Characteristics

Type
forced convection
Configuration
benchtop, stackable
Chamber material
stainless steel
Number of doors
1-door
Other characteristics
heating, with decontamination system
Temperature range

100 °C
(212 °F)

Capacity

59 l
(15.6 gal)

Description

Product description
The BINDER BF Avantgarde.Line laboratory incubator with forced convection is designed for controlled-temperature incubation of sensitive samples, especially under full load and high batch throughput. The unit provides highly homogeneous temperature distribution and short recovery times.

Benefits
  • Excellent temporal and spatial temperature accuracy
  • High process reliability and integrated safety device (Class 3.1, DIN 12880)
  • 100 °C disinfection routine


Important characteristics
  • Temperature range: +7 °C above ambient to +100 °C
  • APT.line™ technology for high temperature accuracy
  • Forced convection (adjustable fan)
  • Controller with LCD display and USB data port
  • Electromechanical control of exhaust air flap
  • Inner door made of tempered safety glass
  • 2 chrome-plated racks (std.), stackable (max. 4)


Technical specifications — Data
Article Number: 9010-0313 / 9010-0314
Designation: BF056-230V / BF056UL-120V
Option model: Standard

Technical specifications — Performance Data Temperature
Temperature range: +7 °C above ambient to 100 °C
Temperature uniformity at 37 °C: 0.2 ± K
Temperature uniformity at 100 °C: 1.0 ± K
Temperature fluctuation at 37 °C: 0.1 ± K
Temperature fluctuation at 100 °C: 0.2 ± K
Heating up time to 100 °C: 35 min
Heating up time to 37 °C: 6 min
Recovery time after door opened 30 s at 37 °C: 3 min

Technical specifications — Electrical data
Rated Voltage: 230 V (9010-0313) / 120 V (9010-0314)
Power frequency: 50/60 Hz (230 V) / 60 Hz (120 V)
Nominal power: 0.4 kW
Unit fuse: 6.3 A (230 V) / 12.5 A (120 V)
Phase (Nominal voltage): 1~

Technical specifications — Dimensions and weights
Interior volume: 59 L
Net weight (empty): 39 kg
Load per rack: 30 kg
Permitted load: 70 kg
Wall clearance back: 160 mm
Wall clearance sidewise: 100 mm

Technical specifications — Housing / Internal Dimensions
Width net: 560 mm
Height net: 625 mm
Depth net: 565 mm
Interior width: 400 mm
Interior height: 440 mm
Interior depth: 340 mm
Inner doors: 1
Unit doors: 1

Technical specifications — Environment-specific data
Sound-pressure level: 43 dB(A)
Energy consumption at 100 °C: 190 Wh/h
Energy consumption at 37 °C: 55 Wh/h

Technical specifications — Fixtures
Number of shelves (std./max.): 2/4

Options, accessories & services (selected examples)
  • Inert gas connection (gas inlet/outlet, Ø 10 mm)
  • Gas-tight option model (increased impermeability)
  • Access port with silicone plug (various diameters/positions)
  • Calibration certificates (temperature, various scopes)
  • Ethernet interface for APT-COM™
  • Pt 100 additional interior sensor
  • Analog output 4-20 mA (temperature)
  • Acoustic overheating alarm
  • Door lock (lockable handle)
  • Maintenance/service contracts (BRONZE / SILVER / GOLD), calibration and qualification services (IQ/OQ/PQ)
  • Accessories: chrome or stainless steel racks, perforated shelves, mobile table, APT-COM™ software, detergent


Technical summary / specifications
  • Model: BF 56 (Avantgarde.Line)
  • Temperature range: +7 °C above ambient to +100 °C
  • APT.line™ technology for high temperature accuracy
  • Forced convection, adjustable fan
  • Controller: LCD display, USB data export
  • Independent temperature safety device: Class 3.1 (DIN 12880) with visual alarm
  • Interior volume: 59 L; Net dimensions (W×H×D): 560 × 625 × 565 mm
  • Interior dimensions (W×H×D): 400 × 440 × 340 mm; Net weight: 39 kg
  • Standard shelves: 2 (max. 4); max. load per rack: 30 kg; permitted total load: 70 kg
  • Rated voltage/options: 230 V (9010-0313) or 120 V (9010-0314); Nominal power: 0.4 kW
  • Sound-pressure level: 43 dB(A); Energy consumption: 55 Wh/h (37 °C) / 190 Wh/h (100 °C)

VIDEO

Catalogs

No catalogs are available for this product.

See all of BINDER GmbH‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Oslo Battery Days
Oslo Battery Days

24-25 Aug 2026 Oslo (Norway)

  • More information
    Lab-Supply Dresden
    Lab-Supply Dresden

    8-08 Sep 2026 Dresden (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.