Cerebral vascular model PLSJXG00B
intracranialcirculus arteriosus Willisiibrain artery

Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery - image - 2
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery - image - 3
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery - image - 4
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery - image - 5
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery - image - 6
Cerebral vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / circulus arteriosus Willisii / brain artery - image - 7
Add to favorites
Compare this product

Characteristics

Area of the body
intracranial artery, circulus arteriosus Willisii, brain artery, intracranial, cerebral
Application
neurosurgery
Procedure
training, for neurovascular intervention, for embolization, for brain embolization
Simulated pathology / condition
with aneurysm, with intracranial aneurysm, stenosis
Type
adult
Material
silicone
Accessories
with blood vessels
Other characteristics
transparent, flexible
Length

1,040 mm
(40.9 in)

Width

490 mm
(19.3 in)

Height

190 mm
(7.5 in)

Description

Product overview
This intracranial vascular training model is made from highly transparent soft silica gel (food-grade silicone), hardness 30A. It is designed for surgical training, device performance testing and demonstration related to interventional diagnosis and treatment of intracranial arteries. The model reproduces cerebral arteries and clinical access pathways to simulate instrument navigation and procedural workflow.

Features
  • Includes anterior, posterior and middle cerebral arteries, basilar artery and the Circle of Willis, with integrated aneurysm and stenosis modules; also reproduces access vessels: left/right vertebral arteries, left/right common carotid arteries, thoracic aorta, iliac and femoral arteries. The internal carotid siphon includes two 180° bends and two 360° loops.
  • Supports testing and evaluation of endovascular devices such as guide catheters, guidewires, balloon dilation stents, self-expanding stents, coils, thrombectomy devices and embolic filters.
  • Enables simulation training for angiography, balloon angioplasty, stent and coil deployment, and thrombectomy to familiarize operators with procedural steps and device handling.
  • Modular design allows customized aneurysm and stenosis modules at various locations for testing, training and demonstration scenarios.
  • Dedicated insertion ports for radial, femoral and subclavian arteries accurately simulate clinical access routes and improve realism of procedural simulation.

Applicable operations and compatible devices
  • Surgical simulation: angiography, balloon angioplasty, thrombectomy simulation, stent and coil deployment.
  • Device compatibility/testing: guidewires, guide catheters, balloon dilation stents, coils, thrombectomy devices, embolic filters and similar neurovascular interventional instruments.

FAQ (selected)
  • Intended users and scenarios: Suitable for clinical skills training in hospitals, practical teaching in medical schools, and product testing and demonstrations by vascular intervention device manufacturers. Core users include medical students, interventional physicians and device R&D/testing personnel.
  • Supported procedures and devices: Supports angiography and balloon angioplasty training and testing of interventional devices such as guide catheters, guidewires and balloon dilation stents. Special insertion ports conform to clinical approaches.
  • Maintenance and customization: Easy to maintain; main body made of food-grade silicone, simple to clean. Supports customized aneurysm and stenosis modules and optional acrylic housing or illuminated base plate.

Technical specifications
  • PN: PLSJXG00B
  • Main material: Highly transparent soft silica gel (food-grade silicone), hardness 30A
  • Product size: model length 104 cm; width 49 cm; height 19 cm
  • Lead time: 15 days
  • Origin: Shanghai, China

Catalogs

No catalogs are available for this product.

See all of Shanghai Preclinic Medtech‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.