- Laboratory >
- Laboratory medicine >
- Rapid test
Rapid tests
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Result display time: 17 min
Specificity: 83.9 % - 100 %
Sensitivity: 80 % - 94 %
... PATHFAST™ TB LAM Ag test is a product for in vitro diagnostic use with the PATHFAST™ automated analyser for the quantitative measurement of lipoarabinomannan (LAM) in human sputum. PATHFAST™ TB LAM Ag test is intended ...
... results. No laboratory training required. Clinical Significance The Viral Respiratory Tract Infections (VRI) test offers a rapid and comprehensive solution, capable of detecting 10 different viral respiratory infections, ...
Randox Laboratories
... The new SARS-CoV-2 rapid test is a rapid real time PCR test, providing a clear and concise result in a timely manner, enabling patients to take the recommended safety precautions as quickly ...
Randox Laboratories
... A rapid CE marked real-time PCR cartridge detecting SARS-CoV-2 from up to 5 pooled samples simultaneously, providing clear and concise results in 39 minutes. ...
Randox Laboratories
Specificity: 97.6, 99.2, 98.5, 98.9, 96.8 %
Sensitivity: 99.2, 91.3, 98.5, 96, 100 %
STIs are on the rise. Chlamydia (CT) and gonorrhea (NG) can have serious long-term consequences including pelvic inflammatory disease (PID), ectopic pregnancy and infertility.1 Accurate testing and treatment are critical to protecting sexual and reproductive ...
Hologic
... ReliaFlow™ absorbent pads collect the liquid processed through the strip by capillary action, offering consistent absorbency for test reproducibility. Our absorbent pads are usually made of high quality cotton fibers. The newly ...
Ahlstrom-Munksjö
colorectal cancer rapid screening testCologuard Plus®
... sample
Comparison (summary table)
Screening
test feature | Cologuard Plus | Colonoscopy | FIT (Fecal Immunochemical
Test) | FOBT (Fecal Occult Blood
Test) | Blood
test
Noninvasive ...
Abbott Diagnostics
Result display time: 10 min
Anyone who handles hazardous drugs (HDs) during transportation, preparation, administration or waste disposal may be at risk. A Canadian study of six hospitals found that frequently contacted surfaces at every stage of the hospital medication system had ...
BD
Sample volume: 0.01 ml
... cyclers MammaTyper® precisely quantifies expression of HER2, ER, PR and Ki-67 mRNA MammaTyper® is a molecular diagnostic test for quantitative determination of the four key biomarkers used in the subtyping of breast cancer. Human ...
Specificity: 95 %
Sensitivity: 95 %
... 4Dx Plus Test is the most accurate solution available for detecting vector-borne disease1–3—now with IDEXX DecisionIQ for added clarity in determining next steps. Store tests at room temperature for up to 6 months ...
Idexx Laboratories
Result display time: 150 min
... intervals to assess the efficacy and safety of the treatment.4-7 The Solution The Xpert BCR-ABL Ultra is a quantitative test for BCR::ABL major breakpoint (p210) transcripts that provides highly sensitive and on-demand molecular ...
Cepheid
Result display time: 5 min
Sample volume: 0.04 ml
... Cholestech LDX™ System. BENEFITS Flexible: fingerstick or venous whole blood CLIA-waived SPECIFICATIONS 1 box of 10 tests ...
Abbott
Result display time: 1 min - 5 min
... Ultra sensitive Our most sensitive digital pregnancy test detects the pregnancy hormone, hCG, with a sensitivity of 10mIU/ml. Ultra early Results from 6 days before your missed period (which is 5 days before your expected period). ...
Clearblue
Sample volume: 0.2 ml
Specificity: 99.8 %
Sensitivity: 94.2 %
... Make timely and potentially life-saving interventions in meningitis and encephalitis cases with rapid, comprehensive results from this multiplex molecular test. Make Every Second Count Distinguishing bacterial ...
Result display time: 39 min
Specificity: 100 %
Sensitivity: 98 %
... Bosch has developed a new rapid test for its Vivalytic analysis device to detect the SARS-CoV-2 pathogen. The test provides a reliable result in 39 minutes and is currently the fastest PCR test ...
Bosch Healthcare Solutions
Result display time: 2 h - 3 h
Specificity: 94.9 %
Sensitivity: 99.3 %
... resistant isolates. ELITechGroup Microbiology proposes a reliable Rapid Polymyxin NP test to detect polymyxins (polymyxin E or Colistin, polymyxin B) resistant Enterobacteriaceae. This test is based ...
ELITech Group
Result display time: 30 min
... The Promonitor family of tests measures both drug levels and anti-drug antibody levels with validated ELISA assays to complement biological therapies for drug monitoring. Testing for drug bioavailability and immunogenicity: ...
Result display time: 5 min
... This is a true one–step test and is the first rapid strep A test waived under CLIA '88. Features & benefits Test and treat in the same office visit with results in only 5 minutes. One ...
Quidel
Result display time: 3 h
... The PG-Seq™ Rapid kit v2 has been developed to analyze picogram quantities of DNA (single/multi-cells or low template DNA) from an embryo biopsy for preimplantation genetic testing. The PG-Seq™ Rapid kit v2 utilizes whole ...
... departments.Open reagent options: the matching ATP Quickswab swabs by Tianlong are recommended to ensure the accuracy of test results. Rapid detection: 10s per sample. Automated operation: 3.5-inch color screen, ...
Xian Tianlong Science and Technology
... The Novel Coronavirus (2019-nCoV) Nucleic Acid Diagnostic Kit (PCR-Fluorescence Probing) is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from SARSCoV-2 in nasopharyngeal swabs, oropharyngeal (throat) ...
Sansure Biotech
... T-SPOT.COVID test is intended for use as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, specifically the T cell response. It has been developed using the standarised T-SPOT Technology. The T-SPOT.COVID ...
Oxford Immunotec Ltd.
... questions and reminder texts and calls to support completion of the test. This proprietary technology proved to be a breakthrough in the development of the multitarget stool DNA test. Our scientists needed to first ...
Result display time: 5 min
... b>
- 022704 MedGyn Pregnancy HCG Cassette Urine Test (25/Box)
- 022705 MedGyn Pregnancy HCG Combo Urine/Serum Test (25/Box)
- 022706 MedGyn Pregnancy HCG Dipstick Urine Test (25/Box)
Product ...
Result display time: 10 min
... (MDMA) , Oxycodone (OXY) , Phencyclidine (PCP) , Propoxyphene (PPX) , K2, Alcohol(ALC) INTENDED USE The Saliva Drug Rapid Test (Colloidal Gold Method) is a lateral flow chromatographic immunoassay for the qualitative ...
Hangzhou Singclean Medical Products
Result display time: 5 min - 5 min
... (THC 25), Marijuana(THC), Tricyclic Antidepressants (TCA),Tramadol (TML), Tramadol (TML300). Including specimen validity test (S.V.T.) for Oxidants/Pyridinium Chlorochromate(OX/PCC),specific gravity(SG), pH, Nitrite(NIT), Glutaraldehyde(GLUT) ...
Hangzhou Singclean Medical Products
Result display time: 5 min - 5 min
... validity test (S.V.T.) for Oxidants/Pyridinium Chlorochromate(OX/PCC),specific gravity(SG), pH, Nitrite(NIT), Glutaraldehyde(GLUT) and Creatinine(GRE). Intended use The Multi-drug One Step Test Kit (Colloidal ...
Hangzhou Singclean Medical Products
Result display time: 10 min
Specificity: 90.1 %
Sensitivity: 84.3, 98.3 %
... , wheat, barley, kamut, spelled, rye, spelled and triticale). Benefit of the test Rapid support to healthcare personnel WHO IS THIS TEST FOR? CELIAC RAPID TEST ...
SENTINEL DIAGNOSTICS
Result display time: 5 min
Specificity: 96 %
... WHO IS THIS TEST FOR? C-REACTIVE PROTEIN RAPID TEST is useful in assisting the diagnosis and therapeutic monitoring, as it helps to determine the origin of a possible infection. TECH SPECS C-REACTIVE ...
SENTINEL DIAGNOSTICS
Result display time: 5 min
Specificity: 99 %
... colitis, diverticula, rhagades, hemorrhoids or tumor. Benefit of the test Easy to use Rapid support to healthcare personnel WHO IS THIS TEST FOR? BOWEL FOB RAPID TEST ...
SENTINEL DIAGNOSTICS
Result display time: 15 min
Specificity: 100 %
Sensitivity: 100 %
... Shanghai Kehua Bio-Engineering Co., Ltd.
Shanghai Kehua Bio-engineering
Result display time: 15 min - 30 min
... The Diagnostic Kit for Antibody to T. Pallidum from KHB is a rapid test for the detection of antibodies of Treponema Pallidum (TP) in human serum, plasma, whole blood as an aid in the diagnosis of syphilis infection. ...
Shanghai Kehua Bio-engineering
Result display time: 30 min
The Diagnostic Kit for Hepatitis C Virus Antibody from KHB is used for the in vitro qualitative detection of antibodies to hepatitis C virus in human serum, plasma or whole blood samples. This product is intended for use as an aid to detect antibodies ...
Shanghai Kehua Bio-engineering
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group