Product overviewThe Urinalysis Reagent Strips (Urine) are firm plastic strips onto which several separate reagent areas are affixed. The test is for the qualitative and semi-quantitative detection of one or more of the following analytes in urine: Ascorbic acid, Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite and Leukocytes.
Explain / PrincipleThe Rapid Response Drugs of Abuse Test Device detects drugs of abuse through visual interpretation of color development on the internal strip. Drug conjugates are immobilized on the test region of the membrane. During testing, the specimen reacts with antibodies conjugated to colored particles precoated on the sample pad. The mixture migrates through the membrane by capillary action and interacts with reagents on the membrane. If drug molecules are below cutoff, the antibody-colored particle conjugate binds to immobilized drug conjugates forming a colored band at the test region (negative). If drug molecules exceed the cutoff, they compete for antibody binding sites preventing formation of the colored band in the test region (positive). A colored band at the control region indicates proper specimen volume and membrane wicking.
Test parametersURS-10T, URS-11, URS-12MA
Instrument / Analyzer related parametersWavelengths: 558 nm, 635 nm, 720 nm
Test speed: Up to 120 tests/hour at continuous operation
Memory size: 1000 test results
Optional: 10, 11 or 12 parameters
Print: Thermal printer inside, with outer stylus printer interface
Host communication: PC connected with RS232
Language: English
Environment condition: 0-40°C, RH < 85%
Power supply: AC 220V (±15%), 50-60Hz
Power: ≤60W
Carton dimensions (L/W/H): 580 × 300 × 300 mm
Reagent details (read time | composition | detection limit / description)Ascorbic Acid (ASC) | 30 seconds | 2,6-dichlorophenolindophenol; buffer and non-reactive ingredients | Detects ascorbic acid as low as 5-10 mg/dL (0.28-0.56 mmol/L).
Glucose (GLU) | 30 seconds | Glucose oxidase; peroxidase; potassium iodide; buffer; non-reactive ingredients | Detects glucose as low as 50-100 mg/dL (2.5-5 mmol/L).
Bilirubin (BIL) | 30 seconds | 2,4-dichloroaniline diazonium salt; buffer and non-reactive ingredients | Detects bilirubin as low as 0.4-1.0 mg/dL (6.8-17 μmol/L).
Ketone (KET) | 40 seconds | Sodium nitroprusside; buffer | Detects acetoacetic acid as low as 2.5-5 mg/dL (0.25-0.5 mmol/L).
Specific Gravity (SG) | 45 seconds | Bromthymol blue indicator; buffer and non-reactive ingredients; poly (methyl vinyl ether/maleic anhydride); sodium hydroxide | Determines urine specific gravity between 1.000 and 1.030; correlates with refractive index method within ±0.005.
Blood (BLO) | 60 seconds | 3,3',5,5' tetramethylbenzidine (TMB); diisopropylbenzene dihydroperoxide; buffer and non-reactive ingredients | Detects free hemoglobin as low as 0.018-0.060 mg/dL or 5-10 Ery/µL in urine specimens with ascorbic acid < 50 mg/dL.
pH | 60 seconds | Methyl red sodium salt; bromthymol blue; non-reactive ingredients | Permits quantitative differentiation of pH values within the range of 5-9.
Protein (PRO) | 60 seconds | Tetrabromophenol blue; buffer and non-reactive ingredients | Detects albumin as low as 7.5-15 mg/dL (0.075-0.15 g/L).
Urobilinogen (URO) | 60 seconds | p-diethylaminobenzaldehyde; buffer and non-reactive ingredients | Detects urobilinogen as low as 0.2-1.0 mg/dL (3.5-17 μmol/L).
Nitrite (NIT) | 60 seconds | p-arsanilic acid; N-(1-naphthyl)ethylenediamine; non-reactive ingredients | Detects sodium nitrite as low as 0.05-0.1 mg/dL in urine with low SG and <30 mg/dL ascorbic acid.
Leukocytes (LEU) | 120 seconds | Derivatized pyrrole amino acid ester; diazonium salt; buffer; non-reactive ingredients | Detects leukocytes as low as 9-15 white blood cells Leu/µL in clinical urine.
Adulteration Test Strips (Specimen Validity Tests)Drug adulteration test strips identify whether a urine sample has been intentionally manipulated, contaminated or diluted. The six-in-one Adulteration Test Strips detect:
- Creatinine – checks for dilution; absence (<5 mg/dL) indicates specimen not consistent with human urine.
- Specific Gravity – checks sample dilution; normal human urine 1.003–1.030.
- Nitrite – detects common commercial adulterants that oxidize metabolites; normal urine contains no nitrite.
- Glutaraldehyde – identifies adulterants that disrupt immunoassay enzymes; not normally found in urine.
- pH – normal pH range 4.0–9.0; values outside may indicate tampering.
- Oxidants/PCC – detects oxidizing agents (bleach, hydrogen peroxide, pyridinium chlorochromate) used as adulterants.
Available formats- Dip strip (packaged 25 per canister).
- Also available in some multi-drug panel and integrated cup formats.
Caractéristiques / spécifications techniques- Analytes detected: Ascorbic acid, Glucose, Bilirubin, Ketone (acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes.
- Test parameters / models: URS-10T, URS-11, URS-12MA (referred collectively as URS series).
- Read times per parameter: from 30 seconds up to 120 seconds depending on reagent.
- Analyzer wavelengths supported: 558 nm, 635 nm, 720 nm.
- Throughput: up to 120 tests/hour continuous.
- Data memory: up to 1000 test results.
- Optional panel sizes: 10, 11 or 12 parameters.
- Printer: internal thermal printer, external stylus interface available.
- Host communication: RS232 to PC.
- Operating environment: 0–40°C; relative humidity <85%.
- Power: AC 220V (±15%), 50–60Hz; ≤60W power consumption.
- Packaging dimensions (carton): 580 × 300 × 300 mm.
- Formats available: dip strips (25 per canister), dipcards, cassette, multi-panel, urine cup formats.