Product IntroductionThe Variable‑Angle Medial Distal Tibia Locking Plate 4034006 is intended for internal fixation of medial distal tibial fractures. The anatomically pre‑contoured plate provides stable buttress support while reducing the need for extensive soft tissue exposure. The plate incorporates 30° conical variable‑angle locking holes enabling screw angulation up to ±15° from axis, allowing screw trajectories to be adapted to fracture morphology and fragment position. Manufactured from TA3G pure titanium or TC4 titanium alloy, the plate features a low‑profile polished design with rounded edges to minimize soft tissue irritation. It is compatible with variable‑angle locking screws and conventional cortical screws for different fixation strategies.
Features- Variable‑angle locking holes (±15°): Allow adjustment of screw trajectory to fracture anatomy and fragment placement.
- Combination compression/locking holes: Support both compression and locking fixation techniques.
- Low‑profile anatomical design: Pre‑contoured plate with rounded, polished edges to limit soft tissue interference.
- Multiple fixation options: Compatible with 2.7 mm and 3.5 mm variable‑angle locking screws, standard locking screws and 3.5 mm cortical screws.
- Provisional K‑wire holes: Enable temporary fixation and fragment positioning during reduction.
- Titanium construction: TA3G pure titanium or TC4 alloy with anodized surface for biocompatibility and durability.
Advantages- Adjustable screw trajectories via ±15° variable‑angle range for tailored fixation to fracture pattern.
- Angular‑stable construct through multi‑directional locking for enhanced fixation in varied fracture configurations.
- Supports minimally invasive and open reduction techniques by reducing periosteal and soft tissue disruption.
- Flexible fixation strategy combining variable‑angle locking and compression as required.
- Reduced soft tissue irritation due to low‑profile geometry and rounded, polished edges.
Indications- Medial distal tibial fractures, including pilon and medial malleolar fractures.
- Distal tibial metaphyseal fractures with articular extension.
- Fractures requiring buttress support of the medial tibia or malleolus.
- Osteoporotic or comminuted fractures benefiting from variable‑angle fixation.
- Cases suitable for minimally invasive or open reduction and internal fixation.
Specifications (table)Model Number | Spec.(mm) | Compatible screws
4034006 | 4 Holes×112 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 6 Holes×142 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 8 Holes×172 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 10 Holes×202 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 12 Holes×232 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 14 Holes×262 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 16 Holes×292 Left | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 4 Holes×112 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 6 Holes×142 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 8 Holes×172 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 10 Holes×202 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 12 Holes×232 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 14 Holes×262 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
4034006 | 16 Holes×292 Right | 2.7/3.5 mm VA Locking Screws; 3.5 mm Cortical Screw
Technical specifications- Material: TA3G pure titanium or TC4 titanium alloy
- Application: Internal fixation of medial distal tibial fractures
- Variable‑angle locking: 30° conical holes supporting ±15° screw angulation
- Compatible screws: 2.7 mm and 3.5 mm variable‑angle locking screws; 3.5 mm cortical screws
- Plate design: Pre‑contoured anatomical shape, low‑profile, rounded and polished edges
- Fixation options: Combination compression/locking holes; provisional K‑wire holes for temporary fixation
- Available variants: Multiple left/right plate lengths (4 to 16 holes as listed above)