Product IntroductionThe Ion Chromatograph BK-IC260D is a compact dual-channel system for simultaneous detection of anions and cations. It integrates an intelligent alarm suite (leak, residual eluent, low/high pressure) and real-time consumables monitoring to maintain clear operational status while optimising laboratory bench space.
Product Details- Brand: BIOBASE
- Product origin: CHINA
- Delivery time: Within 7 days
- Supply capacity: Factory direct supply
- Model: BK-IC260D
Features- Dual-channel architecture for concurrent anion and cation analysis.
- Intelligent alarm system: leakage, residual eluent, low-pressure and high-pressure alerts.
- Real-time monitoring of consumables for quick status checks.
- Compact exterior design to improve laboratory space utilisation.
Technical ParametersModel: BK-IC260D
Detected ions: Anions and cations
Pump - Type: High-pressure, low-pulse two-piston tandem advection pump
Pump - Maximum pressure: 42 MPa
Pump - Flow rate range: 0.001–12 mL/min
Pump - Pressure ripple: ≤0.5%
Flow precision: ≤0.1%
Column oven - Operating temperature range: RT+5~85℃
Column oven - Temperature control accuracy: ±0.1℃
Column oven - Temperature stability: ≤0.1℃/h
Columns supported: 2, 3, 4 and 5 mm ID; max analytical column length 250 mm with 50 mm guard column
Conductivity detector - Type: Auto-range conductivity detector
Conductivity detector - Cell volume: ≤0.4 μL
Conductivity detector - Detection range: 0–50000 μS/cm
Conductivity detector - Resolution: ≤0.0020 nS/cm
Conductivity detector - Operating temperature range: RT+5℃~60℃
Conductivity detector - Maximum pressure: 10.0 MPa
Suppressor - Type: Self-regenerating electrolytic micromembrane suppressor
Suppressor - Maximum pressure: 6.0 MPa
Non-suppressed chromatography: Yes
Void volume: <40 μL (4 mm); <15 μL (2 mm)
Optional accessories: BK-CIC3200 fully automatic combustion system; SHA-18i autosampler (dual-channel, 120 sample positions)
Power supply: AC100~220V 50/60Hz
External size (W×D×H): 422×500×641 mm
Net weight: 42 kg
Packing size (W×D×H): 670×570×790 mm; 660×620×400 mm
Gross weight: 60 kg; 10 kg
Specifications- Model: BK-IC260D
- Detected ions: Anions and cations (dual-channel)
- Pump: Two-piston tandem advection pump; max pressure 42 MPa; flow 0.001–12 mL/min; pressure ripple ≤0.5%; flow precision ≤0.1%
- Column oven: RT+5~85℃; accuracy ±0.1℃; stability ≤0.1℃/h; supports 2/3/4/5 mm ID columns, max analytical length 250 mm (with 50 mm guard)
- Conductivity detector: Auto-range; detection 0–50000 μS/cm; cell vol ≤0.4 μL; resolution ≤0.0020 nS/cm; max pressure 10.0 MPa
- Suppressor: Self-regenerating electrolytic micromembrane; max pressure 6.0 MPa; supports non-suppressed chromatography
- Dimensions: 422×500×641 mm; Net weight 42 kg; Power AC100–220V 50/60Hz