Platelet laboratory incubator LPA-105
on casters1-doorUV

Platelet laboratory incubator - LPA-105 - Labotemp Systems - on casters / 1-door / UV
Platelet laboratory incubator - LPA-105 - Labotemp Systems - on casters / 1-door / UV
Add to favorites
Compare this product

Characteristics

Applications
for platelets
Configuration
on casters
Number of doors
1-door
Other characteristics
temperature-control, heating, cooling, with agitator, UV, automatic, on casters
Temperature range

Max.: 24 °C
(75.2 °F)

Min.: 20 °C
(68 °F)

Description

Product Overview
Labotemp Platelet Incubator with Agitator LPA-105 is a precision-controlled platelet incubator intended for the controlled storage and preservation of platelet concentrates in blood banks, hospital blood centers, transfusion services and clinical laboratories. The unit provides continuous horizontal agitation and accurate temperature regulation optimized for platelet viability.

Key Functions and Performance
The LPA-105 holds storage temperature at 22 ±2°C with a control accuracy of ±0.1°C. It delivers continuous left-right horizontal reciprocating agitation at 60 ±5 cycles/min with a 50 mm oscillation amplitude. Temperature is managed by digital signal detection and microprocessor control and displayed on an IPS high-definition touchscreen. Multiple temperature monitoring methods ensure reliable regulation.

Safety, Hygiene and Operation
Equipped with UV sterilization for chamber disinfection, automatic defrost, double-layer tempered glass door, anti-slip coated storage shelves and silent lockable casters for mobility. Audible and visual alarms monitor high/low temperature, abnormal shutdown, agitator malfunction, power failure and door-open status. Leakage protection and optional UPS backup improve operational safety and continuity.

Efficiency and Refrigeration
An air-cooled R134a refrigeration system provides stable, energy-efficient cooling. Heating consumption is 200 W and refrigeration consumption is 300 W. The unit is designed for continuous daily operation in clinical and blood bank environments.

Why Choose Labotemp Platelet Incubator with Agitator LPA-105?
  • Precision platelet storage: maintains 22 ±2°C with ±0.1°C accuracy and continuous horizontal agitation to support platelet viability.
  • Advanced safety monitoring: multi-level audible and visual alarms for temperature, agitator, power and door status.
  • Operational efficiency: UV sterilization, automatic defrost and energy-efficient R134a cooling reduce maintenance needs.

Features
  • Smart alarm system.
  • Microprocessor-controlled temperature regulation with IPS high-definition touchscreen.
  • Maintains 22 ±2°C storage temperature with ±0.1°C control accuracy.
  • Continuous horizontal reciprocating agitation at 60 ±5 cycles/min with 50 mm oscillation amplitude.
  • Multiple temperature monitoring methods for reliable control.
  • UV disinfection and chamber lighting for improved hygiene and sample visibility.
  • Audible and visual alarms for high/low temperature, abnormal shutdown, agitator malfunction and door-open status.
  • Air-cooled R134a refrigeration system for stable, energy-efficient cooling.
  • Automatic defrost to minimize maintenance.
  • Double-layer tempered glass door for thermal insulation.
  • Anti-slip coated storage shelves to secure platelet bags.
  • Quiet lockable casters for convenient movement.
  • Leakage protection for enhanced operational safety.
  • Optional: wireless monitoring, barcode scanner, UPS backup, LIS connectivity.

Applications
  • Controlled storage and preservation of platelet concentrates at 22 ±2°C.
  • Blood banks and transfusion medicine departments requiring continuous platelet agitation.
  • Hospital blood centers and clinical laboratories storing platelet products.
  • Hematology and pathology laboratories maintaining platelet viability prior to transfusion.
  • Blood component processing facilities needing monitored platelet preservation and traceability.
  • Healthcare environments complying with regulated platelet storage protocols.

Technical Specifications
  • Model: LPA-105
  • Temperature Control Method: Digital signal detection, microprocessor control
  • Temperature Range: 22 ±2°C
  • Temperature Accuracy: ±0.1°C
  • Ambient Temperature: 5–35°C
  • Alarm Temperature: <20°C, >24°C, abnormal shutdown & power failure alarm
  • Oscillation Frequency: 60 ±5 cycles/min
  • Oscillation Amplitude: 50 mm
  • Working Mode: Continuous left-right horizontal reciprocating agitation
  • Storage Capacity: 20 Blood Bags (Optimal), 40 Blood Bags (Maximum)
  • Heating Consumption: 200 W
  • Refrigeration Consumption: 300 W
  • Refrigerant: Air-cooled R134a
  • Power Supply: AC220V, 50/60Hz
  • Dimensions (W × D × H): 690 × 680 × 1050 mm
  • Shipping Dimensions (W × D × H): 820 × 800 × 1230 mm
  • Gross Weight: 90 kg
  • Display: IPS high-definition touchscreen
  • Disinfection: UV sterilization
  • Defrost: Automatic
  • Mobility: Silent lockable casters