Laboratory centrifuge BKC-TH16C
clinicalfor researchfor sample preparation

Laboratory centrifuge - BKC-TH16C - Biobase - clinical / for research / for sample preparation
Laboratory centrifuge - BKC-TH16C - Biobase - clinical / for research / for sample preparation
Laboratory centrifuge - BKC-TH16C - Biobase - clinical / for research / for sample preparation - image - 2
Add to favorites
Compare this product

Characteristics

Applications
laboratory, for research, clinical
Function
for sample preparation, for blood phase separation
Sample type
blood
Configuration
benchtop
Rotor type
swing-out, fixed-angle
Performance
high-speed
Glassware
for microtubes
Operation
automatic
Other characteristics
with touch screen control
Speed

Max.: 16,000 rpm
(100,531 rad.min-1)

Min.: 0 rpm
(0 rad.min-1)

RCF max (g)

Max.: 21,695 unit

Min.: 50 unit

Noise level

Max.: 65 dB

Min.: 10 dB

Weight

29 kg
(63.9 lb)

Length

34 cm
(13.4 in)

Width

50 cm
(19.7 in)

Height

34 cm
(13.4 in)

Description

Introduction
The centrifuge uses centrifugal force from high-speed rotation to rapidly separate, concentrate and purify mixtures with different sedimentation coefficients. Intended for clinical and laboratory pre-analytical separation of human samples and for biomedical research applications.

Product information
  • Brand: BIOBASE
  • Origin: China
  • Lead time: Within 7 days
  • Supply capacity: Direct factory supply
  • Model: BKC-TH16C


Features
  • All-metal, multi-layer explosion-proof housing for safe laboratory operation.
  • Embedded microprocessor control with DC brushless motor for maintenance-free, stable operation.
  • 5-inch LCD touchscreen with multilingual support (Chinese/English; additional languages customizable).
  • Real-time display of parameters and an intuitive user interface.
  • Electromechanical integrated door lock for secure operation.
  • Integral food-grade silicone sealing ring to prevent aerosol leakage and protect the operator.
  • Self-test and alarm functions (block, overspeed, overtemperature) and effective shock absorption.
  • User-defined program groups and quick-access presets; boots to the last used program.
  • Wide range of angle and swing rotors (aviation forged aluminum) and adapters for tubes from 0.2 ml to 100 ml for multi-purpose use.
  • Optional automatic rotor recognition.


Technical Parameters
  • Model: BKC-TH16C
  • Max. speed: 16000 rpm
  • Speed accuracy: ±20 rpm
  • Max. RCF: 21695×g
  • Max. volume: 4 × 100 ml
  • Power supply: Standard AC220V 50/60Hz (Optional AC110V 50/60Hz)
  • Timing range: 1 s ~ 99 h 59 min, continuous/short-span
  • Noise: ≤65 dB
  • External size (L×W×H): 340 × 500 × 340 mm
  • Net weight: 29 kg
  • Gross weight: 37 kg (220V), 42 kg (110V)


Rotors
16M0003 | Angle rotor | 8×7 ml | Max. speed: 14000 rpm | Max. RCF: 16435×g | Adapters: /
16M0004 | Angle rotor | 12×10/15 ml (low speed) | Max. speed: 6000 rpm | Max. RCF: 3743×g | Adapters: 2/3/4/5/7 ml blood tubes; 5 ml/7 ml; 15 ml (▲)
16M0005 | Angle rotor | 12×10 ml (high speed) | Max. speed: 12000 rpm | Max. RCF: 14328×g | Adapters: 1.5/2 ml, 5 ml
16M0006 | Angle rotor | 12×1.5/2 ml | Max. speed: 16000 rpm | Max. RCF: 18031×g | Adapters: 0.2 ml, 0.5 ml
16M0007 | Angle rotor | 18×1.5/2 ml | Max. speed: 15000 rpm | Max. RCF: 18866×g | Adapters: 0.2 ml, 0.5 ml
16M0008 | Angle rotor | 24×1.5/2 ml | Max. speed: 14000 rpm | Max. RCF: 19722×g | Adapters: 0.2 ml, 0.5 ml
16M0090 | Angle rotor | 36×1.5/2 ml | Max. speed: 13000 rpm | Max. RCF: 19159×g | Adapters: 0.2 ml, 0.5 ml
16M0091 | Angle rotor | 48×1.5/2 ml | Max. speed: 13000 rpm | Max. RCF: 19159×g | Adapters: 0.2 ml, 0.5 ml
16M0085 | Angle rotor | 40×0.2 ml | Max. speed: 16000 rpm | Max. RCF: 21695×g | Adapters: /
16M0086 | Angle rotor | 24×0.5 ml | Max. speed: 16000 rpm | Max. RCF: 20035×g | Adapters: /
16M0087 | Angle rotor | 30×0.5 ml | Max. speed: 13000 rpm | Max. RCF: 15210×g | Adapters: /
16M0088 | Angle rotor | 40×0.5 ml | Max. speed: 13000 rpm | Max. RCF: 15267×g | Adapters: /
16M0089 | Angle rotor | 4×8×0.2 ml PCR | Max. speed: 13000 rpm | Max. RCF: 11941×g | Adapters: /
16M0009 | Angle rotor | 10×5 ml | Max. speed: 14000 rpm | Max. RCF: 15339×g | Adapters: 1.5/2 ml
16M00010 | Angle rotor | 8×15 ml (▲) | Max. speed: 12000 rpm | Max. RCF: 15294×g | Adapters: 5 ml (▲)
16M00011 | Angle rotor | 8×15 ml (●) | Max. speed: 12000 rpm | Max. RCF: 15294×g | Adapters: /
16M0017 | Angle rotor | 10×15 ml | Max. speed: 11000 rpm | Max. RCF: 13798×g | Adapters: /
16M00012 | Angle rotor | 6×50 ml (▲) | Max. speed: 11000 rpm | Max. RCF: 13798×g | Adapters: 15 ml (▲), 50 ml (●)
16M00013 | Angle rotor | 6×50 ml (round/flat) | Max. speed: 11000 rpm | Max. RCF: see spec | Adapters: /
16M0062-1 | Swing rotor | 8×10 ml | Max. speed: 4000 rpm | Max. RCF: 2522×g | Adapters: 2/3/4 ml blood tubes; 5/7/10 ml (▲)
16M0020 | Swing rotor | 24 capillaries | Max. speed: 12000 rpm | Max. RCF: 14170×g | Adapters: /
16M0066 | Swing rotor | 4×100 ml | Max. speed: 4000 rpm | Max. RCF: 2379×g | Adapters: 2/3/4 ml; 5/7 ml

Note
Mark (●) indicates round-bottom tube; mark (▲) indicates sharp-bottom tube.

Exhibitions

Meet this supplier at the following exhibition(s):

ADLM
ADLM

28-30 Jul 2026 Anaheim (USA - California) Stand 947

  • More information
    Arablab
    Arablab

    26-28 Oct 2026 Dubai (United Arab Emirates)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.