OverviewThe BK-410 automatic chemistry analyzer by BIOBASE is designed for high-volume clinical and laboratory environments, delivering up to 400 tests/hour with continuous 24-hour operation options. It combines a high sample capacity with robust reagent management and advanced QC features to support reliable diagnostic workflows.
Key Information- Brand: BIOBASE
- Product origin: CHINA
- Model: BK-410
- Delivery time: Within 7 days
- Supply capacity: Factory Direct Supply
Features- 49 sample positions for batch and STAT processing
- 56 reagent positions with 2–12℃ cooling
- 120 reusable reaction cuvettes with automatic washing
- Throughput: 400 tests/hour (ISE optional)
- Probe with anti-collision and liquid-level detection; automatic interior/exterior probe washing
- Optional open or closed system; continuous 24-hour operation
Technical ParametersModel: BK-410
Throughput: 400 tests/hour, ISE (Optional)
Analysis methods: End-point, Fixed-time, Rate (Kinetic), Turbidimetry
Certificates: CE, FDA, ISO9001, ISO14001, ISO13485
Sample positions: 49
Reagent positions: 56 (cooled 2–12℃)
Sample volume: 2–70 μl
Reagent volume: 20–350 μl
Probe: Anti-collision, liquid-level detection, automatic wash
Reaction cuvettes: 120 reusable; automatic cuvette washing
Reaction temperature control: 37±0.2℃, real-time monitoring
Optical range: 340–800 nm (±1 nm); Absorbance: 0–3.5 Abs
Calibration: Linear (K-factor, 1/2/multi-point) and non-linear (spline, polygon, logit-4P/5P etc.)
QC: Real-time QC, Westgard multi-rule, cumulative sum check, twin plot (2D)
Software: Windows 7/8/10 (32/64 bit); LIS: bi-directional, HL7 support; Interface: LAN
Power: AC220V±10% 50/60Hz (standard); 110V±10% 60Hz (optional), 650VA
Working temp/humidity: 15–30℃ (±2℃) / 40–85% RH
Water consumption: Deionized water <11 L/h
Dimensions (W×D×H): 973×645×520 mm; Net weight: 96 kg; Package: 1120×780×1035 mm, Gross 141 kg
Specifications / Technical details- Model: BK-410
- Throughput: 400 tests/hour
- Sample capacity: 49 positions
- Reagent capacity: 56 positions with cooling
- Reaction cuvettes: 120 reusable
- Sample volume range: 2–70 μl
- Reagent volume range: 20–350 μl
- Optical range: 340–800 nm (±1 nm); Abs: 0–3.5 Abs
- Reaction temp control: 37±0.2℃
- QC & calibration: Westgard, multi-point and non-linear methods
- Data & connectivity: Windows software; bi-directional LIS (HL7); LAN
- Power: AC220V±10% 50/60Hz (standard)
- Operating conditions: 15–30℃, 40–85% RH
- Dimensions & weight: 973×645×520 mm; 96 kg (net)