Product overviewMasters PARKWAY SOFT is a microcatheter intended for selective vascular access and contrast injection in endovascular procedures. It is offered in straight and angled tip configurations and multiple usable lengths to suit intracranial navigation.
Key specifications- O.D. (Distal/Proximal): 0.66/0.94 mm (1.98/2.8 Fr)
- I.D. (Distal/Proximal): 0.52/0.55 mm (0.020/0.022 in)
- Tip shape: Straight or Angle
- Maximum guidewire: 0.46 mm (0.018 in)
- Usable length options: 105 cm, 125 cm, 150 cm
- Coating length: 65 cm (100 cm for 150 cm usable length)
- Dead space volume: 0.43 ml / 0.47 ml / 0.53 ml depending on variant
Ordering information- Masters PARKWAY SOFT — Catalog No.: WMST105-18PWSF; Usable length: 105 cm; O.D.: 0.66/0.94 mm; I.D.: 0.52/0.55 mm; Max. GW: 0.46 mm; Coating length: 65 cm; Tip: Straight; Dead space: 0.43 ml; Iodine 300 mg/ml flow rate: 2.6 ml/s; Iodine 370 mg/ml flow rate: 1.5 ml/s
- Masters PARKWAY SOFT — Catalog No.: WMST45A-18PWSSF; Usable length: 105 cm; O.D.: 0.66/0.94 mm; I.D.: 0.52/0.55 mm; Max. GW: 0.46 mm; Coating length: 65 cm; Tip: Angle; Dead space: 0.43 ml; Iodine 300 mg/ml flow rate: 2.6 ml/s; Iodine 370 mg/ml flow rate: 1.5 ml/s
- Masters PARKWAY SOFT — Catalog No.: WMST125-18PWSF; Usable length: 125 cm; O.D.: 0.66/0.94 mm; I.D.: 0.52/0.55 mm; Max. GW: 0.46 mm; Coating length: 65 cm; Tip: Straight; Dead space: 0.47 ml; Iodine 300 mg/ml flow rate: 2.0 ml/s; Iodine 370 mg/ml flow rate: 1.0 ml/s
- Masters PARKWAY SOFT — Catalog No.: WMST45A-18PWSSF; Usable length: 125 cm; O.D.: 0.66/0.94 mm; I.D.: 0.52/0.55 mm; Max. GW: 0.46 mm; Coating length: 65 cm; Tip: Angle; Dead space: 0.47 ml; Iodine 300 mg/ml flow rate: 2.0 ml/s; Iodine 370 mg/ml flow rate: 1.0 ml/s
- Masters PARKWAY SOFT — Catalog No.: WMST150-18PWSF; Usable length: 150 cm; O.D.: 0.66/0.94 mm; I.D.: 0.52/0.55 mm; Max. GW: 0.46 mm; Coating length: 100 cm; Tip: Straight; Dead space: 0.53 ml; Iodine 300 mg/ml flow rate: 1.6 ml/s; Iodine 370 mg/ml flow rate: 0.8 ml/s
Notes / Test conditionsAll data above were obtained using the company's standardized test methods and may differ from industry-standard tests. Actual flow rates can be lower due to contrast medium viscosity and clinical conditions. Dead space volume is measured with the intended medical equipment connected.
Flow rate — Test parametersTest settings: contrast medium temperature 37°C; linear rise time 0.3 s; flow rate test condition: iodine content 300 / 370 mg/ml at 3.0 ml/s; test volume: 10 ml.
Technical specifications- O.D. (Distal/Proximal): 0.66/0.94 mm (1.98/2.8 Fr)
- I.D. (Distal/Proximal): 0.52/0.55 mm (0.020/0.022 in)
- Tip shape: Straight or Angle
- Maximum guidewire: 0.46 mm (0.018 in)
- Usable lengths: 105 cm, 125 cm, 150 cm
- Coating length: 65 cm (100 cm for 150 cm usable length)
- Dead space volume: 0.43 ml / 0.47 ml / 0.53 ml depending on variant
- Category: Microcatheter