Product IntroductionThe distal posterolateral tibial T-shaped universal variable-angle locking plate (model 4034013) is designed for internal fixation of distal tibial fractures. It provides angular-stable fixation and support for fracture fragments while minimizing soft tissue irritation through a low-profile anatomical contour.
Features- 30° conical polyaxial locking holes allowing screw angulation up to 15° from the hole axis in multiple directions.
- Spherical threaded screw heads to ensure an angular-stable screw-plate interface.
- Self-tapping screw compatibility for efficient insertion.
- Anodized surface finish for corrosion resistance and biocompatibility.
- Compatibility with locking screws (II) and cannulated screws (III); typical screw size: 2.7 mm.
- Low-profile anatomical T-shaped design with rounded edges and polished surface to reduce soft tissue irritation.
Advantages- Polyaxial flexibility: adjustable screw trajectories to match fracture anatomy.
- Secure locking interface reduces the risk of screw loosening.
- Versatile screw placement options adapt to varied fracture patterns, including comminuted and osteoporotic bone.
- Rotational stability through multi-screw fixation.
- Simplified surgical workflow: polyaxial locking does not require additional sleeves or inserts.
- Reduced soft tissue interference due to low-profile anatomical contour.
Indications- Distal tibial fractures
- Tibial plateau fractures
- Comminuted fractures
- Intra-articular and extra-articular fractures
- Tibial shaft fractures
- Osteoporotic fractures
- Particularly suitable for posterolateral tibial fractures and cases requiring polyaxial screw fixation
Specifications / Technical tableModel Number | Spec.(mm) | Compatible screws
4034013 | 4 Holes × 72 | 2.7 mm VA Locking Screws; 2.7 mm Cortical Screw
4034013 | 6 Holes × 90 | 2.7 mm VA Locking Screws; 2.7 mm Cortical Screw
Technical specifications- Material: TA3G pure titanium; TC4 titanium alloy
- Application: Internal fixation of distal posterolateral tibial fractures
- Polyaxial locking system: 30° conical holes allowing up to 15° screw angulation from hole axis
- Screw compatibility: locking screws (II) and cannulated screws (III); typical example: 2.7 mm VA locking screws and 2.7 mm cortical screws
- Model reference: 4034013 (available in 4 Holes×72 and 6 Holes×90)
- Finish: Anodized surface for corrosion resistance
- Design: Low-profile anatomical T-shaped plate with rounded edges and polished surface to reduce soft tissue irritation