- Secondary care >
- Orthopedic surgery >
- Primary hip prosthesis
Primary hip prostheses
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... State of Arthroplasty The Metha Short Hip Stem prosthesis represents a new generation of implants for hip endoprosthesis. It combines two advantages: minimal stem size and a circumferential coating. ...
Aesculap®
... distally slim implant design and the standardized implantation technique allow the implant to be used in different femoral anatomies with or without bone cement – with standard or high offset – suitable for all less invasive ...
Aesculap®
... system – for all less invasive surgical hip approaches Excia® straight stems are designed for implant longevity with or without bone cement – with standard or high offset – suitable for all less invasive surgical hip ...
Aesculap®
Femoral stem offset: 36, 54 mm
... The ACTIS™ Hip Stem’s patented1 design offers proven implant stability2, with over 400,000 in clinical use3. The ACTIS Hip Stem is powered by enabling technologies KINCISE™ Surgical Automated System and ...
Depuy Synthes
... range of motion than circular neck designs,* which may reduce the potential risk of dislocation. The ANTHOLOGY AFIT Primary Hip System features a reduced distal cross-section as an option for patients with a narrow ...
CCD angle: 135 °
... approaches to total hip arthroplasty. The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, which facilitates the implantation ...
Enovis Surgical
... Biological Hip Prosthesis System The product design is based on human engineering mechanics, human biology and long-term clinical pathology research. It is made of materials recognized in the world's medical field, which ...
... ALPINE® HIP STEMS The Alpine® Hip System is designed with optimal refinements to the best clinically proven technologies in the market. The stems are offered in cemented and cementless options with common instrumentation ...
... Overview
The total
hip
prosthesis is designed for patients requiring
hip joint replacement due to arthritis, fracture, or other conditions. It provides improved mobility and pain relief.
Features
- Durable
... CANWELL Primary Cementless Femoral Stem Artificial Hip Prosthetics Joint Replacement Total Hip Replacement CE - Category: Hip & Knee - Brand: Canwell Medical - Type: ...
Femoral stem length: 7.5, 13.5 mm
... Femoral Stem Dual Coated (Cementless) SIZE (mm) 7.5 9 10 11 12 13.5 ...
Zimed Medical
Femoral stem length: 7, 12 mm
... Femoral Stem (Cemented) Hip Replacement SIZE (mm) 7 8 9 10 11 12 ...
Zimed Medical
Femoral stem length: 9, 55 mm
... Calcar Replacement Sandblasting Stem (Cemented) Hip Replacement ...
Zimed Medical
... Titanium total hip prosthesis Medium necks BM0 BM1 BM2 BM3 BM4 BM5 Long necks BM0 BM1 BM2 BM3 BM4 BM5 ...
... Custom-made stems from scanner sections Hip prostheses adapted to people of small stature ...
... Hip prosthesis for bone tumor Hip arthroplasty in Pediatric Patient with Cerebral Palsy Pediatric custom made total hip prosthesis ...
Femoral stem length: 125, 150 mm
Femoral stem offset: 36, 37.5, 44 mm
... The MALUCTM Total Hip Arthroplasty System (THA) is used for primary total hip replacement in skeletally mature individuals. modular CoCr and BIOLOX® delta femoral heads in various sizes and offsets, ...
Femoral stem length: 117.5, 79.5 mm
Femoral stem offset: 41.4, 32.2 mm
... patients. Conserving bone MiniHip is designed to provide the bone preserving benefits of hip resurfacing with the stability of traditional total hip replacement. With MiniHip, typically a mid-neck resection ...
Corin
... to total hip arthroplasty. REDUCED PROXIMAL LATERAL DESIGN The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, which facilitates ...
Trilliant Surgical
... Merete brought the BioBall® system onto the market as a “modular joint prosthesis system” at the end of the 1990s. It has become the “standard” in hip athroplasty. The titanium BioBall® adapter allows intra-operative ...
Femoral stem length: 114, 81 mm
Femoral stem offset: 50, 29 mm
CCD angle: 128, 133, 124 °
... A contemporary total hip arthroplasty system engineered for reproducibility, performance and efficiency. System Features Titanium Coating Delivers a press-fit into the acetabulum. Polished and Anodized distal segment with distinctive ...
Femoral stem length: 128, 149 mm
Femoral stem offset: 36, 38, 45, 50 mm
Femoral head diameter: 40 mm - 60 mm
... outcomes in cemented total hip replacement. The Avanteon® Hip System is the first total hip replacement system to be included in the pilot phase of Beyond Compliance. Key Features - Stem Four offsets ...
JRI Orthopaedics
CCD angle: 125, 135 °
... The Expersus stem is a hip stem prosthesis that allows either the cemented or the cementless version of the stem to be inserted with one set of instruments. In the cemented version, the Expersus stem is made of implant ...
Femoral stem length: 40, 50, 60, 70 mm
CCD angle: 125, 135 °
... The SMR 100's stem is a modular system designed for hip replacement in particular cases of dysplasia, osteotomies and fractures. The stem features 3 components: proximal, distal and locking screw. INDICATIONS Dysplasia; Osteotomy ...
Gruppo Bioimpianti
Acetabular cup diameter: 42 mm - 62 mm
Femoral head diameter: 28 mm - 36 mm
CCD angle: 135 °
... + Total hip prosthesis, is an operation for replacing a hip joint that has been damaged due to primary or secondary cause and has advanced osteoarthritis. + The total hip ...
Often used for trauma cases. Wide size range of outside diameter, inside diameter is 28 mm. Ideal in those cases when femoral head cannot be saved.
Femoral stem length: 130, 144, 150 mm
CCD angle: 135 °
... The stem Austin Moore offers one of the most simple and classic hip hemiarthroplasty solutions market in which the articular cartilage of the acetabulum is respected. The geometry of the section of the rods is of rectangular type with ...
Surgival
... Ankylosing spondylitis · Rheumatoid arthritis · Femoral head osteonecrosis · Osteoarthritis · Developmental dysplasia of hip ...
Irene Ortho
... A range of total hip implants including 6 versions of femoral stems (standard or laterlized, with or without colar, with or without cement), dual mobility cups and ceramic cups. ...
... 6 and 7 TI + HA coating 135° diaphyseal inclination 6° (9/11) taper ...
Femoral stem length: 16, 10 mm
Acetabular cup diameter: 46 mm - 66 mm
CCD angle: 127, 132 °
... The Cordera™ Hip System, is an uncemented, primary total hip replacement featuring an industry proven stem design. The implant system can be used with or without a pre-operative CT ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group