Ultrasound imaging test phantom Simple Head
for CT scanfor MRIbrain

Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 2
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 3
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 4
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 5
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 6
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 7
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 8
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 9
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 10
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 11
Ultrasound imaging test phantom - Simple Head - True Phantom Solutions - for CT scan / for MRI / brain - image - 12
Add to favorites
Compare this product

fo_shop_gate_exact_title

Characteristics

Type of calibration
for ultrasound imaging, for CT scan, for MRI
Area of the body
brain

Description

The Newborn Head (Simple) phantom is designed based on an average newborn head and is made out of realistic tissue-mimicking materials suitable for X-Ray CT, US, MRI. - The phantom is designed based on an average newborn head and is made out of realistic tissue-mimicking materials suitable for Ultrasound imaging. The brain in this model has been specifically simplified to achieve the most cost-efficient training solution. This phantom can be used with Barium-sulfate, Iodine-based, and Microbubble contrast mediums. - The phantom was developed in collaboration with a group of physician experts from the Sonographic Clinical Assessment of the Newborn (SCAN) Training Program at the University of Calgary (Department of Pediatrics). Anatomy: - Newborn Brain - Corpus Callosum - Brain Ventricles Note: By default, the phantom comes in a translucent amber appearance. The skin feature can be included upon request. Included in Order: - Newborn Head (Simple) Phantom - User Manual/Assembly Instructions - 2-Year Warranty & Unlimited Customer Service - Hard Carry Case Size & Weight: - Phantom: - Size: 5 x 6 x 5 Inches - Weight: 4 Lbs (approx.) - Shipment: - Size: 12 x 10 x 10 Inches - Weight: 6 Lbs (approx.) Materials Used: - Soft tissue and organs: Composition of urethane-based soft resin - Synthetic bones: Patented ceramic-reinforced epoxy-based composite material Technical Properties: Type of Tissue | Sound Velocity [m/s] | Density [g/cm³] | Hardness [Shore 00] | T2 [ms] | Speckles | Attenuation Measured at 2.25 MHz [dB/cm] - Brain Matter: 1400 ± 10 | 0.99 | 20 | 70 | YES | 1.0 ± 0.2 - Soft Tissue: 1400 ± 10 | 1.01 | 35 | N/A | NO | 1.3 ± 0.2 HU Values of the Tissue-Mimicking Materials: S.No. | Tissue Type | HU Value (average) 1 | Brain Tissue | -25 Newborn Head Model: Complex Head, Simple Head, Dynamic Head FAQ: Please refer to the FAQ page for more information. Characteristics / Technical Specifications: - Model: Simple Head (also available: Complex Head, Dynamic Head) - SKU: HD-N02 - Phantom Size: 5 x 6 x 5 Inches - Phantom Weight: 4 Lbs (approx.) - Shipment Size: 12 x 10 x 10 Inches - Shipment Weight: 6 Lbs (approx.) - Soft tissue and organs: Urethane-based soft resin - Synthetic bones: Ceramic-reinforced epoxy-based composite - Brain Matter: Sound Velocity 1400 ± 10 m/s, Density 0.99 g/cm³, Hardness 20 Shore 00, T2 70 ms, Speckles: YES, Attenuation at 2.25 MHz: 1.0 ± 0.2 dB/cm - Soft Tissue: Sound Velocity 1400 ± 10 m/s, Density 1.01 g/cm³, Hardness 35 Shore 00, T2 N/A, Speckles: NO, Attenuation at 2.25 MHz: 1.3 ± 0.2 dB/cm - HU Value (Brain Tissue): -25 - Default appearance: Translucent amber (skin feature optional) - Compatible with Barium-sulfate, Iodine-based, and Microbubble contrast mediums - Developed with University of Calgary (SCAN Program)

Catalogs

No catalogs are available for this product.

See all of True Phantom Solutions‘s catalogs

Other True Phantom Solutions products

X-Ray CT, MRI, US

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.