws • Dual thread self-drilling and self-tapping screws Patented ...
Length: 53, 17 mm
Thickness: 1.2 mm
Number of holes: 4, 6, 8, 12, 16 unit
The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon the anatomical fixation required. Features It ...
Number of holes: 20 unit
Elbow ( Arthrodesis ) Plate Ø 3.5 - Ø 4.0 mm screw
Number of holes: 8 unit
Hand Carpus ( Arthrodesis ) Plate Ø 3,5 - Ø 4.0 mm screw
Length: 118, 102 mm
Thickness: 3.5 mm
345.1330340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Short,Left 345.2330340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Short,Right 345.1330440.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Anterior Ankle Fusion VA-LCP(AA-TT),Long,Left 345.2330440.15 ...
Health-Joy Medical
Length: 102, 118 mm
Thickness: 3.5 mm
345.1200340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion VA-LCP(PA-TTC),Short Left 345.2200340.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion VA-LCP(PA-TTC),Short Right 345.1200440.15 - Ø3.5/Ø4.5/Ø5.5//Ø6.5 Posterior Ankle Fusion ...
Health-Joy Medical
Length: 42, 47, 61, 72 mm
... First MTP Fusion VA-LOC Plate 365.1110042.15 - ¢2.7/¢3.5 First MTP Fusion VA-LOC Plate 0°,42mm,L 365.2110042.15 - ¢2.7/¢3.5 First MTP Fusion VA-LOC Plate 0°,42mm,R 365.1110542.15 ...
Health-Joy Medical
Hole diameter: 3.5 mm
Number of holes: 8 unit
Screws Used Ø3.5 Cortical Screw & Ø3.5 Locked Screw
Arthrodesis plate Shoulder arthrodesis Elbow arthrodesis
Length: 49, 192 mm
... the system offers 6 types of plates: -lateralTT-Tibiotalar andTTC-Tibiotalocalcaneal plates -anterolateral TT plates - posterior TT and TTC plates -anterior minimally ...
ChM
ACJ plate is intended for stabilization of the acromioclavicular joint in fresh injuries that occurred 7 up to 10 days before. The plate may be used as an alternative, in particular, for tension band ...
ChM
Number of holes: 6, 12 unit
... Concave profile • facilitated plate positioning • minimal bone removal • no intraoperative tilting of the plate Chamfered plate borders • minimized soft-tissue irritation Double ...
ChM
Number of holes: 6 unit
Can be used for one or more segments Quite thin plate No height on the plate
Length: 20, 100 mm
Thickness: 2 mm
Number of holes: 8, 10, 4, 6 unit
... Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery and it offers a wide range of plates and screw sizes. Low profile (2,0 mm) pre-bended plates Single ...
The system is indicated for use in cervical fusion procedures with or without tasarimmed cervical cage systems in skeletally mature patients with degenerative disc disease (DDD) from the C2 to C7 disc. Features: Anatomical shape Wide ...
Hole diameter: 2.7 mm
Number of holes: 4, 14 unit
... Astrolabe’s Midfoot 2,7 is indicated for MP Joint 1 Arthrodesis and Revisions, MP Joint 1 Iliac Crest Arthrodesis, Metatarsal Arthrodesis and Lisfranc Arthrodesis, Interposition ...
Astrolabe
Hole diameter: 3.5 mm
The Astrolabe’s Plantar plate is indicated for plantar Lapidus Arthrodesis as an evolved version of hallux valgus correction at certain angular degrees in order to prevent progression of arthrosis in ...
Astrolabe
... fixation and is indicated for Keller-Brandes Revisions, MTP 1 lengthening arthrodesis, Revision after MTP 1 prosthesis and MT 1 lengthening osteotomy. This anatomically shaped plate allows facilitated ...
Astrolabe
Length: 20, 100 mm
Thickness: 2 mm
Number of holes: 4, 6, 8, 10 unit
Prodorth Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery and it offers a wide range of plates and screw sizes. Low profile pre-bended plates Single ...
Length: 28, 35, 45 mm
Thickness: 2.7 mm
Number of holes: 5, 6 unit
FOREFOOT PLATING SYSTEM 2.7 4001080 5 - holes 28 mm, small size 4001081 6 - holes 35 mm, 10° valgus angle, medium size 4001082 6 - holes 45 mm, 10° valgus angle, large size
AGOMED Medizin-Technik
... ADVANTAGES COMPARED TO NAILING SYSTEMS • PRESERVATION OF THE PLANTAR SKIN • NO RISK TO THE PLANTAR NERVES • LOCKING TECHNOLOGY ALLOWS A RELIABLE GRIP IN THE CALCANEUS, THE TALUS AND THE TIBIA • APPLICATION ...
AGOMED Medizin-Technik
Length: 38, 98 mm
Number of holes: 4, 14 unit
• Arthrodesis of first MPJ • Metatarsal arthrodesis • Pseudarthrosis of Metatarsals • Revision arthrodesis of the MPJ • Iliac crest interposition arthrodesis of first ...
AGOMED Medizin-Technik
Resection and stabilization of the elbow with a titanium plate at the humerus and the proximal portion of the radius. Immobilization is inevitable in this clinical case.
Length: 23, 25, 27, 19, 21 mm
Thickness: 1.8 mm
Number of holes: 4, 6 unit
... Anterior Cervical Plate I, 4 Holes, 19mm Anterior Cervical Plate I, 4 Holes, 21mm Anterior Cervical Plate I, 4 Holes, 23mm Anterior Cervical Plate I, 4 Holes, 25mm Anterior ...
Length: 85, 20 mm
Number of holes: 4, 8 unit
... peripheral tissues, we must ensure the plate to be stabilized firmly, without the screw migration in the long term of activity. Therefore, an antimigration mechanism must be added into cervical plate ...
• Provide high strength with low thickness • Provide effective and simple use • Low profile (totally 2 mm) • Flexible blocking system securely to the screw
• Straight Plate ,self-locking screws, nuts and washers create a rigid fixation
Number of holes: 8, 18 unit
... Benefits Sternal Plates Titanium straight locking plates for sternal and rib-to-rib fixation. Titanium star-shaped and H-shaped plates for fixation of the manubrium. Release ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining