- Secondary care >
- Orthopedic surgery >
- Left femoral stem
Left femoral stems
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Femoral stem length: 7.5, 13.5 mm
Acetabular cup diameter: 22 mm - 28 mm
Femoral head diameter: 42 mm - 62 mm
Femoral Stem Dual Coated Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Bipolar Head Acetabular Screw Acetabular Liner (10°) Acetabular ...
Femoral stem length: 55, 25 mm
Femoral stem offset: 17, 9 mm
Acetabular cup diameter: 42 mm - 62 mm
Calcar Replacement Stem Dual Coated (Cementless) SIZE (mm) 25/9 25/11 25/13 35/9 35/11 35/13 35/15 35/16 35/17 45/9 45/11 45/13 55/9 55/11 55/13
... rectangular form of the CLP® hip stem assures rotational stability by providing a mechanical interlock with the proximal femoral cortical bone. Unique Contour The unique contour that conforms to the ...
CCD angle: 127 °
... philosophy of anatomical stems was introduced into the market during the 1980's with the aim to obtain the best press-fit in the metaphyseal femur using a design following the natural geometry of the ...
Femoral stem length: 171, 91 mm
... available. Extra-medullary part evolves with stem’s size: Lateralization and CCD angle are larger on larger sizes. High Offset option collarless — 8 sizes available. Collar starting in the internal axis of the stem: ...
Amplitude Surgical
Femoral stem length: 130, 150, 170 mm
Femoral stem offset: 35, 40, 37, 49, 46 mm
CCD angle: 117, 135, 126 °
... anatomical shape of the femur Successfully used for 40 years Proven by a wealth of clinical data. Minimal occurrence of periprosthetic fractures Minimally invasive implantation Neutralizes torsional forces: The ...
Waldemar Link
... old fracture of the femoral neck, pain from destruction of the femoral head or acetabulum, resulting in impairment of joint function; 2. Patients with avascular necrosis of the femoral ...
Wuhan Yijiabao Biological Materials
... biologic fixation and increasing rotational stability. Stability PROVEN METAPHYSEAL INTEGRATION The proximal design of the stem in the shape of a three-dimensional taper leads to partial filling of the metaphysis ...
Femoral stem length: 250, 180, 325 mm
CCD angle: 133 °
The SAGITTA EVL R stem is an anatomical femoral implant for revision surgery designed for prosthesis revision with or without a femoral flap. The stem is destined to ...
... of the key advantages of the SKM Stem is that it ideally facilitates the Minimally Invasive operation technique. With its unique anatomical design and the wide range of available left and right sizes, ...
The ESOP femoral stem was developed in 1991 in order to match the shape of the femoral stem to the shape of the patient’s bone. This stem has 2 components: – ...
CCD angle: 135, 125 °
... centralizer; Refined distal end to facilitate stem insertion and reduce stresses acting on the cement mantle; Diaphyseal wedge shape: guarantees excellent rotational stability and facilitates the insertion of the stem, ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining