Forced air laboratory incubator LPA-107
for plateletsfor hospitalsfor healthcare facilities

Forced air laboratory incubator - LPA-107 - Labotemp Systems - for platelets / for hospitals / for healthcare facilities
Forced air laboratory incubator - LPA-107 - Labotemp Systems - for platelets / for hospitals / for healthcare facilities
Add to favorites
Compare this product

Characteristics

Type
forced air
Applications
for hospitals, for healthcare facilities, for platelets, education
Configuration
on casters
Chamber material
stainless steel
Number of doors
1-door
Other characteristics
temperature-control, cooling, UV, with agitator
Temperature range

Max.: 24 °C
(75.2 °F)

Min.: 20 °C
(68 °F)

Description

Product description
Labotemp Platelet Incubator with Agitator LPA-107 provides controlled storage for platelet concentrates at 20–24°C with ±0.1°C accuracy. The unit integrates a programmable platelet agitator with 10 oscillating trays to hold up to 20 blood bags (450 mL). Forced-air, frost-free cooling and uniform chamber circulation preserve platelet quality for transfusion and laboratory use.

Design & operation
Built for continuous clinical operation, the LPA-107 features a stainless steel chamber and SPCC powder-coated exterior for easy cleaning and corrosion resistance. Operation is managed by a microprocessor controller with digital display, integrated UV light, built-in thermal printer for record-keeping, and a 72-hour power-failure backup. Safety functions include high/low temperature alarms, power-failure alarm, sensor-fault alarm, door-ajar alarm and a lockable door to protect platelet inventories.

Key features
  • Temperature accuracy: ±0.1°C
  • Frost-free forced-air cooling
  • Microprocessor-based temperature controller with digital display
  • Integrated oscillation system: 60 ± 5 cycles/min, 50 ± 10 mm amplitude
  • Capacity: 20 blood bags (450 mL) on 10 oscillating trays
  • Built-in thermal printer for temperature documentation
  • Built-in UV light for hygienic storage
  • Alarms: high/low temperature, power failure, sensor error, door ajar
  • 72-hour power-failure backup
  • Stainless steel interior; SPCC powder-coated exterior; universal caster wheels

Applications
  • Blood banks: Controlled temperature storage with continuous agitation to preserve platelet concentrates prior to transfusion
  • Hospitals & transfusion centers: Reliable storage for routine transfusion services and emergency platelet supply
  • Clinical & diagnostic laboratories: Stable storage conditions for platelet products used in testing and diagnostics
  • Biomedical research institutes: Standardized storage for hematology and transfusion research
  • Medical universities & training centers: Educational and research use for platelet preservation techniques
  • Quality-control & regulated facilities: Traceable storage with alarms, thermal printing and power-failure backup for compliance

Specifications
Performance & Temperature
Cooling method: Forced-air cooling
Defrost: Frost-free
Power-failure backup: 72 h
Temperature range: 20–24°C
Ambient range: 10–32°C
Noise level: 50 dB
Controller: Microprocessor
Sensor: NTC
Display: Digital display

Storage capacity & safety
Blood bag capacity: 20 blood bags (450 mL) / 10 trays
Thermal printer: Yes
Oscillation amplitude: 50 ± 10 mm
Oscillation frequency: 60 ± 5 cycles/min
Refrigerant: R134a
Exterior: SPCC sprayed steel
Interior: Stainless steel

Electrical & physical
Power supply: AC 220 V, 50/60 Hz or AC 110 V, 60 Hz
Power consumption: 280 W
Current: 1.27 A
Energy consumption: 4.4 kWh/24 h
Internal dims (W×D×H): 432 × 462 × 728 mm
External dims (W×D×H): 520 × 340 × 1290 mm
Net weight: 85 kg; Gross weight: 120 kg; Package size: 605 × 720 × 1480 mm

Technical specifications
  • Model: LPA-107
  • Temperature control range: 20–24°C
  • Temperature accuracy: ±0.1°C
  • Controller: Microprocessor
  • Sensor type: NTC
  • Display: Digital
  • Cooling method: Forced-air (frost-free)
  • Oscillation frequency: 60 ± 5 cycles/min
  • Oscillation amplitude: 50 ± 10 mm
  • Blood bag capacity: 20 bags (450 mL), 10 trays
  • Thermal printer: integrated
  • UV sterilization: built-in
  • Alarms: high/low temperature, power failure, sensor fault, door ajar
  • Power-failure backup: 72 hours
  • Refrigerant: R134a
  • Exterior: SPCC sprayed steel; Interior: Stainless steel
  • Power supply: AC 220 V 50/60 Hz or AC 110 V 60 Hz
  • Power consumption: 280 W; Current: 1.27 A; Energy: 4.4 kWh/24 h
  • Internal dims (W×D×H): 432 × 462 × 728 mm; External dims (W×D×H): 520 × 340 × 1290 mm
  • Net weight: 85 kg; Gross weight: 120 kg; Package size: 605 × 720 × 1480 mm
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.