{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
cemented femoral stem
cemented femoral stem
Trilliance®

Trilliance® Hip Stem System Triple tapered. Polished. The Trilliance® hip stem is designed for cemented implantation. The design features are based on the third generation of straight ...

cemented femoral stem
cemented femoral stem
2145-0125

Polished Femoral Stem: Config Drawing No: SW-00006-15 Material = CoCrMo (casted) Polished Femoral Stem LONG: Config Drawing No: SW-00006-28 Material = CoCrMo (casted)

cemented femoral stem
cemented femoral stem

To be cemented stem FILLER to be cemented ( Primary stem) From 8 to 20 Mirror polished stem Conus: 5°42'30'' (12/14) Stainless steel forged with strong ...

cemented femoral stem
cemented femoral stem
KORUS

... MODELS with CCD 135° and 125° angles, CEMENTED KORUS, also available with a DISTAL CENTRALIZER and MODULAR KORUS, provided with 14 interchangeable necks.- Available with or without distal centralizer. Straight cemented ...

cemented femoral stem
cemented femoral stem
Self-locking

– Self-locking grooved lateralized and medialized stem – Self-locking smooth stem Materials High nitrogen content stainless, to ISO 5832/9. Thanks to the high nitrogen content and the final post-casting ...

cemented femoral stem
cemented femoral stem
LOUXOR

Characteristics Straight stem with rectangular cross-section HAP coating except at the distal end Cementless Without plate

See the other products
Aston Medical - Science et Médecine
cemented femoral stem
cemented femoral stem
SEM III

Characteristics Straight stem with ovoid section Cemented stainless steel Available in long version – 200mm and 250mm

See the other products
Aston Medical - Science et Médecine
cemented femoral stem
cemented femoral stem
SEM IV

Characteristics Straight stem Charnley Kerboull like Cemented 5 collar length families 3 sizes available in 200mm long version

See the other products
Aston Medical - Science et Médecine
cemented femoral stem
cemented femoral stem
SGV®

cemented femoral stem
cemented femoral stem
KAREY-C®

Stem Karey cemented The KAREY-C ® system for total hip arthroplasty has been designed to provide an optimal combination of strength and minimizing geometry setting offering a respectful anatomy in which ...

See the other products
Surgival
cemented femoral stem
cemented femoral stem
SELF-LOCKING STAINLESS STEEL

Self-locking stainless steel Stem nitrogen Self-locking rod system provides a simple, practical and reliable solution endorsed for years of clinical experience, has a simple rectangular geometry that allows anti-rotational ...

See the other products
Surgival
cemented femoral stem
cemented femoral stem
SELF-LOCKING TITANIUM

Stem self-locking traditional femoral stem / Cemented / Titanium

See the other products
Surgival
cemented femoral stem
cemented femoral stem

... caused by the friction between stem neck and UHMWPE component Standard Offsets Reduced proportionate Neck Geometry to increase Range of motion Design Cemented stem BC is made of Co-Cr- ...

cemented femoral stem
cemented femoral stem
LINK® Standard C

LINK® Standard C Cem Cemented standard stem The prosthesis stems of the Standard C system are made of alloy steel FeCrNiMnMoNbN (M30NW) and have a highly polished surface. The prosthesis ...

See the other products
Waldemar Link
cemented femoral stem
cemented femoral stem
LINK® Standard M

... insertion of the stem into the medullary canal. The stem has a groove on the anterior and posterior side to facilitate insertion of the stem and enable the exit of excess cement. Cemented ...

See the other products
Waldemar Link
revision femoral stem / cemented
revision femoral stem
LINK® SPII®

... SPII® Long Prosthesis Stem, anatomical 12/14 taper Right and left design (anatomical design) Stem lengths 200–350 mm Five stem widths 126° and 135° CCD angles obtainable SPII® Long Prosthesis ...

See the other products
Waldemar Link
minimally invasive femoral stem / cemented
minimally invasive femoral stem
FRIENDLY

Friendly Short The Friendly Shortstem is a straight, short cemented stem for total hip replacement. The stem is made of FeCrNiMnMoNbN alloy to be used with a IV generation cementing ...

cemented femoral stem
cemented femoral stem
LOGICA series

... cementless stems), allows for an intra-surgical choice of stems. The LOGICA stem has a medially rounded section with laterally prominent angles to adapt the stem profile ...

revision femoral stem / cemented
revision femoral stem
AMIStem-C

9 STANDARD sizes, from 0 to 8, with 135° neck-shaft angle 9 LATERALIZED sizes, from 0 to 8, with 127° neck-shaft angle

revision femoral stem / cemented
revision femoral stem
QUADRA-C

• 8 STANDARD sizes with 135° neck-shaft angle and 7 LATERALISED sizes with 127° neck-shaft angle.

cemented femoral stem
cemented femoral stem
CINÉOS® C

10 sizes. Stem is 0.7 mm smaller than the rasp. Homogenous and uniform cement coating. Rounded angles minimising stress on the cement. Mini-ring for compressing cement and indicating ideal insertion depth in the femur. Material: ...

cemented femoral stem
cemented femoral stem
NAOS® C

8 sizes. The Naos® C is 0.7 mm smaller than the rasp. Homogenous and uniform cement coating. Rounded angles minimising stress on the cement. Mini-ring for compressing cement and indicating ideal insertion depth in ...

minimally invasive femoral stem / cemented
minimally invasive femoral stem
NAOS® CXHO

8 sizes. The Naos® C XHO is 0.7 mm smaller than the rasp. Homogenous and uniform cement coating. Rounded angles minimising stress on the cement. Mini-ring for compressing cement and indicating ideal insertion depth ...

cemented femoral stem
cemented femoral stem
BEZNOSKA TRIO

... IMPLANTOptional use of cemented or cementless implantation, depending on type of neckCemented stem in combination with a centralizerCementless variant with optional choice between fixed stem ...

cemented femoral stem
cemented femoral stem
Poldi

... reliability.Relatively small stem Suitable also for mini-invasive operations.CD angle 140°Innovated instruments – 8 rasps (for each size of stem) with quick-grip handleFor optimal results we recommend ...

cemented femoral stem
cemented femoral stem
SAGITTA EVL

... -locking femoral stem for implantation with and without cement. Today, the Sagitta EVL hip system offers new design features and is available in four versions : CEMENTED, CEMENTLESS, ...

cemented femoral stem
cemented femoral stem
TSF®

... Calcar Replacement Stem is a cemented femoral stem manufactured from stainless steel with a high nitrogen content (M30NW). Its entire surface is highly polished. Indications ...

cemented femoral stem
cemented femoral stem
C-STEM™ AMT

... from the stem to the proximal femur is achieved through the addition of this third taper. The effects of stress shielding are also minimized. These features coupled with the Summit platform;s biomechanic ...

cemented femoral stem
cemented femoral stem
Foundation® series

... needs, all with one standard set of instrumentation. The system offers cemented stems with the 450 and 460 series, porous stems with the 470 and 480 series and a press-fit 440 series ...

revision femoral stem / cemented
revision femoral stem
sirius

The Sirius femoral stem is a short cemented stem with a proven taper-slip philosophy for use in both primary and revision hip arthroplasty. 1,2 This stem ...

cemented femoral stem
cemented femoral stem
ACOR®

HIP - FEMORAL STEMS - PRIMARY Primary Anatomical Femoral Stems The ACOR® Modular stem is available in cemented and cementless versions. Neck ...

See the other products
Amplitude Surgical
cemented femoral stem
cemented femoral stem
LATITUD™

Cemented stems in hip replacement surgery have been in use since the pioneering years of Sir John Charnley. The polished dual-tapered LATITUD stem is based on the highly successful loaded ...

cemented femoral stem
cemented femoral stem
PROFEMUR® Z

With modular necks, the stem is streamlined relative to traditional fixed neck implants. PROFEMUR™ Z implants simplify stem insertion and minimize soft tissue stretching. The streamlined geometry also ...

See the other products
Shanghai Microport Orthopedics
cemented femoral stem
cemented femoral stem
THIRA

... range of femoral stems is adapted to first intention hip operations, following coxarthrosis, fracture of the neck of the femur (as an intermediate hip prosthesis) or finally in case of ...

cemented femoral stem
cemented femoral stem
EuroMAXX

- Greater freedom of choice by the doctor; - Cutting-edge raw material; - Rectangular Profile, wedge-shaped in longitudinal direction, which allows an homogeneous charge distribution; - Off Set options from 36.5 to 44mm; - PMMA distal ...

See the other products
BAUMER
cemented femoral stem
cemented femoral stem

Volumed Modular Straight Stem (Cemented) Type Stainless Steel 7,5 mm - 12/14 10 mm - 12/14 11 mm - 12/14 12,5 mm - 12/14 15 mm - 12/14

cemented femoral stem
cemented femoral stem
BC1

Smooth prosthesis edges avoid stress concentration and cutting the bone cement; Biplanar taper without collar converts longitudinal shear force to lateral compression load; Highly polished surface reduces the shear force between the prosthesis ...

cemented femoral stem
cemented femoral stem
PLM

PLM: Right lateralized femoral stem with or without cement PLM Stem emerged from the auto-blocker Müller concept. Benefits from 20 years of clinical long-term effects.