- Dental >
- Dental practice >
- Cephalometric X-ray system
Cephalometric X-ray systems
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... than a minute. X-Mind® trium provides 4 different types of field of view going from 40 x40mm to 110 x80mm. The smallest field of view (Ø40 x40) allows ultra-high-resolution images (75 ...
... workflow. The ergonomic
cephalometric head support with integrated Frankfurt plane reference improves patient stability and comfort, reducing the risk of retakes due to motion artifacts.
Design and usability
The
system ...
... obtains the optimal image. Digital Direct Automatic Exposure (DDAE) DDAE controls the X- ray tube voltage (kV) and current (mA) simultaneously by detecting X- rays passing through the ...
... imaging from Vatech. This will increase your diagnostic accuracy for improved treatment planning and patient satisfaction 8 x8 images enable fundamental diagnoses and treatment planning, including both the maxillary and mandibular areas, ...
VATECH Networks
... without a mirror ensures personal eye contact and facilitates communication with the patient. Panoramic X- ray programs With a total of 17 X- ray programs, you are well equipped for ...
Voxel size (μm3): 75 µm
... unit can be used without a chin cup when Planmeca CALM® motion correction is applied.
Image quality and X‑ray tube
The
system uses a tube voltage up to 120 kV to improve contrast and ...
Planmeca
... specialist system with a large volume and high image quality for practices with a broad treatment offering. Developed together with dentists and clinicians, Axeos provides the fullest range of functions out of all Dentsply Sirona extraoral ...
... evaluation of dental implant. FOV12 x10cm Covers from lower jawbone to maxillary sinus, and airway. Suitable for general and local diagnostics, and preoperative evaluation of dental implant. FOV15 x11cm Support the HD ...
Voxel size (μm3): 70 µm
... name: I-Max 3D XPRO
Voxel size (μm3): 70 µm
... reduced dose), 24
x 24 cm, 24
x 18 cm (reduced dose), 30
x 24 cm, 30
x 18 cm (reduced dose), carpus 18
x 24 cm.
Software
QuickVision 3D implant ...
... Automatic Layers Integration System
Voxel size (μm3): 65, 140, 180 µm
... Large FOV (Field of View) One product with various FOV settings from 5 X5 to 20 X11, depending on purpose and application. With GT300's wide-area FOV, you can obtain a wide-angle image in one shot without the need for ...
Genoray
Voxel size (μm3): 0.08 µm
... SMART POSITIONING SYSTEM By creating a database based on the patient-specific exposure conditions and positioning of the previous images, you can create fast and convenient scans without any additional adjustments. 4-ln-1 X- Ray ...
Genoray
Voxel size (μm3): 0.08 µm
... optimal images. Smart Moving Chinrest According to the scanning areas, the system will automatically adjust the chinrest and help more accurate positioning. 4-ln-1 X- Ray System By ...
Genoray
... enables you to easily position the patient, visually choose the areas of interest with your 3D, panoramic or cephalometric settings and preview the X- ray image shortly after exposure without opening any ...
DEXIS
Voxel size (μm3): 75, 68 µm
... orthodontics and bone diagnosis. The 2D and CEPH module provides a high definition overview and teleradiography, optimised by advanced filters such as MultiLayer PAN and Super PAN, while the X-Safe algorithm automatically ...
Voxel size (μm3): 50, 25 µm
... panoramic imaging, fitting the patient's dental arch Easy-to-target scan area Six positioning lasers with face-to-face communication to posit precisely X-type base is convenient for wheelchair-bound patients 10"LED ...
Voxel size (μm3): 75 µm
... Panoramic, CBCT (3D), Cephalometric (optional), 3D object scans
Carestream Dental
... The best technology, the best efficiency! High-end 5 in 1 Cone Beam CT which can create a 3D virtual patient. RAYSCAN Studio boasts the highest performance and efficiency among RAYSCAN Series. Easily create a 3D virtual patient and apply it to various ...
Ray
Voxel size (μm3): 50 µm
... Ultra HD 2D)
NewTom
... >
Technical specifications
- Commercial name: Hyperion X9 Pro FullView
- System type: 4-in-1 extraoral imaging system (panoramic, CBCT 3D, cephalometric integration,
MyRay
... trno4.0- 10.4sec0.3/0.8 Sec0.3/0.8 Sec Visible X- ray Guide Through LED light shining on patient s lace, you can take x- ray only on necessary région Pulsed X- ray Onty ...
... ProVecta S-Pan Cephalometric X-RayThe ProVecta S-Pan Ceph elevates your extraoral imaging capabilities with perfected extraoral imaging.The 2D panoramic and cephalometric X- ray ...
... of patient on wheelchair, allowing easy access and demonstrating the concept of humanization. FeeLin integrated powerful system blessing to realize the interconnection of equipment, doctors, and patients ...
... Latest sensor and autofocus technology for the best image quality. Direct Conversion sensor Direct conversion of X- rays to electrical signals increases the image clarity and contrast while reducing the readout ...
Xline Imaging
... Films or phosphor plates solution One-sensor solution for any digital dental imaging ...
... for cm 15 x30 films Exposure time in panoramic modality: 15 sec. kV range from: 55 to 85 in steps of 5 kV Exposure time: in panoramic modality: 15 s Cephalometry: from 0.6 to 2.5 s Options: Cephalometry device with ...
... next-generation system competently executed, using unique advanced technology to respond to the extensive requirements of diagnostic imaging in dental therapy. This system has a wide CT image capture area and an accurate, ...
ASAHI Roentgen
... CT - Panoramic - Cephalometric - Intelligent anti-artifact technology provides a clearer and accurate digitisation and decreases chances of misdiagnosis; - Low-dose, intelligent noise reduction technology, ultimate image clarity - Intelligent ...
Bondent GmbH
Voxel size (μm3): 100, 127, 129 µm
... support precise diagnosis. Interworking with PACS and Digital Chart Easy interworking system is simplifying procedures, and all of patient treatment systems are automatically controlled with digital ...
PointNix
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group