Product overviewLabotemp LLC-502 is a refrigerated biosafety centrifuge engineered for secure, temperature-controlled processing of clinical and research specimens in hospitals, blood banks and bioprocess laboratories. The unit supports a maximum speed of 6000 rpm (up to 4588 × g) and a maximum capacity of 4×1000 ml, enabling high-throughput blood component separation and large-volume sample preparation. Key biosafety measures include a gas‑tight rotor with aerosol containment, an integrated UV sterilization chamber and high-temperature sterilizable components. The microprocessor-controlled system provides precise speed and time control with selectable acceleration/deceleration profiles. Noise level is ≤58 dB(A) and the robust stainless steel chamber and safety interlocks are designed for continuous professional use.
Why choose LLC-502?- Secure containment: gas-tight rotor with aerosol protection and UV sterilization
- High throughput: supports up to 4×1000 ml for large-volume processing
- Precision control: microprocessor regulation with adjustable acceleration/deceleration and temperature control
Features- Maximum capacity 4×1000 ml for bulk sample runs
- Speed up to 6000 rpm with RCF up to 4588 × g
- Temperature control range −20°C to +40°C with ±1°C accuracy
- Intuitive control panel for program storage and monitoring
- Gas-tight rotor design and aerosol containment for infectious samples
- UV sterilization chamber and components compatible with high-temperature sterilization
- Imbalance detection, lid interlock and automatic shutdown for operator safety
- Low noise operation (≤58 dB(A)) and durable stainless steel chamber
- Microprocessor-controlled acceleration/deceleration (1–10 levels) for gentle sample handling
Applications- Temperature-controlled separation of blood components and plasma in hospitals and blood banks
- Processing infectious or sensitive biological samples under containment conditions
- Protein purification, cell harvesting and pharmaceutical sample preparation in regulated labs
Rotor configurations- 1 — Angle rotor: 12 × 5–10–15 ml — Max speed: 6000 rpm — Max RCF: 4588 × g
- 2 — Swing-bucket: 4 × 600 ml — Max speed: 4000 rpm — Max RCF: 3354 × g
- Adapters: 4 × 25 × 2–5 ml; 4 × 12 × 10–15 ml; 4 × 5 × 50 ml; 4 × 4 × 100 ml
- 3 — Swing-bucket: 4 × 800 ml — Max speed: 4000 rpm — Max RCF: 3443 × g
- Adapters: 4 × 30 × 2–5 ml; 4 × 16 × 10–15 ml; 4 × 6 × 50 ml; 4 × 4 × 100 ml
- 4 — Swing-bucket: 6 × 600 ml — Max speed: 4000 rpm — Max RCF: 3400 × g
- Adapters: 6 × 25 × 2–5 ml; 6 × 12 × 10–15 ml; 6 × 5 × 50 ml; 6 × 4 × 100 ml
- 5 — Swing-bucket: 4 × 1000 ml — Max speed: 4000 rpm — Max RCF: 3578 × g
- Adapters: 4 × 42 × 2–5 ml; 4 × 23 × 10–15 ml; 4 × 7 × 50 ml; 4 × 4 × 100 ml
- 6 — Swing-bucket: 4 × 750 ml — Max speed: 4000 rpm — Max RCF: 3443 × g
- Adapters: 4 × 28 × 2–5 ml; 4 × 15 × 10–15 ml; 4 × 5 × 50 ml; 4 × 3 × 100 ml
Technical specifications- Maximum capacity: 4 × 1000 ml
- Maximum speed: 6000 rpm
- Speed range: 0–6000 rpm; accuracy ±10 rpm
- Maximum RCF: 4588 × g; RCF range 0–4588 × g
- Time range: 1–99 minutes
- Acceleration/deceleration: 1–10 selectable levels
- Noise level: ≤58 dB(A)
- Temperature control range: −20°C to +40°C; accuracy ±1°C
- Power supply: AC 220V, 50 Hz, 15 A, 1800 W
- Dimensions (L × W × H): 810 × 670 × 890 mm
- Net weight (without rotor): 200 kg
- Safety features: gas-tight rotor with aerosol containment, UV sterilization chamber, high-temperature sterilizable components, lid interlock, imbalance detection, automatic shutdown
- Construction: stainless steel chamber, microprocessor control, user-friendly control panel