Sample volume: 0.005 ml
... Robust Good reproducibility Built-in check for sample quality and normalization. Details Method: Multiplex real- time methylation-specific PCR assay Target: Human genes ASCL1 and ZNF582 Built-in reference ...
... AASLD) recommendations for an FDA-approved quantitative or qualitative nucleic acid test (LoD ≤25 IU/mL) to determine sustained virological response (SVR). It employs real- time transcription-mediated ...
Hologic
Result display time: 90 min
... 50%1 HIV viral load tests that can be deployed beyond centralized laboratories are needed to expand access to the standard of care.1 The Solution The Xpert HIV-1 Viral Load XC test is an on-demand quantitative ...
Cepheid
urinary disease test kitUroGen ELITe MGB®
Specificity: 93.6 % - 100 %
Sensitivity: 98.7 % - 100 %
... archiving - Minimal hands-on time: - Less than 2 minutes per sample from extraction to result analysis - Complete STI menu: - STI PLUS ELITe MGB® Kit, HSV1/2 ELITe MGB® Kit, HR – HPV ELIte Panel and ...
ELITech Group
... Real- Time Cell Death Assay With Multiplexing Compatibility Accurate cytotoxicity determination in exposures out to 72 hours Flexible protocol allows kinetic analysis or endpoint determination Multiplex with luminescent ...
Result display time: 0 min - 120 min
Specificity: 95 % - 100 %
... detection of Vancomycin-Resistant Enterococcus (VRE) in
real-
time PCR
Kit size: 24
tests
Reference: 1N040
Technical specifications
- Technology: Lyophilized
... which can neutralize polybrene, the
test result is interpreted as “Negative”.
If RBC is sensitized by the corresponding antibody, agglutination will be produced by polybrene and shall not be dispersed, the
test result ...
... BTV pan/4 RT-PCR Kit from INDICAL allows for safe identification of RNA from all 29 known bluetongue virus serotypes, plus separate detection of the BTV serotype 4 (BTV-4). The kit contains all of the reagents ...
INDICAL BIOSCIENCE GmbH
Result display time: 30 min
... removed to yield pathogen nucleic acids that are ready for use in downstream applications, such as
real-
time PCR and RT-PCR.
- Developed and validated for a broad range of veterinary sample matrices, e.g. whole
INDICAL BIOSCIENCE GmbH
... 60 mins (Availability/distribution: Outside the U.S. and Canada) INDICAL's bactotype C. burnetii PCR Kit is a highly sensitive and specific test for detection and quantification of DNA from Coxiella burnetii (C. burnetii) ...
INDICAL BIOSCIENCE GmbH
Specificity: 99.1 %
Sensitivity: 98.3 %
... In vitro diagnostic medical device for screening of human papillomavirus (HPV). The careGENETM HPV screening kit is test reagents for screening of human papillomavirus (HPV). In conjunction with ...
Result display time: 83 min
Sample volume: 0.01 ml
Specificity: 100 %
... careGENE™ COVID-19 RT PCR kit is an in vitro diagnostic medical device for qualitative detection of coronavirus disease (COVID-19) from RNA extracted from human nasoparyngeal swab, oropharyngeal swab, and sputum using real- time ...
Result display time: 15 min
...
Related products
Related veterinary ...
... for downstream applications such as STR, PCR and real- time PCR. specification Storage And Stability : Store at Room Temperature Packing : 72 tests / Kit Contents Pre-Filled ...
RBC Bioscience
... Enterica/Shigella Nucleic Acid Multiplex Detection Kit is intended for the qualitative detection of Salmonella Enterica and Shigella nucleic acid by Real- time Polymerase Chain Reaction ...
Xian Tianlong Science and Technology
... genus of the Poxvlridae family. Polymerase chain reaction (PCR) is the preferred laboratory test grven its accuracy and sensitivity. We offer the real- time PCR-based detection solutions to detect the ...
BEIJING APPLIED BIOLOGICAL TECHNOLOGIES
... The Influenza A/B and Respiratory Syncytial Virus Detection Kit (Fluo-rescence PCR) is a real- time RT-PCR test for the simultaneous in vitro qualitative detection and ...
Zhejiang Orient Gene
Specificity: 99.3, 96.9, 98.9 %
... Device of Mycobacteria Nucleic Acid Detection ABI 7700 real- time PCR system ABI 7500 real- time PCR system FQD-96A Fluorescent PCR Instrument Eppendorf ® Mastercycler ® ep real ...
... ) simultaneously. General Specification Precision: CV <1% LoD: 0.5 ng/μL Packing Specifications 24 tests/ kit - 48 tests/ kit ...
Yaneng Bioscience (Shenzhen) Co., Ltd.
... the detection and identification of 25 gastrointestinal pathogens using one-step real- time RT-PCR Allplex™ Gastrointestinal Panel Assays is a multiplex one-step real- time RT-PCR assay ...
Seegene
Result display time: 67 min
... cross-reactivity with other pathogens. Convenient detection: 67 min amplification Non-closed equipment required: any of real- time PCR instruments with FAM and VIC channels Cost-efficient shipping and Eco-friendly: ...
... 2+16 HPV TEST KIT-Lyophilized Version Predictor of Cervical Cancer This kit is intended to qualitatively detect the deoxyribonucleic acid (DNA) of 18 types of human papillomavirus (HPV) in women's ...
... infant during pregnancy or childbirth, or through blood transfusions or shared needles. STD I(CT/NG/UU) Multiplex Real- time PCR Kit is designed for detection of DNA of Chlamydia trachomatis (CT), Neisseria ...
Result display time: 70 min
... Chlamydia Trachomatis/Ureaplasma Urealyticum/Neisseria Gonorrhoeae DNA Diagnostic Kit (PCR-Fluorescence Probing) is a qualitative in vitro test for simultaneous detection of Chlamydia Trachomatis, Ureaplasma Urealyticum ...
Sansure Biotech
Result display time: 3 min
Sample volume: 0.035 ml
Specificity: 93 %
... solution for the detection and surveillance of COVID-19 infection. En-swer™ COVID-19 RT-PCR Kit detects the presence of SARS-CoV-2 virus itself through real- time reverse-transcription polymerase chain ...
... AccuPower® HCV Quantitative RT-PCR Kit is an in vitro diagnostic kit designed for the quantification of hepatitis C virus (HCV) RNA in human samples such as serum and EDTA-plasma through real- time ...
Bioneer Corporation
... internal control has been integrated into the kit in order to check PCR inhibition. The amplification data of the internal control is detected with the HEX filter depending on the Real- Time PCR system ...
... control targeting the human conserved gene monitor the sample collection, sample handling and real- time PCR process to avoid false-negative results.The kit is a fully premix lyophilized system, which ...