Product overviewFixed recirculating fume cupboards from Envair Technology are designed for classrooms and preparation rooms where installing ductwork is problematic (for example listed buildings). The unit recirculates air back into the laboratory via an integral fan unit and an integral carbon filter rather than exhausting to atmosphere. The carbon filter is suitable for the standard chemicals used in GCSE and A Level curriculum work.
Maintenance and complianceAnnual maintenance service is available which includes carbon filter saturation testing and replacement supply and installation of filters as required by COSHH regulations. In a preparation-room environment, carbon filter replacement will typically be more frequent due to higher usage and exposure to concentrated chemicals over time. All Envair Technology educational fume cupboards are designed in accordance with CLEAPSS Guide G9 – Fume Cupboards in Schools and are independently tested and passed by CLEAPSS.
Key features- Glazed side panels for demonstrations
- Fixed in position with levelling feet
- Integral 25kg carbon filter
- Protective pre-filter
- No fumes to atmosphere (ductless operation)
- Integral high-level lighting
- Trespa Toplab work surface
- Airflow control panel
- RCD protected double socket outlet
- Vertically sliding toughened glass sash
- Remote-operated gas and water outlets
- Dimensions: 1000mm wide x 715mm deep x 2070mm high (also available in 1200mm and 1500mm widths)
- Nominal air flow: 0.4 m/s face velocity at a 400mm opening
- Voltage: 240V / 1 ph / 50Hz
caractéristiques / spécifications techniques- Model type: Fixed recirculating (ductless) fume cupboard
- Carbon filter: integral, 25 kg (with protective pre-filter)
- Face velocity: nominal 0.4 m/s at 400 mm sash opening
- Typical dimensions: 1000 mm (W) x 715 mm (D) x 2070 mm (H); alternative widths: 1200 mm and 1500 mm
- Work surface: Trespa Toplab
- Sash: vertically sliding toughened glass
- Side panels: glazed for demonstration visibility
- Lighting: integral high-level lighting
- Electrical: RCD-protected double socket; 240 V / single phase / 50 Hz
- Controls: airflow control panel
- Utilities: remote-operated gas and water outlets
- Installation: fixed in position with levelling feet
- Compliance: designed to CLEAPSS Guide G9 and independently tested/passed by CLEAPSS
- Maintenance: annual service including carbon filter saturation testing and replacement as required by COSHH; replacement frequency depends on usage and exposure levels