Product description The Hi-Flo XLT range of glass fiber bag filters features moulded plastic frames for HVAC and cleanroom prefiltration applications. Low initial pressure drop and high dust-holding capacity enable reduced energy use and less frequent filter changes. Available across ISO 16890 efficiencies (ePM10, ePM2.5, ePM1) and multiple frontal sizes and pocket depths (370/520/640 mm).
Key features - Low initial pressure drop and reduced energy consumption
- Extended operating life for improved total cost of ownership (TCO)
- Reduced labour cost due to less frequent filter replacements
- Conical, tapered pocket shape for improved airflow distribution
- Moulded plastic frame compatible with standard housings
Product variants (table) Item | ISO 16890 | Filter Class EN779 | Width (mm) | Height (mm) | Depth (mm) | Airflow (m3/h) | Pressure drop Initial (Pa) | Energy (kWh/year) | Energy Class (Eurovent)
1060 592x592x640-10 | ePM10 60% | M5 | 592 | 592 | 640 | 3400 | 35 | 474 | A+
1060 490x592x640-8 | ePM10 60% | M5 | 490 | 592 | 640 | 2800 | 35 | | A+
1060 287x592x640-5 | ePM10 60% | M5 | 287 | 592 | 640 | 1700 | 35 | | A+
1060 592x592x520-10 | ePM10 60% | M5 | 592 | 592 | 520 | 3400 | 40 | 568 | A
0160 592x592x640-10 | ePM1 60% | F7 | 592 | 592 | 640 | 3400 | 65 | 811 | A+
0185 592x592x640-10 | ePM1 85% | F9 | 592 | 592 | 640 | 3400 | 120 | 1474 | C
2550 592x592x640-10 | ePM2,5 50% | M6 | 592 | 592 | 640 | 3400 | 55 | 748 | A
Badges & certifications - Efficiency guarantee: stable mechanical filtration without electrostatic charge
- ISO 16890 classification (tested and performance classified)
- Eurovent certified filters (selected models)
- Environmental Product Declaration (EPD) available for some variants
Notes The Hi-Flo XLT range includes numerous full-size and modular bag-filter modules in various frontal dimensions, pocket depths and efficiency classes (M5, M6, F7, F9 / ePM10, ePM2.5, ePM1). The table above shows representative entries and core parameters per variant: designation, ISO class, EN779 class, dimensions (W x H x Depth in mm), nominal airflow (m3/h), initial pressure drop (Pa), annual energy (kWh/year) and Eurovent energy class.
Technical specifications - Application: Air handling units (AHU), HVAC and prefiltration for cleanrooms
- Frame: Moulded plastic
- Media: Glass fiber
- Max temperature (°C): 70
- Relative humidity: 100%
- Max final pressure drop (EN 13053): initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is lower)
- Standard dimensions: Filter front dimensions according to EN 15805
- Installation options: Front and side access housings and frames available
- Max airflow: 1.25 x nominal flow