... energy at ultrasonic frequencies (>400KHz) and very short wavelengths (~3mm) and is uniquely able to focus the energy into your sample. AFA controls the shearing forces that fragment nucleic acids to the selected size. The process is ...
Covaris Inc
... Dispensing Console , TEC2 800-C Cryo Console , TEC 2800-T Thermal Console and APT 290 Paraffin Trimmer as a complete embedding system . ...
Amos scientific
... DNA, as well as RNA, proteins and cells, using magnetic beads. Under optimized conditions, DNA selectively binds to the surface of the beads, while other contaminants stay in solution. Purified DNA can then be used directly in a wide ...
... workflows including NGS library preparation. It miniaturizes reactions from the µL to sub‑µL range using confined‑reaction and magnetic bead handling technologies to improve consistency and throughput. Runs are walk‑away: load samples ...
fully automated sample preparation systemISP series
... Overview
The ISP series Multifunctional
Sample
Preparation Workstation is a modular, upgradeable platform designed for evolving
sample workflows in food and pharmaceutical
laboratories. ...
Raykol Group
... Medical device for preparation and preservation of eye drops from haemocomponents ...
... to add any new samples for storage. Using a latest-generation barcode scanner, finderFLEX also rapidly scans any barcodes, QR codes and Data Matrix 2D codes, communicating directly with the LIS to ensure a systematic ...
... software in laboratories such as hospitals and blood stations Advanced barcode scanning system: •Active barcode scanning sample function, adjustable scanning speed, full table scan High stability: •Swiss ...
... MGISTP-3000 is a benchtop automated sample transfer processing system, which can complete transferring 96 samples from sealed tubes to a 96-well microplate in 40 minutes fast and accurately. In the pre-processing ...
MGI Tech
... Disposable Heater is an in vitro diagnostic medical device designed for the purpose of nucleic acid (DNA) amplification within samples inserted into wells, using isothermal amplification techniques, specifically Loop-mediated isothermal ...
... Specifications Instrument type: - Stand alone bench top Processing Capability: - 4 to 96 samples per run Processing Time: - Typically under 3 hours for 96 samples Temperature Control: - PID under software ...
... Q-Processor is an immunoassay sample processing device including washing, incubating, and processing for biological samples on allergy panels Specification Integrated PC 10 tests in one process ...
... automatic timers for test reactions to ensure the reliability of test results. Product Features ACCURACY: • Incubation system control temperature variation ≤± 0.1℃ EASE-OF-USE: • Simple temperature adjustment • Easy incubation ...
... testing More Unique System Features Q-STAIN X is a novel autostainer concept that can fit into nearly any histology laboratory. Whether the system is being utilized as the primary histology instrument ...
... items at will, convenient and flexible • It can be connected to LIS laboratory information system for seamless connection with subsequent test modules automatic processing system ...
... Automates Chromosome and MicroFISH Slide Preparation A liquid handling robot that automates preparation of chromosome and MicroFISH slides. For G-banding applications, it dispenses fixed cells in a humidity-controlled ...
SciGene
... adhesive features Easy operation with front panel Carousel button for rapid loading Automatic cleaning system No cross contamination Secure slide fixation within the staining chamber Easy Setting of Staining Method ...
Labtron Equipment
automated sample preparation systemCNT360-M1
... Diagnosis is missed by an inch, and treatment is a thousand miles away. Laboratory diagnoses can influence more than two-thirds of medical decisions. Innovative solution laboratory solutions for accurate and timely diagnosis ...
... It provides a single platform for all GC sample preparation. Cryogen-free analyte trapping provides high sensitivity by delivering a sharp, concentrated band of vapour to the GC. It is the only system ...
SepSolve
... Automated NGS Library Preparation System (ELPS-01) developed by MyGenostics Inc. is used for library preparation and target capture before high-throughput sequencing (NGS). The system ...
MyGenostics Inc.
... Fluorecence Assay on Glass. UNIQO is the new high-performance automated system for the IFA procedure, from slide preparation to test reading and validation. It provides laboratories with an all-in-one ...
VISIA Lab S.r.l.
Throughput: 32 p/h
... Microfluidic technology is the process of analyzing samples in biology, chemistry, medicine and other fields, including preparation, reaction, separation, detection and other basic units integrated into a micron-scale ...
... selectable options. SMU - Horizontal type Reagents applied method - Injection Reagent amount per cycle - Targeted samples only Heating method - Circulating heated air Dimensions - 51 x 55 x 27 cm Weight - 23 kg (51 lbs) Warranty ...
Medschenker
... staining procedures. Easy to use. ♦ Equipped with touch-screen display. ♦ Environmental friendly. Special hydraulic control system can prevent liquid evaporation, reduce reagent consumption and air pollution. ♦ Compact size, about ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group