Internal carotid artery vascular model PLSJXG00B
intracranialcommon carotid arterythoracic aorta

Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 2
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 3
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 4
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 5
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 6
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 7
Internal carotid artery vascular model - PLSJXG00B - Shanghai Preclinic Medtech - intracranial / common carotid artery / thoracic aorta - image - 8
Add to favorites
Compare this product

Characteristics

Area of the body
internal carotid artery, intracranial, common carotid artery, thoracic aorta, artery, posterior cerebral artery, brain, cerebral, circulus arteriosus Willisii, brain artery, anterior cerebral artery, iliac artery, basilar artery, femoral artery, middle cerebral artery, vertebral artery, intracranial artery
Procedure
for teaching
Material
silica gel, silicone
Other characteristics
transparent, flexible
Length

1,040 mm
(40.9 in)

Width

490 mm
(19.3 in)

Height

190 mm
(7.5 in)

Description

Product overview
This intracranial vascular training model is manufactured from highly transparent soft silica gel (food-grade silicone), hardness 30A. It is designed for surgical training, device performance testing and demonstration for interventional diagnosis and treatment of intracranial arteries. The model reproduces cerebral vessels and clinical access routes to simulate instrument navigation and procedural workflow.

Features
  • Includes anterior, posterior and middle cerebral arteries, basilar artery and the Circle of Willis with integrated aneurysm and stenosis modules; reproduces major access vessels: left/right vertebral arteries, left/right common carotid arteries, thoracic aorta, iliac and femoral arteries. The internal carotid siphon includes two 180° bends and two 360° loops.
  • Supports testing and performance evaluation of endovascular devices such as guide catheters, guide wires, balloon-dilation stents, self-expanding stents, coils, thrombectomy devices and embolic filters.
  • Enables simulation training for angiography, balloon angioplasty, stent and coil deployment and thrombectomy to familiarize operators with procedural steps and device handling.
  • Modular design allows customization of aneurysm and stenosis modules at different locations to meet testing, training and demonstration requirements.
  • Dedicated insertion ports for radial, femoral and subclavian arteries accurately simulate clinical access routes and improve operational realism.


Applicable operations and devices
  • Surgical simulation: angiography, balloon angioplasty, thrombectomy simulation, stent and coil implantation.
  • Compatible for testing/demonstration of: guide wires, guide catheters, balloon-dilation stents, self-expanding stents, coils, thrombectomy devices and embolic filters.


FAQ (selection)
  • Target users and scenarios: Suitable for clinical skills training in healthcare institutions, practical teaching at medical schools and product testing/demonstration by vascular device manufacturers. Primary users: medical students, interventional physicians and R&D/testing personnel.
  • Supported procedures and devices: Supports angiography and balloon angioplasty training and testing of interventional devices such as guide catheters, guide wires and balloon-dilation stents. Insertion ports follow clinical approaches.
  • Maintenance and customization: Easy maintenance; main body made of food-grade silicone, simple to clean. Supports custom aneurysm and stenosis modules and options such as acrylic casing or illuminated base plate.


Drawings and images
Detailed product drawings and images are available on the product page.

Technical specifications
  • PN: PLSJXG00B
  • Main material: highly transparent soft silica gel (food-grade silicone), hardness 30A
  • Product size: length 104 cm; width 49 cm; height 19 cm
  • Lead time: 15 days
  • Origin: Shanghai, China

Catalogs

No catalogs are available for this product.

See all of Shanghai Preclinic Medtech‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.