Product overview
T3LPF is an electro-pneumatic instrument for air flow testing at programmed pressure and for leak testing using absolute pressure decay measurement. Its pneumatic circuit supports both direct mass flow measurement and pressure-decay leak testing, making it suitable for test benches, production lines and automated systems.

Description
The instrument integrates a mass flow sensor and an electronic pressure regulator. A 7\" full-colour touchscreen displays real-time graphical and numeric test results, simplifying programming and operation. Configurable pneumatic fixtures and external automation control adapt the unit to specific test setups.

Performance
T3LPF offers high-resolution acquisition and versatile ranges for industrial applications. Measurement speed and resolution enable precise characterization of flow and leak behaviour during inline or standalone tests.

Connectivity
T3LPF provides Digital I/O for PLCs, USB host, RS485/RS232 serial ports and Ethernet (LAN/Profinet). It can control external devices such as printers, barcode/QR readers and remote keypads. Dedicated software manages test sequences, data collection and SPC analysis.

Benefits
  • Flow measurement with mass sensor — full scales from 50 cm3/min to 300 l/min
  • Flow resolution up to 0.01 cm3/min
  • Leak test by absolute pressure decay — full scale up to 6 bar
  • Leak resolution up to 0.1 Pa
  • 7\" full-colour LCD with graphical test view
  • Interfaces: Digital I/O (PLC), USB host, RS485/RS232, Ethernet (LAN/Profinet)
  • Data storage on USB pen drive or network (LAN/Ethernet/Profinet)
  • Control of external automations and devices: printers, barcode/QR readers, remote keypad, air filters
  • Dedicated Software Manager for module management, data storage and SPC

Technical specifications
  • Model: T3LPF
  • Measurement methods: mass flow sensor (direct flow) and absolute pressure decay (leak)
  • Flow full-scale ranges: 50 cm3/min to 300 l/min
  • Flow resolution: up to 0.01 cm3/min
  • Leak full-scale (pressure decay): up to 6 bar
  • Leak resolution: up to 0.1 Pa
  • Display: 7\" full-colour LCD, graphical test view
  • Interfaces: Digital I/O (PLC), USB host, RS485/RS232, Ethernet (LAN/Profinet)
  • Data storage: USB pen drive, LAN/Ethernet/Profinet
  • External device control: printers, barcode/QR readers, remote keypad, air filters
  • Software: dedicated manager for data collection, parameter programming and SPC
  • Applications: test benches, production lines, fully automated systems