Automated immunoassay analyzer BKI2200
for clinical diagnosticchemiluminescencechemiluminescence immunoassay

Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay - image - 2
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay - image - 3
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay - image - 4
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay - image - 5
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay - image - 6
Automated immunoassay analyzer - BKI2200 - Biobase - for clinical diagnostic / chemiluminescence / chemiluminescence immunoassay - image - 7
Add to favorites
Compare this product

Characteristics

Operation
automated
Applications
for clinical diagnostic
Analysis mode
chemiluminescence, chemiluminescence immunoassay, enzymatic chemiluminescence
Sample type
serum, plasma
Configuration
compact, integrated system
Other characteristics
with touch screen, with LIS connectivity, with barcode reader
Throughput

240 p/h

Description

Introduction
The BKI2200 chemiluminescence immunoassay system uses magnetic particle separation with magnetic particles as antibody carriers to ensure uniform distribution in liquid-phase reactions, delivering faster reaction kinetics and increased efficiency. It applies tubular enzymatic chemiluminescence with next-generation enzymatic substrates for improved sensitivity and stable luminescent signal.

Key specifications
  • Brand: BIOBASE
  • Product origin: CHINA
  • Delivery time: Within 7 days
  • Supply capacity: Factory Direct Supply
  • Model: BKI2200
  • Maximum throughput: 240 tests/hour
  • Footprint: ~0.68 m²


Advantages
  • 1. Operation Module: Tubular enzymatic chemiluminescence with magnetic particle separation; single-unit maximum speed up to 240 tests/h; carrier contamination rate <10^-5; intra-batch precision ≤8%.
  • 2. Control Module: Ergonomic layout for operator comfort; compact patented design occupying approximately 0.68 m²; supports bidirectional LIS communication and barcode scanning; integrated touchscreen and frame; real-time online loading of consumables.
  • 3. System Layout: Integrated automated layout engineered for streamlined workflow, safe sample and reagent handling, and minimized cross-contamination.
  • 4. Instrument Software Module: User-friendly software for intuitive reagent loading and sample operation; real-time sample status display; result review by sample or by project; accurate reagent usage logging per project and remaining consumable monitoring with low-consumable alarms; simple QC workflow with T-P and L-J chart support; categorized maintenance tasks (daily, monthly, yearly).


Technical Parameters
Thyroid: TSH, TT4, TT3, FT4, FT3, TgAb, TPOAb, TG, Anti-TSHR
Fertility: β-HCG, E2, P, T, PRL, FSH, LH, DHEA-S, SHBG, AMH
Hypertension: ALD, ACTH, Cortisol, Renin, AII*
Tumor markers: CA125, CA15-3, CA19-9, AFP, CEA, 1-PSA, CA72-4, SCC, CA242, CA50, NSE, CYFRA21-1, HE4, ProGRP
Cardiac markers: cTnI, NT-proBNP, CK-MB, MYO

Reagent Menu
Renal function: β2-MG
Rheumatoid: Anti-CCP
Liver fibrosis: CIV, HA, PⅢINP, LN
Anemia: FA, VB12, FERRITIN
Growth: GH, IGF-I*
Glycometabolism: INS, C-P
Pepsinogen: PGI, PGII
Inflammation: PCT, IL-6
Early screening: FE3, Free β-HCG, PAPP-A
Bone metabolism: BGP, 25-OH-Vit-D, iPTH, PINP*, CT
Infectious: HBeAb*, HBeAg*, HBcAb*, HBsAb*, HBsAg*, Anti-HBc IgM*, HIV Ag/Ab*, Anti-TP*, Anti-HCV*

Characteristics / technical specifications
  • Assay principle: Tubular enzymatic chemiluminescence with magnetic particle separation.
  • Maximum throughput: up to 240 tests/hour (depending on configuration).
  • Carrier contamination rate: <10^-5.
  • Precision: intra-batch precision ≤8%.
  • Footprint: highly integrated patented design occupying approximately 0.68 m².
  • Connectivity: supports bidirectional LIS communication and barcode scanning.
  • User interface: integrated touchscreen with intuitive sample-status display and result review.
  • Consumables management: online real-time loading, per-project reagent usage logging, remaining quantity monitoring and low-consumable alarms.
  • Quality control: easy QC addition, intuitive QC result display, support for T-P and L-J charts.
  • Maintenance: structured maintenance program with selectable daily, monthly and yearly tasks.
  • Reagent coverage: broad menu including thyroid, fertility, tumor markers, cardiac markers, renal, inflammation, liver fibrosis, anemia, growth, glycometabolism, pepsinogen, bone metabolism and infectious disease panels.

Exhibitions

Meet this supplier at the following exhibition(s):

Arablab
Arablab

26-28 Oct 2026 Dubai (United Arab Emirates)

  • More information
    Medica
    Medica

    16-19 Nov 2026 Düsseldorf (Germany)

  • More information

    Other Biobase products

    Clinical Analytical Instruments

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.