OverviewLabotemp Biosafety Centrifuge LLC-502 is a high-performance clinical/refrigerated biosafety centrifuge designed for secure, temperature-controlled processing of biological samples in hospitals, blood banks and research laboratories. Engineered for biosafety and sample integrity, it features sealed/gas-tight rotor design with aerosol containment, UV sterilization chamber and high-temperature sterilizable components, plus microprocessor control for smooth acceleration/deceleration and advanced safety interlocks.
Key Benefits- High biosafety protection: sealed rotor with aerosol containment and UV sterilization chamber
- Large capacity: Up to 4 × 1000 ml for high-throughput labs
- Reliable performance: Microprocessor control with imbalance detection, lid interlock and automatic shutdown
- Temperature control: Preserves sample integrity during runs
- Low noise operation for improved lab comfort
Features- High capacity 4×1000 ml
- Supports large-volume sample processing with stable performance across extended operational cycles
- Intuitive control panel for parameter setting and monitoring
- Heavy-duty construction for intensive laboratory workloads
- Optimized rotor balance for uniform separation
- Smooth start/stop control for improved sample handling
- Integrated mobility design for repositioning within labs
- Flexible workflow management with adjustable operational parameters (acceleration/deceleration rates)
Applications- Temperature-controlled separation of blood components, plasma and biological samples in hospitals and blood banks
- Handling sensitive or infectious samples requiring containment
- Protein isolation, cell harvesting and pharmaceutical sample preparation under regulated conditions
Optional Modules / Rotors (table)No. | Item | Max. Capacity | Max. Speed | Max. RCF
1 | Angle Rotor | 12 × 5–10–15 ml | 6000 r/min | 4588 × g
— | Adapter | 12 × 2 ml | — | —
2 | Swing Bucket | 4 × 600 ml | 4000 r/min | 3354 × g
— | Adapter | 4 × 25 × 2–5 ml | — | —
— | Adapter | 4 × 12 × 10–15 ml | — | —
— | Adapter | 4 × 5 × 50 ml | — | —
— | Adapter | 4 × 4 × 100 ml | — | —
3 | Swing Bucket | 4 × 800 ml | 4000 r/min | 3443 × g
— | Adapter | 4 × 30 × 2–5 ml | — | —
— | Adapter | 4 × 16 × 10–15 ml | — | —
— | Adapter | 4 × 6 × 50 ml | — | —
— | Adapter | 4 × 4 × 100 ml | — | —
4 | Swing Bucket | 6 × 600 ml | 4000 r/min | 3400 × g
— | Adapter | 6 × 25 × 2–5 ml | — | —
— | Adapter | 6 × 12 × 10–15 ml | — | —
— | Adapter | 6 × 5 × 50 ml | — | —
— | Adapter | 6 × 4 × 100 ml | — | —
5 | Swing Bucket | 4 × 1000 ml | 4000 r/min | 3578 × g
— | Adapter | 4 × 42 × 2–5 ml | — | —
— | Adapter | 4 × 23 × 10–15 ml | — | —
— | Adapter | 4 × 7 × 50 ml | — | —
— | Adapter | 4 × 4 × 100 ml | — | —
6 | Swing Bucket | 4 × 750 ml | 4000 r/min | 3443 × g
— | Adapter | 4 × 28 × 2–5 ml | — | —
— | Adapter | 4 × 15 × 10–15 ml | — | —
— | Adapter | 4 × 5 × 50 ml | — | —
— | Adapter | 4 × 3 × 100 ml | — | —
Notes / Additional detailsMaximum speed is specified as 6000 rpm (page mentions 6000 rpm and also references 6080×g in descriptive text), while the specification table lists maximum RCF as 4588 × g. The unit uses a durable stainless steel chamber and is designed for continuous laboratory use with noise level ≤ 58 dB(A).
Caractéristiques / spécifications techniques- Maximum Speed: 6000 rpm (page text also references 6080×g)
- Maximum RCF: 4588 × g
- Power Supply: AC 220V, 50Hz, 15A, 1800W
- Maximum Capacity: 4 × 1000 ml
- Speed Range: 0 – 6000 rpm
- Speed Accuracy: ±10 r/min
- RCF Range: 0 – 4588 × g
- Time Range: 1 – 99 minutes
- Acceleration / Deceleration: 1 – 10 rates
- Temperature Control Range: -20°C to +40°C
- Temperature Control Accuracy: ±1°C
- Noise Level: ≤ 58 dB(A)
- Dimensions (L × W × H): 810 × 670 × 890 mm
- Net Weight (without rotor): 200 kg
- Safety & biosafety features: lid interlock, imbalance detection, gas-tight rotor with aerosol containment, UV sterilization chamber, high-temperature sterilizable components