1. Secondary care
  2. Orthopedic surgery
  3. Femoral intramedullary nail
  4. Shandong ShinvaUnited Orthopedic Company Limited
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Femoral intramedullary nail 4080101
proximal fixationrightleft

Femoral intramedullary nail - 4080101 - Shandong ShinvaUnited Orthopedic Company Limited - proximal fixation / right / left
Femoral intramedullary nail - 4080101 - Shandong ShinvaUnited Orthopedic Company Limited - proximal fixation / right / left
Femoral intramedullary nail - 4080101 - Shandong ShinvaUnited Orthopedic Company Limited - proximal fixation / right / left - image - 2
Femoral intramedullary nail - 4080101 - Shandong ShinvaUnited Orthopedic Company Limited - proximal fixation / right / left - image - 3
Femoral intramedullary nail - 4080101 - Shandong ShinvaUnited Orthopedic Company Limited - proximal fixation / right / left - image - 4
Femoral intramedullary nail - 4080101 - Shandong ShinvaUnited Orthopedic Company Limited - proximal fixation / right / left - image - 5
Add to favorites
Compare this product

Characteristics

Joint / bone
femur
Fixation
proximal fixation
Side
right, left
Materials
titanium
Length

Max.: 420 mm
(16.5 in)

Min.: 170 mm
(6.7 in)

Proximal diameter

9 mm, 10 mm, 11 mm, 12 mm
(0.4 in, 0.4 in, 0.4 in, 0.5 in)

Description

Product short info
Model Number: 4080101
Material: Titanium Alloy TC4
Application: The short (stub) nail is used for internal fixation of femoral intertrochanteric fracture and high subtrochanteric fracture. The long nail is used for internal fixation of low subtrochanteric fracture, femoral trochanteric fracture, femoral trochanter combined ipsilateral femoral shaft fracture, and pathological femoral fracture.

Product Introduction
The PFNA (Proximal Femoral Nail Anti-rotation) is an intramedullary fixation system designed for the surgical treatment of proximal femoral fractures, particularly unstable intertrochanteric and subtrochanteric fractures. The system uses a helical blade fixation mechanism to compact cancellous bone within the femoral head, providing rotational and angular stability while supporting fracture fixation in patients with reduced bone quality. Manufactured from Ti-6Al-7Nb titanium alloy, the PFNA combines mechanical strength with biocompatibility. The intramedullary nail incorporates multiple design features, including a 5° lateral offset, 1500 mm anterior bow, optional dynamic or static distal locking, and an elastic tip and groove design for controlled insertion and stress distribution.

Features
  • Helical Blade Fixation: The helical blade compacts cancellous bone during insertion, enhancing rotational and angular stability at the fracture site and increasing bone contact while minimizing bone removal.
  • Anti-Rotation Stability: Blade-based fixation is designed to resist rotational displacement of fracture fragments and maintain stable fixation within the femoral head.
  • Flexible Locking Options: Distal locking supports both dynamic and static locking modes allowing selection according to clinical requirements.
  • Titanium Alloy Construction: Manufactured from Ti-6Al-7Nb titanium alloy, providing mechanical strength and biocompatibility.
  • Secure Tension Pin Retention: Tail cap design retains the tension pin to help prevent unintended displacement or backing out.
  • Anatomical Configuration: Nail features a 5° lateral offset and 1500 mm anterior bow to correspond to femoral anatomy.
  • Elastic Tip and Groove Design: Facilitates insertion of the main nail and contributes to stress distribution along the implant.

Advantages
  • Enhanced Rotational Stability: Helical blade compaction provides rotational/angular stability suitable for unstable proximal femoral fractures.
  • Load-Sharing Fixation: Intramedullary nail shares mechanical loading with surrounding bone for stable fixation and stress distribution.
  • Adaptation to Poor Bone Quality: Blade compaction benefits fixation in osteoporotic or compromised bone.
  • Minimally Invasive Fixation: Intramedullary approach supports limited surgical exposure and reduced soft-tissue disruption.
  • Support for Early Mobilization: Stable internal fixation designed to facilitate postoperative rehabilitation according to surgeon protocol.

Application
  • Unstable intertrochanteric fractures
  • High and low subtrochanteric fractures
  • Femoral trochanteric fractures
  • Femoral trochanter combined ipsilateral femoral shaft fractures
  • Pathological femoral fractures
  • Complex multiple proximal femoral fracture patterns

Specifications (excerpt)
Short Nail
Diameter (mm) | Length (mm)
9 | 170, 200, 240
10 | 170, 200, 240
11 | 170, 200, 240
12 | 170, 200, 240

Long Nail — Left
Diameter (mm) | Length (mm)
9 | 300, 320, 340, 360, 380, 400, 420
10 | 300, 320, 340, 360, 380, 400, 420
11 | 300, 320, 340, 360, 380, 400, 420
12 | 300, 320, 340, 360, 380, 400, 420

Long Nail — Right
Diameter (mm) | Length (mm)
9 | 300, 320, 340, 360, 380, 400, 420
10 | 300, 320, 340, 360, 380, 400, 420
11 | 300, 320, 340, 360, 380, 400, 420
12 | 300, 320, 340, 360, 380, 400, 420

Notes
Material: Titanium alloy (Ti-6Al-7Nb) as indicated. Implant offers options for short and long nails, multiple diameters and lengths, and dynamic/static distal locking.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo