Cooling laboratory incubator KT 115
forced convectionthermoelectricfor scientific research

Cooling laboratory incubator - KT 115 - BINDER GmbH - forced convection / thermoelectric / for scientific research
Cooling laboratory incubator - KT 115 - BINDER GmbH - forced convection / thermoelectric / for scientific research
Cooling laboratory incubator - KT 115 - BINDER GmbH - forced convection / thermoelectric / for scientific research - image - 2
Cooling laboratory incubator - KT 115 - BINDER GmbH - forced convection / thermoelectric / for scientific research - image - 3
Add to favorites
Compare this product

Characteristics

Type
forced convection, thermoelectric
Applications
for the pharmaceutical industry, for microbiology, for scientific research, for the food industry
Configuration
stackable
Chamber material
stainless steel
Number of doors
1-door
Other characteristics
temperature-control, heating, cooling, with decontamination system, Peltier effect
Temperature range

Max.: 100 °C
(212 °F)

Min.: 4 °C
(39.2 °F)

Capacity

102 l
(26.9 gal)

Description

Product description
The KT 115 cooled incubator provides controlled incubation and temperature management for laboratory samples. Cooling is delivered via an electric Peltier module while hot-air disinfection at 100 °C supports hygiene routines. The unit is designed for reproducible conditions and data recording in professional lab environments.

Benefits
  • Maintains safe, reproducible incubation conditions even at elevated ambient temperatures
  • Hot-air disinfection at 100 °C for contamination control
  • Energy-efficient operation with integrated data interfaces


Important characteristics
  • Temperature range: +4 °C to +100 °C
  • APT.line™ preheating chamber technology
  • Adjustable fan speed
  • Electric cooling with Peltier module
  • Controller with time-segment and real-time programming
  • Display via LCD monitor; input via pushbutton/rotary knob
  • Inner door made of tempered safety glass
  • 2 stainless steel racks (standard), stackable
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible alarm
  • Computer interface: Ethernet; data recording and USB interface


Technical specifications — Data
Article Number: 9020-0313 | 9020-0314
Designation: KT115-230V | KT115UL-120V
Option model: Standard

Performance Data Temperature
Article Number: 9020-0313 | 9020-0314
Temperature range: 4...100 °C
Temperature uniformity at 37 °C: 0.3 ± K
Temperature fluctuation at 37 °C: 0.1 ± K
Max. heat compensation at 40 °C: 100 W
Recovery time after door opened 30 s at 37 °C: 3 min

Electrical data
Article Number: 9020-0313 | 9020-0314
Rated voltage: 200...240 V (9020-0313) | 100...120 V (9020-0314)
Power frequency: 50/60 Hz
Nominal power: 0.7 kW
Unit fuse: 10,0 A
Phase (Nominal voltage): 1~

Dimensions and weights
Interior volume: 102 L
Net weight (empty): 83 kg
Load per rack: 30 kg
Permitted total load: 100 kg
Wall clearance back: 100 mm
Wall clearance sidewise: 240 mm

Housing dimensions (not incl. fittings and connections)
Width net: 860 mm
Height net: 715 mm
Depth net: 655 mm

Internal Dimensions
Interior width: 600 mm
Interior height: 455 mm
Interior depth: 355 mm
Inner doors: 1
Unit doors: 1

Environment-specific data
Sound-pressure level: 48 dB(A)
Energy consumption at 25 °C: 75 Wh/h
Energy consumption at 37 °C: 75 Wh/h

Fixtures
Number of shelves (std./max.): 2/6

Notes
Controller features: time-segment and real-time programming; display via LCD; input via pushbutton/rotary knob. Cooling is provided electrically using a Peltier module. Hot-air disinfection available at 100 °C.

Characteristics / technical specifications
  • Model: KT 115
  • Cooling technology: Peltier module (electric cooling)
  • Temperature range: 4 °C to 100 °C
  • Interior volume: 102 L
  • Temperature uniformity (37 °C): ±0.3 K
  • Temperature stability (37 °C): ±0.1 K
  • Recovery time after 30 s door opening (37 °C): 3 min
  • Interfaces: Ethernet, USB for data logging
  • Controller: time-segment and real-time programming, LCD display
  • Safety: independent temperature safety device class 3.1 (DIN 12880) with visual and audible alarm
  • Construction: tempered inner door, 2 stainless steel racks (std.), stackable
  • External dimensions (W × H × D): 860 × 715 × 655 mm
  • Internal dimensions (W × H × D): 600 × 455 × 355 mm
  • Net weight: 83 kg
  • Rated power: 0.7 kW; energy consumption in use: 75 Wh/h
  • Sound level: 48 dB(A)
  • Shelves (std/max): 2 / 6

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Lab-Supply Dresden
Lab-Supply Dresden

8-08 Sep 2026 Dresden (Germany)

  • More information
    Lab-Supply Hamburg
    Lab-Supply Hamburg

    3-03 Nov 2026 Hamburg (Germany)

  • More information

    Other BINDER GmbH products

    Cooling incubators