Product OverviewKaye ValProbe® RM is a real-time wireless datalogger system developed for temperature mapping and thermal validation applications in pharmaceutical, biotechnology, and other GxP-regulated industries. The platform combines wireless data loggers, interchangeable digital sensors, and centralized software integration within a unified validation environment.
ValProbe RM and RM-B LoggerThe ValProbe RM and RM-B are wireless, battery-powered data loggers engineered for accurate and reliable thermal validation and temperature mapping applications in GxP-regulated environments. Both logger variants support interchangeable digital sensor modules and secure real-time data acquisition while maintaining local onboard storage for redundancy.
Flexible Digital SensorsThe ValProbe RM platform supports interchangeable digital sensor modules for temperature, humidity, and other validation measurement applications. Each wireless datalogger includes dual sensor ports for flexible sensor configuration. Calibration data is stored directly within each digital sensor module, allowing sensor replacement without recalibrating the logger and preserving traceability. The system automatically recognizes sensor changes and supports electronic signature verification to maintain traceability and validation compliance.
Real-Time Wireless ArchitectureThe ValProbe RM platform utilizes a proprietary dual-antenna RF architecture operating on a 2.4 GHz wireless network. The scalable star-network architecture supports stable real-time data transmission across large validation areas and is designed to reduce communication interruptions in complex industrial environments. Each base station supports up to 50 wireless data loggers with communication ranges reaching approximately 300 meters (900 ft) line-of-sight. Multiple base stations can be integrated through Ethernet connectivity for expanded deployment flexibility. The RF architecture incorporates AES 128 encrypted communication and local data buffering; automatic reconnection capabilities help maintain study continuity during temporary connectivity interruptions.
Data Integrity and RedundancyThe ValProbe RM thermal validation system is designed to support secure data handling and uninterrupted data retention throughout qualification and mapping studies. Each wireless datalogger stores up to 100,000 samples per sensor within non-volatile memory to protect recorded data during battery replacement, temporary power interruptions, or network disruptions. The platform incorporates AES 128 encrypted communication, local data buffering, electronic signature support, and full audit trail capability to support GxP data integrity requirements. Configurable user authentication controls, tamper-resistant data management, and automatic sensor recognition with traceability features are included. When operating with external power, the system can transition to battery backup during power failures to maintain continuous data collection and gateway-level buffering with automatic reconnection further protects studies.
Features- Advanced wireless data loggers using latest RF and battery technology
- 2.4 GHz RF platform with proprietary dual-antenna communication
- One base station supports up to 50 wireless data loggers
- RF range up to 300 m (900 ft) line-of-sight
- Compact logger design with dual digital sensor ports
- Up to 100,000 stored samples per sensor in non-volatile memory
- Configurable sampling intervals starting at 10 seconds
- AES 128 encrypted data communication
- Hot-swappable digital sensors with embedded calibration data
- Automatic sensor recognition with electronic signature support
- Secure local buffering during network interruptions and data redundancy protection
- Hot-swappable dual 3.6V lithium batteries with uninterrupted operation
- Centralized software integration with ValProbe systems
- Full audit trail capability with electronic signature support
- User authentication and tamper-resistant data management
- Designed to support GxP validation requirements
- Product Variants:
- ValProbe RM – with local display
- ValProbe RM-B – display-free, cost-optimized
Applications- Environmental chambers
- Warehouses
- Cold storage (refrigerators & freezers)
- Stability testing environments
Specifications (system and logger)RF Operating Frequency: 2.4 GHz ISM band
RF Network Topology: Star topology
RF Range: Up to 300 meters line-of-sight
Data Storage: Up to 100,000 samples per sensor
Sampling Rate: Starting at 10 seconds
Transmission Rate: 10 to 30 seconds
System Capacity: 50 loggers per base station
Compliance: UL and CE
Base Station Dimensions: 190 mm x 130 mm x 55 mm (7.6 in x 5.2 in x 2.2 in)
Logger Dimensions: 118 mm (L) x 81 mm (W) x 36 mm (H)
Logger Material: ABS
Battery: Field replaceable 3.6V Lithium
Power: Hot-swappable dual 3.6V lithium batteries
Real-Time Clock Accuracy: < 10 sec/day
Calibration: NVLAP (NVLAP LAB CODE 200913-0)/DAkkS Calibration
Verification: Automated User Verification Capability
Environmental Temperature: -25°C to 60°C
Environmental Humidity: 0 to 95% non-condensing
Sensor Accuracy: Up to ±0.1°C
Temperature Range: -196°C to 130°C
Caractéristiques / spécifications techniques- Model: ValProbe RM / ValProbe RM-B
- RF frequency: 2.4 GHz ISM band
- Topology: Star network; base station supports up to 50 loggers
- RF range (line-of-sight): up to 300 m (900 ft)
- Memory: up to 100,000 samples per sensor (non-volatile)
- Sampling interval: configurable from 10 s to 10 min
- Transmission rate: 10–30 s
- Security: AES 128 encrypted communications, audit trail, eSignature support
- Sensors: Interchangeable digital sensors with embedded calibration data; dual sensor ports per logger
- Power: Hot-swappable dual 3.6V lithium batteries; field-replaceable cells
- Operating environment: -25°C to 60°C; 0–95% RH non-condensing
- Sensor accuracy: up to ±0.1°C
- Temperature measurement range: -196°C to 130°C
- Materials: ABS enclosure
- Compliance: UL, CE; NVLAP/DAkkS calibration available